Study of φ→π+π-π0 with CMD-2 detector

被引:53
|
作者
Akhmetshin, R. R.
Aulchenko, V. M.
Banzarov, V. Sh.
Barkov, L. M.
Bashtovoy, N. S.
Bondar, A. E.
Bondarev, D. V.
Bragin, A. V.
Eidelman, S. I.
Epifanov, D. A. [1 ]
Fedotovich, G. V.
Gabyshev, N. I.
Gorbachev, D. A.
Grebeniuk, A. A.
Grigoriev, D. N.
Ignatov, F. V.
Karpov, S. V.
Kazanin, V. F.
Khazin, B. I.
Koop, I. A.
Krokovny, P. P.
Kuzmin, A. S.
Logashenko, I. B.
Lukin, P. A.
Lysenko, A. P.
Mikhailov, K. Yu.
Milstein, A. I.
Nesterenko, I. N.
Nikulin, M. A.
Okhapkin, V. S.
Otboev, A. V.
Perevedentsev, E. A.
Popov, A. S.
Redin, S. I.
Root, N. I.
Ruban, A. A.
Ryskulov, N. M.
Shatunov, Yu. M.
Shwartz, B. A.
Sibidanov, A. L.
Sidorov, V. A.
Skrinsky, A. N.
Smakhtin, V. P.
Snopkov, I. G.
Solodov, E. P.
Yudin, Yu. V.
Zaitsev, A. S.
Zverev, S. G.
机构
[1] Russian Acad Sci, Budker Inst Nucl Phys, Siberian Div, Novosibirsk 630090, Russia
[2] Novosibirsk State Univ, Novosibirsk 630090, Russia
[3] Boston Univ, Boston, MA 02215 USA
[4] Weizmann Inst Sci, IL-76100 Rehovot, Israel
关键词
D O I
10.1016/j.physletb.2006.09.041
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The cross section of the process e(+)e(-) -> pi(+)pi(-)pi(0) has been measured in the c.m. energy range 984-1060 MeV with the CMD-2 detector at the VEPP-2M collider. The obtained value of Br(phi -> e(+)e(-))Br(phi -> pi(+)pi(-)pi(0)) = (4.51 +/- 0.16 +/- 0.11) x 10(-5) is in good agreement with the previous measurements and has the best accuracy. Analysis of the Dalitz plot was performed. The contributions of the dominant phi ->rho pi mechanism as well as of a small direct phi -> 3 pi amplitude were determined. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:203 / 209
页数:7
相关论文
共 50 条
  • [21] Study of the process e+e- → π+π-π0 in the energy range 1.04-1.38 GeV with CMD-2 detector
    Gorbachev, DA
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2005, 20 (2-3): : 584 - 586
  • [22] A DRIFT CHAMBER FOR THE CMD-2 DETECTOR AT VEPP-2M
    AULCHENKO, VM
    KHAZIN, BI
    SOLODOV, EP
    SNOPKOV, IG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (2-3): : 299 - 303
  • [23] Superconducting rectifier fluxpump for magnet system of the CMD-2 detector
    Barkov, LM
    Bashtovoy, NS
    Karpov, SV
    Okhapkin, VS
    Ruban, AA
    Smakhtin, VP
    Snopkov, IG
    Zhuravkov, IV
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (03) : 4585 - 4590
  • [24] DRIFT CHAMBER FOR THE CMD-2 DETECTOR AT VEPP-2M.
    Aulchenko, V.M.
    Khazin, B.I.
    Solodov, E.P.
    Snopkov, I.G.
    Nuclear instruments and methods in physics research, 1986, A252 (2-3): : 299 - 303
  • [25] Precise measurement of hadronic cross sections with CMD-2 detector
    Sibidanov, AL
    HADRON SPECTROSCOPY, 2006, 814 : 478 - 485
  • [26] Measurement of ω meson parameters in π+π-π0 decay mode with CMD-2
    Akhmetshin, RR
    Anashkin, EV
    Aulchenko, VM
    Banzarov, VS
    Barkov, LM
    Baru, SE
    Bashtovoy, NS
    Bondar, AE
    Bondarev, DV
    Chernyak, DV
    Eidelman, SI
    Fedotovich, GV
    Bondarev, DV
    Chernyak, DV
    Eidelman, SI
    Fedotovich, GV
    Gabyshev, NI
    Grebeniuk, AA
    Grigoriev, DN
    Khazin, BI
    Koop, IA
    Kurdadze, LM
    Kuzmin, AS
    Logashenko, IB
    Lukin, PA
    Lysenko, AP
    Nesterenko, IN
    Okhapkin, VS
    Perevedentsev, EA
    Polunin, AA
    Purlatz, TA
    Root, NI
    Ruban, AA
    Ryskulov, NM
    Shamov, AG
    Shatunov, YM
    Shekhtman, AI
    Sher, AE
    Shwartz, BA
    Sidorov, VA
    Skrinsky, AN
    Smakhtin, VP
    Snopkov, IG
    Solodov, EP
    Stepanov, PY
    Sukhanov, AI
    Titov, VM
    Valishev, AA
    Yudin, YV
    Zverev, SG
    PHYSICS LETTERS B, 2000, 476 (1-2) : 33 - 39
  • [27] The BGO endcap calorimeter with phototriode readout for the CMD-2 detector
    Akhmetshin, RR
    Grigoriev, DN
    Kazanin, VF
    Ruban, AA
    Smakhtin, VP
    Yudin, YV
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 453 (1-2): : 249 - 254
  • [28] Study of ρ and ω meson conversion decays with the CMD-2 detector at the VEPP-2M collider
    Kazanine, V
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2005, 20 (2-3): : 606 - 608
  • [29] PERFORMANCE OF THE BGO ENDCAP CALORIMETER WITH PHOTOTRIODE READOUT FOR THE CMD-2 DETECTOR
    GRIGORIEV, DN
    AKHMETSHIN, RR
    BESCHASTNOV, PM
    FEDORENKO, VE
    PYATA, EE
    SMAKHTIN, VP
    YUDIN, YV
    SHLEGEL, VN
    VASILIEV, YV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 505 - 509
  • [30] Performance of the BGO endcap calorimeter with phototriode readout for the CMD-2 detector
    Grigoriev, D.N.
    Akhmetshin, R.R.
    Beschastnov, P.M.
    Fedorenko, V.E.
    Pyata, E.E.
    Smakhtin, V.P.
    Yudin, Yu.V.
    Shlegel, V.N.
    Vasiliev, Ya.V.
    IEEE Transactions on Nuclear Science, 1995, 42 (4 pt 1): : 505 - 509