Evaluation of Coronary Plaques and Stents with Conventional and Photon-counting CT: Benefits of High-Resolution Photon-counting CT

被引:52
作者
Rajagopal, Jayasai R. [1 ]
Farhadi, Faraz [2 ]
Richards, Taylor [1 ]
Nikpanah, Moozhan [2 ]
Sahbaee, Pooyan [5 ]
Shanbhag, Sujata M. [3 ]
Bandettini, W. Patricia [3 ]
Saboury, Babak [2 ]
Malayeri, Ashkan A. [2 ]
Pritchard, William F. [4 ]
Jones, Elizabeth C. [2 ]
Samei, Ehsan [1 ]
Chen, Marcus Y. [3 ]
机构
[1] Duke Univ, Dept Radiol, Med Phys Grad Program, Med Ctr,Carl E Ravin Adv Imaging Labs, Durham, NC USA
[2] NHLBI, Dept Radiol & Imaging Sci, Clin Ctr, 10 Ctr Dr,Bldg 10,Room B1D417, Bethesda, MD 20892 USA
[3] NHLBI, Cardiovasc Branch, 10 Ctr Dr,Bldg 10,Room B1D417, Bethesda, MD 20892 USA
[4] NIH, Ctr Intervent Oncol Radiol & Imaging Sci, Clin Ctr, 10 Ctr Dr,Bldg 10,Room B1D417, Bethesda, MD 20892 USA
[5] Siemens Med Solut USA, Malvern, PA USA
来源
RADIOLOGY-CARDIOTHORACIC IMAGING | 2021年 / 3卷 / 05期
基金
美国国家卫生研究院;
关键词
CT-Spectral Imaging (Dual Energy); Phantom Studies; Cardiac; Physics; Technology Assessment; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY;
D O I
10.1148/ryct.2021210102
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the performance of energy-integrating detector (EID) CT, photon-counting detector CT (PCCT), and high -resolution PCCT (HR-PCCT) for the visualization of coronary plaques and reduction of stent artifacts in a phantom model. Materials and Methods: An investigational scanner with EID and PCCT subsystems was used to image a coronary artery phantom con-taining cylindrical probes simulating different plaque compositions. The phantom was imaged with and without coronary stents using both subsystems. Images were reconstructed with a clinical cardiac kernel and an additional HR-PCCT kernel. Regions of interest were drawn around probes and evaluated for in-plane diameter and a qualitative comparison by expert readers. A linear mixed-effects model was used to compare the diameter results, and a Shrout-Fleiss intraclass correlation coefficient was used to assess consistency in the reader study. Results: Comparing in-plane diameter to the physical dimension for nonstented and stented phantoms, measurements of the HR-PCCT images were more accurate (nonstented: 4.4% +/- 1.1 [standard deviation], stented: -9.4% +/- 4.6) than EID (nonstented: 15.5% +/- 4.0, stented: -19.5% +/- 5.8) and PCCT (nonstented: 19.4% +/- 2.5, stented: -18.3% +/- 4.4). Our analysis of variance found diameter measurements to be different across image groups for both nonstented and stented cases (P < .001). HR-PCCT showed less change on average in percent stenosis due to the addition of a stent (-5.5%) than either EID (+90.5%) or PCCT (+313%). For both nonstented and stented phantoms, observers rated the HR-PCCT images as having higher plaque conspicuity and as being the image type that was least impacted by stent artifacts, with a high level of agreement (interclass correlation coefficient = 0.85). Conclusion: Despite increased noise, HR-PCCT images were able to better visualize coronary plaques and reduce stent artifacts com-pared with EID or PCCT reconstructions. (C) RSNA, 2021
引用
收藏
页数:8
相关论文
共 23 条
[11]   Coronary CT angiography and high-risk plaque morphology [J].
Motoyama S. ;
Sarai M. ;
Narula J. ;
Ozaki Y. .
Cardiovascular Intervention and Therapeutics, 2013, 28 (1) :1-8
[12]   Computed Tomographic Angiography Characteristics of Atherosclerotic Plaques Subsequently Resulting in Acute Coronary Syndrome [J].
Motoyama, Sadako ;
Sarai, Masayoshi ;
Harigaya, Hiroto ;
Anno, Hirofumi ;
Inoue, Kaori ;
Hara, Tomonori ;
Naruse, Hiroyuki ;
Ishii, Junichi ;
Hishida, Hitoshi ;
Wong, Nathan D. ;
Virmani, Renu ;
Kondo, Takeshi ;
Ozaki, Yukio ;
Narula, Jagat .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (01) :49-57
[13]  
Nikolaou K, 2011, INSIGHTS IMAGING, V2, P9, DOI 10.1007/s13244-010-0049-0
[14]   Variability of stenosis characterization: Impact of coronary vessel motion in cardiac CT [J].
Richards, Taylor ;
Segars, Paul ;
Samei, Ehsan .
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
[15]   Quantification of uncertainty in the assessment of coronary plaque in CCTA through a dynamic cardiac phantom and 3D-printed plaque model [J].
Richards, Taylor ;
Sturgeon, Gregory M. ;
Ramirez-Giraldo, Juan Carlos ;
Rubin, Geoffrey D. ;
Koweek, Lynne Hurwitz ;
Segars, William Paul ;
Samei, Ehsan .
JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)
[16]   INTRACLASS CORRELATIONS - USES IN ASSESSING RATER RELIABILITY [J].
SHROUT, PE ;
FLEISS, JL .
PSYCHOLOGICAL BULLETIN, 1979, 86 (02) :420-428
[17]   Feasibility of improving vascular imaging in the presence of metallic stents using spectral photon counting CT and K-edge imaging [J].
Sigovan, Monica ;
Si-Mohamed, Salim ;
Bar-Ness, Daniel ;
Mitchell, Julia ;
Langlois, Jean-Baptiste ;
Coulon, Philippe ;
Roessl, Ewald ;
Blevis, Ira ;
Rokni, Michal ;
Rioufol, Gilles ;
Douek, Philippe ;
Boussel, Loic .
SCIENTIFIC REPORTS, 2019, 9 (1)
[18]   Quarter-millimeter spectral coronary stent imaging with photon-counting CT: Initial experience [J].
Symons, Rolf ;
De Bruecker, Yves ;
Roosen, John ;
Van Camp, Laurent ;
Cork, Tyler E. ;
Kappler, Steffen ;
Ulzheimer, Stefan ;
Sandfort, Veit ;
Bluemke, David A. ;
Pourmorteza, Amir .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2018, 12 (06) :509-515
[19]   Photon Counting Computed Tomography With Dedicated Sharp Convolution Kernels Tapping the Potential of a New Technology for Stent Imaging [J].
von Spiczak, Jochen ;
Mannil, Manoj ;
Peters, Benjamin ;
Hickethier, Tilman ;
Baer, Matthias ;
Henning, Andre ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Manka, Robert ;
Maintz, David ;
Alkadhi, Hatem .
INVESTIGATIVE RADIOLOGY, 2018, 53 (08) :486-494
[20]   Photon-counting CT: Technical Principles and Clinical Prospects [J].
Willemink, Martin J. ;
Persson, Mats ;
Pourmorteza, Amir ;
Pelc, Norbert. ;
Fleischmann, Dominik .
RADIOLOGY, 2018, 289 (02) :293-312