Diffusion tensor imaging analysis of optic radiation using readout-segmented echo-planar imaging

被引:2
|
作者
Yamada, Hirofumi [1 ]
Yamamoto, Akira [1 ]
Okada, Tomohisa [1 ]
Kanagaki, Mitsunori [1 ]
Fushimi, Yasutaka [1 ]
Mehemed, Taha Mohamed [1 ]
Porter, David A. [2 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Diagnost Imaging & Nucl Med, Sakyo Ku, Kyoto 6068507, Japan
[2] Siemens AG, Healthcare Sect, D-91054 Erlangen, Germany
关键词
Readout-segmented echo-planar imaging; Optic radiation; Diffusion tensor imaging; Magnetic resonance imaging; WHITE-MATTER; TEMPORAL-LOBE; FIBER TRACTS; TRACTOGRAPHY; VISUALIZATION; DISSECTION; LAYERS; NERVE; MRI;
D O I
10.1007/s00276-014-1299-1
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
To investigate the diffusion tensor imaging parameters of the optic radiation and surrounding structures using the high-resolution readout-segmented diffusion tensor imaging method. Coronal readout-segmented diffusion tensor images were acquired in 15 healthy volunteers. On three slices of each image, eigenvalue 1, fractional anisotropy, radial diffusivity, apparent diffusion coefficient, and signal intensity on T2-weighted images were measured in the lateral inferior longitudinal fasciculus, external and internal layers of the optic radiation, and the tapetum within regions of interest delineated by two independent observers. Profile curve analysis of regions of interest across the optic radiation and surrounding structures was performed for a representative typical case. Significant differences in fractional anisotropy, radial diffusivity and apparent diffusion coefficient were observed between external and internal layers of the optic radiation, while there was no significant difference in eigenvalue 1. In fractional anisotropy maps, two low signal bands were observed between the inferior longitudinal fasciculus, the optic radiation and the tapetum. Profile curve analysis showed a minimum on the fractional anisotropy and eigenvalue 1 images and a maximum in the radial diffusivity image. Readout-segmented diffusion tensor imaging revealed significant differences in the diffusion tensor imaging parameters between internal and external layers of the optic radiation.
引用
收藏
页码:973 / 980
页数:8
相关论文
共 50 条
  • [41] Application value of simultaneous multislice readout-segmented echo-planar imaging for diffusion-weighted MRI in differentiation of rectal cancer grade
    Zhou, Mi
    Huang, Hongyun
    Li, Hang
    Yan, Guihua
    Tang, Baijie
    Chen, Meining
    Wang, Yuting
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2023, 36 (04) : 621 - 629
  • [42] Application value of simultaneous multislice readout-segmented echo-planar imaging for diffusion-weighted MRI in differentiation of rectal cancer grade
    Mi Zhou
    Hongyun Huang
    Hang Li
    Guihua Yan
    Baijie Tang
    Meining Chen
    Yuting Wang
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2023, 36 : 621 - 629
  • [43] Are ADC values of readout-segmented echo-planar diffusion-weighted imaging (RESOLVE) correlated with pathological prognostic factors in rectal adenocarcinoma?
    Cui Tang
    Mou-bin Lin
    Jin-lei Xu
    Lan-hua Zhang
    Xiao-ming Zuo
    Zhong-shuai Zhang
    Meng-xiao Liu
    Jin-ming Xu
    World Journal of Surgical Oncology, 16
  • [44] Comparison of Readout-Segmented and Conventional Single-Shot for Echo-Planar Diffusion-Weighted Imaging in the Assessment of Kidney Interstitial Fibrosis
    Friedli, Iris
    Crowe, Lindsey Alexandra
    de Perrot, Thomas
    Berchtold, Lena
    Martin, Pierre-Yves
    de Seigneux, Sophie
    Vallee, Jean-Paul
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) : 1631 - 1640
  • [45] Are ADC values of readout-segmented echo-planar diffusion-weighted imaging (RESOLVE) correlated with pathological prognostic factors in rectal adenocarcinoma?
    Tang, Cui
    Lin, Mou-bin
    Xu, Jin-lei
    Zhang, Lan-hua
    Zuo, Xiao-ming
    Zhang, Zhong-shuai
    Liu, Meng-xiao
    Xu, Jin-ming
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2018, 16
  • [46] Feasibility Study of 3-T DWI of the Prostate: Readout-Segmented Versus Single-Shot Echo-Planar Imaging
    Li, Liang
    Wang, Liang
    Deng, Ming
    Liu, Hui
    Cai, Jie
    Sah, Vivek Kumar
    Liu, Jihong
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (01) : 70 - 76
  • [47] The role of readout-segmented echo-planar imaging-based diffusion-weighted imaging in evaluating tumor response of locally advanced rectal cancer after neoadjuvant chemoradiotherapy
    Yang, Lanqing
    Xia, Chunchao
    Liu, Dan
    Fang, Xin
    Pan, Xuelin
    Ma, Ling
    Wu, Bing
    ACTA RADIOLOGICA, 2020, 61 (09) : 1155 - 1164
  • [48] Diffusion tensor imaging of human Achilles tendon by stimulated echo readout-segmented EPI (ste-RS-EPI)
    Wengler, Kenneth
    Tank, Dharmesh
    Fukuda, Takeshi
    Paci, James M.
    Huang, Mingqian
    Schweitzer, Mark E.
    He, Xiang
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2464 - 2474
  • [49] Optimization of Simultaneous Multislice, Readout-Segmented Echo Planar Imaging for Accelerated Diffusion-Weighted Imaging of the Head and Neck: A Preliminary Study
    Su, Tong
    Chen, Yu
    Zhang, Zhuhua
    Zhu, Jinxia
    Liu, Wei
    Chen, Xingming
    Zhang, Tao
    Zhu, Xiaoli
    Qian, Tianyi
    Xu, Zhentan
    Xue, Huadan
    Jin, Zhengyu
    ACADEMIC RADIOLOGY, 2020, 27 (11) : E245 - E253
  • [50] Differentiating Neuromyelitis Optica-Related and Multiple Sclerosis-Related Acute Optic Neuritis Using Conventional Magnetic Resonance Imaging Combined With Readout-Segmented Echo-Planar Diffusion-Weighted Imaging
    Lu, Ping
    Tian, Guohong
    Liu, Xilan
    Wang, Feng
    Zhang, Zhongshuai
    Sha, Yan
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (04) : 502 - 509