The increasing importance of indoor air quality management on public transport led the Korean government to amend the indoor air quality control in public use facilities, etc. Act including modes of public transport under the Act from June 2013. Particulate matter (PM) in subway systems is reported as being mostly generated by friction-between the wheels and the rails, between the wheels and the brake pads, and between the catenaries and the pantographs. In order to reduce PM level in subway cabins, a newly developed subway cabin air purifier (SCAP) was installed on the ceilings of the cabins. In this study, we analyzed indoor PM concentrations through continuous measurement of PMs less than 10 mu m in diameter (PM10) and PMs less than 2.5 mu m in diameter (PM2.5) in the cabins of line 2 and line 5 of the Seoul metropolitan subway network, comparing the concentrations in cabins where SCAP devices were installed to cabins without them in order to verify SCAP effectiveness. In both cabins with and without SCAP, the ratio of indoor to outdoor PM10 (I/O for PM10) showed a two-times higher value in line 5 than in line 2, which indicated that the entirely underground line 5 was less ventilated with outdoor air. In addition, the ratio of indoor PM2.5/PM10 showed that coarse mode PM was more abundant in line 5 due to poor ventilation in the tunnel sections compared to that of line 2. Regarding the effectiveness of SCAP, it was found that changes of PM10 concentrations in line 2 and line 5 were from 132.8 to 112.2 mu g/m(3) (15.5 % efficiency) and from 154.4 to 114.2 mu g/m(3) (26.0 % efficiency) after SCAP installation, respectively.
引用
收藏
页码:1193 / 1200
页数:8
相关论文
共 35 条
[1]   The concentrations and composition of and exposure to fine particles (PM2.5) in the Helsinki subway system [J].
Aarnio, P ;
Yli-Tuomi, T ;
Kousa, A ;
Mäkelä, T ;
Hirsikko, A ;
Hämeri, K ;
Räisänen, M ;
Hillamo, R ;
Koskentalo, T ;
Jantunen, M .
ATMOSPHERIC ENVIRONMENT, 2005, 39 (28) :5059-5066
[2]   Fine particle (PM2.5) personal exposure levels in transport microenvironments, London, UK [J].
Adams, HS ;
Nieuwenhuijsen, MJ ;
Colvile, RN ;
McMullen, MAS ;
Khandelwal, P .
SCIENCE OF THE TOTAL ENVIRONMENT, 2001, 279 (1-3) :29-44
[3]  
Air Korea, 2011, REAL TIM AIR QUAL
[4]   Indoor air quality in a metropolitan area metro using fuzzy logic assessment system [J].
Assimakopoulos, M. N. ;
Dounis, A. ;
Spanou, A. ;
Santamouris, M. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2013, 449 :461-469
[5]   The contribution of ambient sources to particulate pollution in spaces and trains of the Prague underground transport system [J].
Branis, M .
ATMOSPHERIC ENVIRONMENT, 2006, 40 (02) :348-356
[6]  
권순박, 2011, [JOURNAL OF THE KOREAN SOCIETY FOR RAILWAY, 한국철도학회논문집], V14, P313
[7]   Commuter exposure to particulate matter in public transportation modes in Hong Kong [J].
Chan, LY ;
Lau, WL ;
Lee, SC ;
Chan, CY .
ATMOSPHERIC ENVIRONMENT, 2002, 36 (21) :3363-3373
[8]   Exposure level of carbon monoxide and respirable suspended particulate in public transportation modes while commuting in urban, area of Guangzhou, China [J].
Chan, LY ;
Lau, WL ;
Zou, SC ;
Cao, ZX ;
Lai, SC .
ATMOSPHERIC ENVIRONMENT, 2002, 36 (38) :5831-5840
[9]   Levels of PM10 and PM2.5 in Taipei Rapid Transit System [J].
Cheng, Yu-Hsiang ;
Lin, Yi-Lun ;
Liu, Chia-Chen .
ATMOSPHERIC ENVIRONMENT, 2008, 42 (31) :7242-7249
[10]   Elevated airborne exposures of teenagers to manganese, chromium, and iron from steel dust and New York City's subway system [J].
Chillrud, SN ;
Epstein, D ;
Ross, JM ;
Sax, SN ;
Pederson, D ;
Spengler, JD ;
Kinney, PL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (03) :732-737