Physical mechanisms of gas and perfluoron retinopexy and sub-retinal fluid displacement

被引:33
作者
Foster, WJ
Chou, T
机构
[1] Univ Calif Los Angeles, Jules Stein Eye Inst, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Biomath, Los Angeles, CA 90095 USA
关键词
D O I
10.1088/0031-9155/49/13/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Injection of gas into the eye, followed by face-down positioning, is a common protocol for the reseating of the retina in posterior and superior retinal tears and breaks. The physical mechanism by which injected gas helps reattach retinal flaps is often ascribed to the 'buoyancy' force of the injected gas bubble. The various forces at play in this system (surface tension and buoyancy) were calculated and compared. The results are extended to the case in which the retina is intact (pneumatic displacement of blood) and to the use of intraocular perfluoron (n-perfluorooctane). We show that buoyancy forces are applicable only for gas or n-perfluorooctane bubbles that are smaller than the detached retina and that do not invade underneath the retina. For larger bubbles, as is normally used in reattachment protocols, we show that it is the interfacial tension that reattaches the retina. The range of angles within which patients can position, and still maintain a gas-vitreous interface along a tear is calculated as a function of the volume of injected gas and size of the tear. The maximum retinal flap size that can be reattached using surface tension forces is also estimated.
引用
收藏
页码:2989 / 2997
页数:9
相关论文
共 11 条
[1]  
Adamson A.W., 1967, Physical chemistry of surfaces
[2]   BUOYANCY-DRIVEN MOTION OF A DEFORMABLE DROP TOWARD A PLANAR WALL AT LOW REYNOLDS-NUMBER [J].
ASCOLI, EP ;
DANDY, DS ;
LEAL, LG .
JOURNAL OF FLUID MECHANICS, 1990, 213 :287-311
[3]  
Berger JW, 1998, RETINA-J RET VIT DIS, V18, P84
[4]  
Chandrasekar S., 1981, Hydrodynamic and Hydromagnetic Stability
[5]  
DAILEY JP, 2002, COMB M RET VITR SOC
[6]   INTRAOCULAR TAMPONADE AND SURFACE-TENSION [J].
DEJUAN, E ;
MCCUEN, B ;
TIEDEMAN, J .
SURVEY OF OPHTHALMOLOGY, 1985, 30 (01) :47-51
[7]  
FOSTER WJ, 2003, 3975 ARVO
[8]  
LANDAU L. D., 1985, FLUID MECH
[9]   LOW-REYNOLDS-NUMBER MOTION OF BUBBLES, DROPS AND RIGID SPHERES THROUGH FLUID-FLUID INTERFACES [J].
MANGA, M ;
STONE, HA .
JOURNAL OF FLUID MECHANICS, 1995, 287 :279-298
[10]   Macular hole surgery without face-down positioning - A pilot study [J].
Tornambe, PE ;
Poliner, LS ;
Grote, K .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1997, 17 (03) :179-185