Effect of Spectral Domain Optical Coherence Tomography Image Quality on Macular Thickness Measurements and Error Rate

被引:5
作者
Falavarjani, Khalil Ghasemi [1 ]
Mehrpuya, Amirabbas [2 ]
Amirkourjani, Foad [2 ]
机构
[1] Iran Univ Med Sci, Rassoul Akram Hosp, Dept Ophthalmol, Eye Res Ctr, Tehran, Iran
[2] Iran Univ Med Sci, Rassoul Akram Hosp, Eye Res Ctr, Tehran, Iran
关键词
Artifact; Image quality; Optical coherence tomography; RETINAL THICKNESS; SEGMENTATION ERROR; CATARACT-SURGERY; SIGNAL STRENGTH; INSTRUMENTS; DENSITY; DEVICES; MEDIA;
D O I
10.1080/02713683.2016.1179332
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the effect of Topcon spectral domain optical coherence tomography (OCT) image quality on macular thickness measurements and the error rate in healthy subjects and patients with clinically significant diabetic macular edema (CSME).Methods: In this prospective, comparative case series, macular thickness measurements, and the rate of decentration and segmentation errors were evaluated before and after reducing the image quality factor (QF). The measurements were evaluated again after correcting the decentration and segmentation errors. To reduce the image QF below 45, tetracycline eye ointment was applied on the corneal surface.Results: Forty eyes of 40 subjects including 18 healthy eyes and 22 eyes with CSME were included. In both groups, the difference in central subfield thickness measurements before and after reducing the image QF was not statistically significant both before and after error correction (all P>0.05). The rate of decentration error was statistically similar before and after reducing image QF in normal and CSME eyes (P=0.50, P=0.69, respectively). However, the rate of segmentation error was statistically significantly higher after reducing image QF both in normal and CSME eyes (P=0.008 and P=0.004, respectively). In both groups, eyes with a segmentation error had higher image QF reduction (both P=0.01).Conclusion: Reducing image quality results in a higher rate of the segmentation error in normal eyes and in eyes with CSME.
引用
收藏
页码:282 / 286
页数:5
相关论文
共 27 条
[1]   Influence of cataract surgery on repeatability and measurements of spectral domain optical coherence tomography [J].
Bambo, Maria P. ;
Garcia-Martin, Elena ;
Otin, Sofia ;
Sancho, Eva ;
Fuertes, Isabel ;
Herrero, Raquel ;
Satue, Maria ;
Pablo, Luis .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (01) :52-58
[2]   Comparison of Retinal Nerve Fiber Layer Thickness Measurement Bias and Imprecision across Three Spectral-Domain Optical Coherence Tomography Devices [J].
Buchser, Nancy M. ;
Wollstein, Gadi ;
Ishikawa, Hiroshi ;
Bilonick, Richard A. ;
Ling, Yun ;
Folio, Lindsey S. ;
Kagemann, Larry ;
Noecker, Robert J. ;
Albeiruti, Eiyass ;
Schuman, Joel S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (07) :3742-3747
[3]   Influence of Pseudophakic Lens Capsule Opacification on Spectral Domain and Time Domain Optical Coherence Tomography Image Quality [J].
Cagini, Carlo ;
Pietrolucci, Francesca ;
Lupidi, Marco ;
Messina, Marco ;
Piccinelli, Francesco ;
Fiore, Tito .
CURRENT EYE RESEARCH, 2015, 40 (06) :579-584
[4]   Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography [J].
Cheung, Carol Yim Lui ;
Leung, Christopher Kai Shun ;
Lin, Dusheung ;
Pang, Chi-Pui ;
Lam, Dennis Shun Chiu .
OPHTHALMOLOGY, 2008, 115 (08) :1347-1351
[5]   Optical density filters modeling media opacities cause decreased SD-OCT retinal layer thickness measurements with inter- and intra-individual variation [J].
Darma, Stanley ;
Kok, Pauline H. B. ;
van den Berg, Thomas J. T. P. ;
Abramoff, Michael D. ;
Faber, Dirk J. ;
Hulsman, Caroline A. ;
Zantvoord, Frank ;
Mourits, Maarten P. ;
Schlingemann, Reinier O. ;
Verbraak, Frank D. .
ACTA OPHTHALMOLOGICA, 2015, 93 (04) :355-361
[6]   Macular thickness measurement in clinically significant macular edema before and after meal [J].
Falavarjani, Khalil Ghasemi ;
Khadamy, Joobin ;
Amirkourjani, Foad ;
Safi, Hamid ;
Modarres, Mehdi .
JOURNAL OF CURRENT OPHTHALMOLOGY, 2015, 27 (3-4) :125-128
[7]   Effect of grid decentration on macular thickness measurements in normal subjects and patients with diabetic macular edema [J].
Falavarjani, Khalil Ghasemi ;
Khadamy, Joobin ;
Safi, Hamid ;
Karimi, Nasser ;
Amirkourjani, Foad .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2015, 25 (03) :218-221
[8]   Variation in optical coherence tomography signal quality as an indicator of retinal nerve fibre layer segmentation error [J].
Folio, Lindsey S. ;
Wollstein, Gadi ;
Ishikawa, Hiroshi ;
Bilonick, Richard A. ;
Ling, Yun ;
Kagemann, Larry ;
Noecker, Robert J. ;
Fujimoto, James G. ;
Schuman, Joel S. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (04) :514-518
[9]   Macular thickness changes evaluated with spectral domain optical coherence tomography after uncomplicated phacoemulsification [J].
Gharbiya, M. ;
Cruciani, F. ;
Cuozzo, G. ;
Parisi, F. ;
Russo, P. ;
Abdolrahimzadeh, S. .
EYE, 2013, 27 (05) :605-611
[10]   Comparison of manually corrected retinal thickness measurements from multiple spectral-domain optical coherence tomography instruments [J].
Heussen, Florian M. ;
Ouyang, Yanling ;
McDonnell, Emma C. ;
Narala, Ramsudha ;
Ruiz-Garcia, Humberto ;
Walsh, Alexander C. ;
Sadda, SriniVas R. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (03) :380-385