Chemical induced demineralization study in cortical bone

被引:3
|
作者
Sales, E. [1 ,3 ]
da Silva, C. E. R. [2 ]
Letichevsky, S. [3 ]
dos Santos, R. [1 ]
Leitao, R. [1 ]
dos Santos, C. T. [2 ]
de Oliveira, L. F. [1 ]
de Avillez, R. [3 ]
Monteiro, M. [2 ]
Costa-Felix, R. [4 ]
Paciornik, S. [3 ]
dos Anjos, M. [1 ]
机构
[1] Rio De Janeiro State Univ UERJ, Dept Appl Phys & Thermodynam, 524 Sao Francisco Xavier St, Rio De Janeiro, Brazil
[2] Natl Inst Technol INT, Div Mat & Prod Testing, 82 Venezuela Ave, Rio De Janeiro, Brazil
[3] Pontifical Catholic Univ Rio De Janeiro PUC Rio, Dept Chem & Mat Engn, 255 Marques Sao Vicente St, Rio De Janeiro, Brazil
[4] Natl Inst Metrol Qual & Technol INMETRO, Lab Ultrasound, 50 Nossa Senhora Gracas Ave, Duque De Caxias, Brazil
来源
JOURNAL OF INSTRUMENTATION | 2018年 / 13卷
关键词
X-ray diffraction detectors; X-ray fluorescence (XRF) systems; HYDROXYAPATITE CRYSTALLITE ORIENTATION;
D O I
10.1088/1748-0221/13/05/C05010
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this work we present a study of demineralization in bovine cortical bone. We selected 9 fresh cortical bone samples from 2 diaphyseal femurs for analysis. Sampleswere demineralized for 24 h, 48 h, 72 h and 96 h using two concentrations of EDTA with different pH: EDTA 0.1M(pH 10, alkaline) and EDTA 0.5M(pH 7.4, neutral). We have employed mu-X-ray fluorescence (mu-XRF) and X- ray diffraction (XRD) to assess the degree of demineralization. EDTA solutions were analyzed for Calcium (Ca) and Phosphorous (P) extractions by Atomic Absorption Spectrophotometry (AAS) and Ion Chromatography (IC), respectively. Results from AAS and IC showed that EDTA 0.5M (pH 7.4) removed two times more Ca and 3 times more P than EDTA 0.1M (pH 10) in the first 24 hours. mu-XRF results presented that EDTA has a high capacity to bind Calcium and Phosphorus. On the other hand, despite the differences in concentration and pH, EDTA did not bind Zn and Sr. Results from XRD showed that EDTA with high concentration had a greater impact to the samples' crystallinity causing a severe damage.
引用
收藏
页数:7
相关论文
共 5 条
  • [1] Simulation study of axial ultrasound transmission in heterogeneous cortical bone model
    Takano, Koki
    Nagatani, Yoshiki
    Matsukawa, Mami
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2017, 56 (07)
  • [2] Simulation study of axial ultrasonic wave propagation in heterogeneous bovine cortical bone
    Hata, Toshiho
    Nagatani, Yoshiki
    Takano, Koki
    Matsukawa, Mami
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2016, 140 (05) : 3710 - 3717
  • [3] Simulation of ultrasonically induced electrical potentials in bone
    Suzuyama, Hidehisa
    Tsubata, Taisei
    Kitajima, Shouta
    Maehara, Keigo
    Hosokawa, Atsushi
    Tsuchiya, Takao
    Matsukawa, Mami
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 154 (02) : 1315 - 1323
  • [4] Inter-individual changes in cortical bone three-dimensional microstructure and elastic coefficient have opposite effects on radial sound speed
    Eneh, Chibuzor T. M.
    Liukkonen, Jukka
    Malo, Markus K. H.
    Jurvelin, Jukka S.
    Toyras, Juha
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2015, 138 (06) : 3491 - 3499
  • [5] Effect of anisotropy on stress-induced electrical potentials in bovine bone using ultrasound irradiation
    Matsukawa, S.
    Makino, T.
    Mori, S.
    Koyama, D.
    Takayanagi, S.
    Mizuno, K.
    Yanagitani, T.
    Matsukawa, M.
    APPLIED PHYSICS LETTERS, 2017, 110 (14)