A Robust Camera-Based Method for Optical Distortion Calibration of Head-Mounted Displays

被引:25
作者
Lee, Sangyoon [1 ]
Hua, Hong [1 ]
机构
[1] Univ Arizona, Coll Opt Sci, Tucson, AZ 85721 USA
来源
JOURNAL OF DISPLAY TECHNOLOGY | 2015年 / 11卷 / 10期
基金
美国国家科学基金会;
关键词
Geometric calibration; head-mounted display (HMD); optical distortion; photogrammetry; MODELS;
D O I
10.1109/JDT.2014.2386216
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
One of the problems in using HMDs is that the virtual images shown through the HMDs are usually warped due to their optical distortions. In order to correctly compensate the optical distortions through a predistortion technique, accurate values of the distortion parameters are required. Although several distortion calibration methods have been developed in prior work, these methods have some limitations. In this paper, we propose a method for accurately estimating the optical distortion parameters of both immersive and (optical) see-through HMDs, without the limitations. The proposed method is based on photogrammetry and considers not only the radial distortion but also the tangential distortion. Its effectiveness, including the effects of different coefficient orders of radial and tangential distortions, are evaluated through an experiment conducted with two different HMDs, an optical see-through head-mounted projection display (HMPD) and a commercially available immersive HMD. According to the experimental results, the proposed method showed significantly lower reprojection and line-fitting errors than a previous method proposed by Owen et al., and the radial distortion coefficients estimated by the proposed method were significantly more accurate than the nominal values obtained from the HMD optics prescription. In addition, when both the radial and tangential distortions were considered, the proposed method was significantly more effective than when only the radial distortion was considered. We also discuss an OpenCV-based simple implementation of a distortion correction method.
引用
收藏
页码:845 / 853
页数:9
相关论文
共 19 条
  • [1] [Anonymous], 1966, Photogrammetric Engineering and Remote Sensing
  • [2] BAX MR, 2004, STANFORD ELECT E SPR, P9, DOI DOI 10.1109/ITSC.2003.1252685
  • [3] BROWN DC, 1971, PHOTOGRAMM ENG, V37, P855
  • [4] Spatial calibration of an optical see-through head-mounted display
    Gilson, Stuart J.
    Fitzgibbon, Andrew W.
    Glennerster, Andrew
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2008, 173 (01) : 140 - 146
  • [5] Howlett E.M., 1983, U.S. Patent, Patent No. [4406532A, 4406532]
  • [6] Calibration of a head-mounted projective display for augmented reality systems
    Hua, H
    Gao, CY
    Ahuja, N
    [J]. INTERNATIONAL SYMPOSIUM ON MIXED AND AUGMENTED REALITY, PROCEEDINGS, 2002, : 176 - 185
  • [7] Geometric Calibration of Head-Mounted Displays and its Effects on Distance Estimation
    Kellner, Falko
    Bolte, Benjamin
    Bruder, Gerd
    Rautenberg, Ulrich
    Steinicke, Frank
    Lappe, Markus
    Koch, Reinhard
    [J]. IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2012, 18 (04) : 589 - 596
  • [8] HMD Calibration and Its Effects on Distance Judgments
    Kuhl, Scott A.
    Thompson, William B.
    Creem-Regehr, Sarah H.
    [J]. ACM TRANSACTIONS ON APPLIED PERCEPTION, 2009, 6 (03)
  • [9] Lee S, 2013, P IEEE VIRT REAL ANN, P27, DOI 10.1109/VR.2013.6549353
  • [10] Melzer J.E., 2009, HELMET MOUNTED DISPL, P805