Nanoplastics removal during drinking water treatment: Laboratory- and pilot-scale experiments and modeling

被引:44
|
作者
Pulido-Reyes, Gerardo [1 ,5 ]
Magherini, Leonardo [2 ]
Bianco, Carlo [2 ]
Sethi, Rajandrea [2 ]
von Gunten, Urs [1 ,3 ,4 ]
Kaegi, Ralf [1 ]
Mitrano, Denise M. [4 ]
机构
[1] Swiss Fed Inst Aquat Sci & Technol, Eawag, Ueberlandstr 133, CH-8600 Dubendorf, Switzerland
[2] Politecn Torino, Dept Environm Land & Infrastruct Engn DIATI, Corso Duca Abruzzi 24, I-10129 Turin, Italy
[3] Ecole Polytech Fed Lausanne, Sch Architecture Civil & Environm Engn ENAC, CH-1015 Lausanne, Switzerland
[4] Swiss Fed Inst Technol, Environm Syst Sci Dept, CH-08092 Zurich, Switzerland
[5] Spanish Natl Inst Agr & Food Res & Technol INIA C, Crta Coruna,Km 7-5, Madrid 28040, Spain
基金
瑞士国家科学基金会;
关键词
Nanoplastics; Drinking water treatment; Ozonation; Sand filtration; Granular activated carbon; SATURATED POROUS-MEDIA; NANOPARTICLE TRANSPORT; SILVER NANOPARTICLES; IONIC-STRENGTH; QUARTZ SAND; POLYSTYRENE NANOPARTICLES; SOLUTION CHEMISTRY; COLLOID TRANSPORT; RETENTION; OZONATION;
D O I
10.1016/j.jhazmat.2022.129011
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Microplastics detected in potable water sources and tap water have led to concerns about the efficacy of current drinking water treatment processes to remove these contaminants. It is hypothesized that drinking water resources contain nanoplastics (NPs), but the detection of NPs is challenging. We, therefore, used palladium (Pd)labeled NPs to investigate the behavior and removal of NPs during conventional drinking water treatment processes including ozonation, sand and activated carbon filtration. Ozone doses typically applied in drinking water treatment plants (DWTPs) hardly affect the NPs transport in the subsequent filtration systems. Amongst the different filtration media, NPs particles were most efficiently retained when aged (i.e. biofilm coated) sand was used with good agreements between laboratory and pilot scale systems. The removal of NPs through multiple filtration steps in a municipal full-scale DWTP was simulated using the MNMs software code. Removal efficiencies exceeding 3-log units were modeled for a combination of three consecutive filtration steps (rapid sand filtration, activated carbon filtration and slow sand filtration with 0.4-, 0.2- and 3.0-log-removal, respectively). According to the results from the model, the removal of NPs during slow sand filtration dominated the overall NPs removal which is also supported by the laboratory-scale and pilot-scale data. The results from this study can be used to estimate the NPs removal efficiency of typical DWTPs with similar water treatment chains.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] REMOVAL OF CYANOBACTERIAL TOXINS IN WATER-TREATMENT PROCESSES - LABORATORY AND PILOT-SCALE EXPERIMENTS
    KEIJOLA, AM
    HIMBERG, K
    ESALA, AL
    SIVONEN, K
    HIISVIRTA, L
    TOXICITY ASSESSMENT, 1988, 3 (05): : 643 - 656
  • [2] Removal of Giardia and Cryptosporidium in drinking water treatment:: a pilot-scale study
    Hsu, BM
    Yeh, HH
    WATER RESEARCH, 2003, 37 (05) : 1111 - 1117
  • [3] Oil Removal from Produced Water during Laboratory- and Pilot-Scale Gas Flotation: The Influence of Interfacial Adsorption and Induction Times
    Eftekhardadkhah, Mona
    Aanesen, Svein Viggo
    Rabe, Karsten
    Oye, Gisle
    ENERGY & FUELS, 2015, 29 (11) : 7734 - 7740
  • [4] Removal of polar organic micropollutants by pilot-scale reverse osmosis drinking water treatment
    Albergamo, Vittorio
    Blankert, Bastiaan
    Cornelissen, Emile R.
    Hofs, Bas
    Knibbe, Willem-Jan
    van der Meer, Walter
    de Voogt, Pim
    WATER RESEARCH, 2019, 148 : 535 - 545
  • [5] Biological nitrification in a full-scale and pilot-scale iron removal drinking water treatment plant
    Lytle, Darren A.
    Sorg, Thomas J.
    Wang, Lili
    Muhlen, Christy
    Rahrig, Matthew
    French, Ken
    JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2007, 56 (02): : 125 - 136
  • [6] Pilot-scale studies of hexavalent chromium removal from drinking water
    McGuire Malcolm Pirnie, 1919 Santa Monica Blvd., Santa Monica, CA 90404, United States
    不详
    不详
    不详
    Journal / American Water Works Association, 2006, 98 (02): : 134 - 143
  • [7] Pilot-scale studies of hexavalent chromium removal from drinking water
    McGuire, MJ
    Blute, NK
    Seidel, C
    Qin, G
    Fong, L
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2006, 98 (02): : 134 - 143
  • [8] Removal of chlorite from drinking water: laboratory and pilot-scale studies to predict activated carbon performance at full scale
    Sorlini, Sabrina
    Biasibetti, Michela
    Gialdini, Francesca
    Collivignarelli, Maria Cristina
    DESALINATION AND WATER TREATMENT, 2017, 64 : 165 - 172
  • [9] Fate and removal efficiency of polystyrene nanoplastics in a pilot drinking water treatment plant
    Arenas, Lina Ramirez
    Gentile, Stephan Ramseier
    Zimmermann, Stephane
    Stoll, Serge
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 813
  • [10] Effects of several water quality parameters on arsenic removal by coagulation: laboratory experiments and a pilot-scale study
    Laky, D.
    Laszlo, B.
    Licsko, I.
    WATER PRACTICE AND TECHNOLOGY, 2008, 3 (03):