New methods for calibration of the RF field strength for indirectly observed

被引:3
|
作者
Benie, Andrew J. [1 ]
Sorensen, Ole W. [1 ]
机构
[1] Carlsberg Lab, DK-2500 Copenhagen, Denmark
关键词
NMR; pulse calibration; CALIS;
D O I
10.1016/j.jmr.2006.03.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two novel pulse sequences, CALIS-1 and CALIS-2, for accurate calibration of the RF field strength for an indirectly observed spin are introduced. CALIS-2 is intended for calibration of e.g., C-13 or N-15 pulses on natural abundance samples whilst CALIS-1 is recommended primarily for enriched samples. Both experiments can be performed without prior knowledge or guess of the RF field strength and no delays in the pulse sequences are critically dependent on coupling constants. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:317 / 320
页数:4
相关论文
共 50 条
  • [1] 2CALIS doubling the sensitivity of CALIS for calibration of the rf field strength for indirectly observed nuclei
    Benie, Andrew J.
    Sorensen, Ole W.
    JOURNAL OF MAGNETIC RESONANCE, 2006, 182 (02) : 348 - 352
  • [2] CALIBRATION OF RF FIELD-STRENGTH METERS
    DEVREEDE, JPM
    TEUNISSE, GM
    MUNTER, K
    HOITINK, H
    HOLLAND, K
    ODWYER, M
    BERGSTEN, L
    PURANEN, L
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (02) : 351 - 354
  • [3] Measurement methods for a new RF and microwave calibration source
    Roberts, Paul C. A.
    Electronics World, 2007, 113 (1852): : 28 - 31
  • [4] Measurement methods for a new RF and microwave calibration source
    Roberts, Paul C. A.
    ELECTRONICS WORLD, 2007, 113 (1852): : 28 - 31
  • [5] New method for RF field amplitude and phase calibration in FLASH accelerator
    Pawlik, P.
    Grecki, M.
    Simrock, S.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2006, : 85 - +
  • [6] Characteristics, calibration and measurement uncertainty of RF field strength meters in the frequency range up to 18 GHz
    Pape, R.
    Muenter, K.
    Schrader, T.
    ADVANCES IN RADIO SCIENCE, 2007, 5 (435-438) : 435 - 438
  • [7] Antenna field calibration laboratory for RF electromagnetic field meters
    Marinescu, A
    Scornea, A
    Dumbrava, I
    Mihai, G
    Glimm, J
    Münter, K
    Pape, R
    2003 IEEE International Symposium on Electromagnetic Compatibility (EMC), Vols 1 and 2, Symposium Record, 2003, : 112 - 114
  • [8] PULSE METHODS FOR CALIBRATION OF THE DECOUPLER RADIOFREQUENCY FIELD-STRENGTH IN NMR-SPECTROSCOPY
    SKLENAR, V
    NEJEZCHLEB, K
    STARCUK, Z
    JOURNAL OF MAGNETIC RESONANCE, 1986, 69 (01) : 144 - 150
  • [9] Handheld analyzer checks RF field strength
    不详
    MICROWAVES & RF, 1998, 37 (04) : 172 - 172
  • [10] OBSERVED FIELD STRENGTH IN NEIGHBORHOOD OF SKIP DISTANCE
    YEH, KC
    SWENSON, GW
    JOURNAL OF GEOPHYSICAL RESEARCH, 1961, 66 (02): : 654 - &