Status of PM in Seoul metropolitan subway cabins and effectiveness of subway cabin air purifier (SCAP)

被引:29
作者
Kim, Jong-Bum [1 ,2 ]
Kim, Seyoung [2 ,3 ]
Lee, Gwang-Jae [1 ,2 ]
Bae, Gwi-Nam [1 ]
Cho, Youngmin [2 ]
Park, Duckshin [2 ]
Lee, Duck-Hee [2 ]
Kwon, Soon-Bark [2 ]
机构
[1] Korea Inst Sci & Technol, Ctr Environm Hlth & Welf Res, Seoul, South Korea
[2] KRRI, Ecotransport Syst Res Dept, Uiwang, South Korea
[3] Kanazawa Univ, Dept Chem & Mat Engn, Kanazawa, Ishikawa, Japan
关键词
Subway cabin air purifier (SCAP); Indoor air quality (IAQ); Subway cabin; Particulate matter (PM); PM10; PM2.5; PUBLIC TRANSPORTATION MODES; PARTICULATE MATTER PM10; ELEMENTAL COMPOSITION; OXIDATIVE STRESS; PM2.5; EXPOSURE; POLLUTION; PARTICLES; QUALITY; LONDON;
D O I
10.1007/s10098-013-0708-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The increasing importance of indoor air quality management on public transport led the Korean government to amend the indoor air quality control in public use facilities, etc. Act including modes of public transport under the Act from June 2013. Particulate matter (PM) in subway systems is reported as being mostly generated by friction-between the wheels and the rails, between the wheels and the brake pads, and between the catenaries and the pantographs. In order to reduce PM level in subway cabins, a newly developed subway cabin air purifier (SCAP) was installed on the ceilings of the cabins. In this study, we analyzed indoor PM concentrations through continuous measurement of PMs less than 10 mu m in diameter (PM10) and PMs less than 2.5 mu m in diameter (PM2.5) in the cabins of line 2 and line 5 of the Seoul metropolitan subway network, comparing the concentrations in cabins where SCAP devices were installed to cabins without them in order to verify SCAP effectiveness. In both cabins with and without SCAP, the ratio of indoor to outdoor PM10 (I/O for PM10) showed a two-times higher value in line 5 than in line 2, which indicated that the entirely underground line 5 was less ventilated with outdoor air. In addition, the ratio of indoor PM2.5/PM10 showed that coarse mode PM was more abundant in line 5 due to poor ventilation in the tunnel sections compared to that of line 2. Regarding the effectiveness of SCAP, it was found that changes of PM10 concentrations in line 2 and line 5 were from 132.8 to 112.2 mu g/m(3) (15.5 % efficiency) and from 154.4 to 114.2 mu g/m(3) (26.0 % efficiency) after SCAP installation, respectively.
引用
收藏
页码:1193 / 1200
页数:8
相关论文
共 35 条
[11]   Particulate matter concentrations, physical characteristics and elemental composition in the Milan underground transport system [J].
Colombi, C. ;
Angius, S. ;
Gianelle, V. ;
Lazzarini, M. .
ATMOSPHERIC ENVIRONMENT, 2013, 70 :166-178
[12]   Polycyclic aromatic hydrocarbons (PAH) and diesel engine emission (elemental carbon) inside a car and a subway train [J].
Fromme, H ;
Oddoy, A ;
Piloty, M ;
Krause, M ;
Lahrz, T .
SCIENCE OF THE TOTAL ENVIRONMENT, 1998, 217 (1-2) :165-173
[13]   Bus, minibus, metro inter-comparison of commuters' exposure to air pollution in Mexico City [J].
Gomez-Perales, J. E. ;
Colvile, R. N. ;
Fernandez-Bremauntz, A. A. ;
Gutierrez-Avedoy, V. ;
Paramo-Figueroa, V. H. ;
Blanco-Jimenez, S. ;
Bueno-Lopez, E. ;
Bernabe-Cabanillas, R. ;
Mandujano, F. ;
Hidalgo-Navarro, M. ;
Nieuwenhuijsen, M. J. .
ATMOSPHERIC ENVIRONMENT, 2007, 41 (04) :890-901
[14]   Chemical speciation of size-segregated floor dusts and airborne magnetic particles collected at underground subway stations in Seoul, Korea [J].
Jung, Hae-Jin ;
Kim, BoWha ;
Malek, Md Abdul ;
Koo, Yong Sung ;
Jung, Jong Hoon ;
Son, Youn-Suk ;
Kim, Jo-Chun ;
Kim, HyeKyoung ;
Ro, Chul-Un .
JOURNAL OF HAZARDOUS MATERIALS, 2012, 213 :331-340
[15]   Source identification of particulate matter collected at underground subway stations in Seoul, Korea using quantitative single-particle analysis [J].
Jung, Hae-Jin ;
Kim, BoWha ;
Ryu, JiYeon ;
Maskey, Shila ;
Kim, Jo-Chun ;
Sohn, Jongryeul ;
Ro, Chul-Un .
ATMOSPHERIC ENVIRONMENT, 2010, 44 (19) :2287-2293
[16]   Genotoxic effects and oxidative stress induced by organic extracts of particulate matter (PM10) collected from a subway tunnel in Seoul, Korea [J].
Jung, Mi Hyun ;
Kim, Ha Ryong ;
Park, Yong Joo ;
Park, Duck Shin ;
Chung, Kyu Hyuck ;
Oh, Seung Min .
MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2012, 749 (1-2) :39-47
[17]   Particulate matter (PM) concentrations in underground and ground-level rail systems of the Los Angeles Metro [J].
Kam, Winnie ;
Cheung, Kalam ;
Daher, Nancy ;
Sioutas, Constantinos .
ATMOSPHERIC ENVIRONMENT, 2011, 45 (08) :1506-1516
[18]   Subway particles are more genotoxic than street particles and induce oxidative stress in cultured human lung cells [J].
Karlsson, HL ;
Nilsson, L ;
Möller, L .
CHEMICAL RESEARCH IN TOXICOLOGY, 2005, 18 (01) :19-23
[19]   Spatial distribution of particulate matter (PM10 and PM2.5) in Seoul Metropolitan Subway stations [J].
Kim, Ki Youn ;
Kim, Yoon Shin ;
Roh, Young Man ;
Lee, Cheol Min ;
Kim, Chi Nyon .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 154 (1-3) :440-443
[20]   A noticeable shift in particulate matter levels after platform screen door installation in a Korean subway station [J].
Kim, Ki-Hyun ;
Ho, Duy Xuan ;
Jeon, Jae-Sik ;
Kim, Jo-Chun .
ATMOSPHERIC ENVIRONMENT, 2012, 49 :219-223