Analysis of intron 13 microsatellite repeat polymorphism of the factor VIII gene by capillary electrophoresis

被引:5
作者
Sumita, C [1 ]
Suehiro, A [1 ]
Sawada, A [1 ]
Higasa, S [1 ]
Ueda, M [1 ]
Kakishita, E [1 ]
机构
[1] Hyogo Coll Med, Dept Internal Med 2, Nishinomiya, Hyogo 663, Japan
关键词
factor VIII gene; microsatellite repeat polymorphism (MRP); PCR; capillary electrophoresis (CE);
D O I
10.1055/s-2000-9809
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To establish a rapid and automatic gene analysis method, we used capillary electrophoresis (CE) for the analysis of the intron 13 microsatellite repeat polymorphism (MRP) of the coagulation factor VIII gene for the diagnosis of hemophilia A. In the analysis of a 20-bp DNA ladder marker, the reproducibility evaluated using the relative standard deviation (RSD) of the relative migration time for one fragment of each fragment were less than 0.01%, whereas the RSDs of the actual migration time of each fragment were 0.1-0.3%. Thus, the appropriate internal standard should be mixed with the sample when CE resolves polymerase chain reaction (PCR) products. We next analyzed the intron 13 MRP evaluated with (CA), repeats of the factor VIII gene using a 200-bp DNA fragment as the internal standard. The results showed that the PCR products from the intron 13 MRP could be resolved using CE, even with the repeat numbers of 20 and 21, which differ by only 2 bp. These results suggest that CE is a suitable method for analyzing PCR products for gene diagnosis.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 12 条
[1]   Automated polymerase chain reaction product sample preparation for capillary electrophoresis analysis [J].
Belgrader, P ;
Devaney, JM ;
DelRio, SA ;
Turner, KA ;
Weaver, KR ;
Marino, MA .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 683 (01) :109-114
[2]   Feasibility of prenatal diagnosis and carrier detection in South African haemophilia A patients [J].
Dangerfield, BTF ;
Manga, P ;
Field, SP ;
Hartman, E ;
Jenkins, T ;
Krause, A .
BRITISH JOURNAL OF HAEMATOLOGY, 1997, 97 (03) :558-560
[3]  
LALLOZ MRA, 1994, BRIT J HAEMATOL, V86, P804
[4]   High-throughput analysis of fragile X (CGG)(n) alleles in the normal and premutation range by PCR amplification and automated capillary electrophoresis [J].
Larsen, LA ;
Gronskov, K ;
NorgaardPedersen, B ;
BrondumNielsen, K ;
Hasholt, L ;
Vuust, J .
HUMAN GENETICS, 1997, 100 (5-6) :564-568
[5]  
OTO M, 1995, CLIN CHEM, V41, P482
[6]  
PEAKE I, 1995, THROMB HAEMOSTASIS, V74, P40
[7]   Analysis of single-strand conformation polymorphism by capillary electrophoresis with laser-induced fluorescence detection using short-chain polyacrylamide as sieving medium [J].
Ren, JC ;
Ulvik, A ;
Ueland, PM ;
Refsum, H .
ANALYTICAL BIOCHEMISTRY, 1997, 245 (01) :79-84
[8]  
SUEHIRO K, 1988, J LAB CLIN MED, V112, P314
[9]   COMPARATIVE-STUDY OF NONPOROUS ANION-EXCHANGE CHROMATOGRAPHY, CAPILLARY GEL-ELECTROPHORESIS AND CAPILLARY ELECTROPHORESIS IN POLYMER-SOLUTIONS IN THE SEPARATION OF DNA RESTRICTION FRAGMENTS [J].
SUMITA, C ;
BABA, Y ;
HIDE, K ;
ISHIMARU, N ;
SAMATA, K ;
TANAKA, A ;
TSUHAKO, M .
JOURNAL OF CHROMATOGRAPHY A, 1994, 661 (1-2) :297-303
[10]  
Sumita C, 1999, CHEM PHARM BULL, V47, P111