Two novel pulse sequences, CALIS-1 and CALIS-2, for accurate calibration of the RF field strength for an indirectly observed spin are introduced. CALIS-2 is intended for calibration of e.g., C-13 or N-15 pulses on natural abundance samples whilst CALIS-1 is recommended primarily for enriched samples. Both experiments can be performed without prior knowledge or guess of the RF field strength and no delays in the pulse sequences are critically dependent on coupling constants. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:317 / 320
页数:4
相关论文
共 50 条
  • [11] RF field strength control and an envelope detector
    Lusk, Greg
    Gullion, Terry
    MAGNETIC RESONANCE IN CHEMISTRY, 2020, 58 (11) : 1071 - 1075
  • [12] Performance Evaluation of CoMP Methods under RF Calibration Errors
    Khashaba, Amr
    Sadek, Mirette
    El-Ramly, Salwa
    2016 INTERNATIONAL CONFERENCE ON SELECTED TOPICS IN MOBILE & WIRELESS NETWORKING (MOWNET), 2016, : 247 - 253
  • [13] Influence of Calibration Methods and RF Probes on the RF Characterization of 28FD-SOI MOSFET
    Pradeep, Karthi
    Deng, Marina
    Dormieu, Benjamin
    Scheer, Patrick
    De Matos, Magali
    Zimmer, Thomas
    Fregonese, Sebastien
    2021 IEEE LATIN AMERICA ELECTRON DEVICES CONFERENCE (LAEDC), 2021,
  • [14] A GUIDE TO ARCHAEOLOGICAL FIELD METHODS - HEIZER,RF
    SPAULDING, AC
    AMERICAN ANTIQUITY, 1959, 24 (04) : 434 - 434
  • [15] Spin resonance strength of a localized rf magnetic field
    Lee, S. Y.
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2006, 9 (07):
  • [17] New Calibration Methods with Asymmetric Data
    Kim, Sungsu
    KOREAN JOURNAL OF APPLIED STATISTICS, 2010, 23 (04) : 759 - 765
  • [18] NEW CALIBRATION METHODS FOR INDUSTRIAL ROBOTS
    JANOCHA, H
    DIEWALD, B
    VONHINUBER, E
    FORSCHUNG IM INGENIEURWESEN-ENGINEERING RESEARCH, 1993, 59 (06): : 110 - 115
  • [19] About the development of a calibration laboratory for RF electromagnetic field probes and monitors
    Marinescu, Andrei
    Scornea, Aurelia
    OPTIM 04: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, VOL I: ELECTROTECHNICS, 2004, : 79 - 84
  • [20] Influence of different methods of cleaning custom bases on the shear bond strength of indirectly bonded brackets
    Kanashiro, Lylian K.
    Robles-Ruiz, Julissa J.
    Ciamponi, Ana L.
    Medeiros, Igor S.
    Tortamano, Andre
    Paiva, Joao B.
    JOURNAL OF ORTHODONTICS, 2014, 41 (03) : 175 - 180