Experimental investigation on thermal and mechanical behaviour of composite floors exposed to standard fire

被引:45
作者
Li, Guo-Qiang [1 ,3 ]
Zhang, Nasi [2 ]
Jiang, Jian [3 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
[2] Genex Syst, Newport News, VA 23606 USA
[3] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Fire resistance; Experimental investigation; Composite floor; Unprotected secondary beam; Direction of rib; Location of reinforcement; EC4; DIFFERENT HEATING REGIMES; STRUCTURAL BEHAVIOR; MEMBRANE ACTION; CONCRETE SLABS; COMPARTMENT;
D O I
10.1016/j.firesaf.2017.02.009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents experimental investigations on the thermal and mechanical behavior of composite floors subjected to ISO standard fire. Four 5.2 mx3.7 m composite slabs are tested with different combinations of the presence of one unprotected secondary beam, direction of ribs, and location of the reinforcement. The experimental results show that the highest temperature in the reinforcements occurs during the cooling phase (30-50 degrees C increment after 10-min cooling). The temperature at the unexposed side of the slabs is below 100 degrees C up to 100-min heating, compared to the predicted fire resistance close to 90 mins from EC4. For the slabs without secondary beams, the cracks first occur around the boundaries of the slab, while for the slabs supported by one unprotected secondary beam, concrete cracks first occur on the top of the slab above the beam due to the negative bending moment, and later on develop around boundaries. Debonding is observed between the steel deck and concrete slab. The secondary beam significantly impacts the deformation shape of tested slabs. Although a large deflection, 1/20 of the span length, is reached in the tests, the composite slabs can still provide sufficient load-bearing capacity due to membrane action. The occurrence of tensile membrane action is confirmed by the measured tensile stress in the reinforcement and compressive stress in the concrete. A comparison between measured and predicted fire resistance of the slabs indicates that EC4 calculations might be used for the composite slabs beyond the specified geometry limit, and the prediction is conservative.
引用
收藏
页码:63 / 76
页数:14
相关论文
共 37 条
  • [11] Nonlinear behaviour of unprotected composite slim floor steel beams exposed to different fire conditions
    Ellobody, Ehab
    THIN-WALLED STRUCTURES, 2011, 49 (06) : 762 - 771
  • [12] Experimental study of performance of engineered bamboo beams exposed to three-sided standard fire
    Chen, Lingzhu
    Xu, Qingfeng
    Leng, Yubing
    Harries, Kent A.
    Wang, Zhuolin
    FIRE SAFETY JOURNAL, 2019, 106 : 52 - 60
  • [13] Experimental study for behabior of the mullions of stick system aluminum curtain walls exposed to standard fire
    Eguchi J.
    Ikeda K.
    Chiba F.
    Ohmiya Y.
    Sugahara S.
    2017, Architectural Institute of Japan (82): : 1287 - 1297
  • [14] Experimental and numerical investigation of concrete-filled stainless steel columns exposed to fire
    Tao, Zhong
    Ghannam, Mohamed
    Song, Tian-Yi
    Han, Lin-Hai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 118 : 120 - 134
  • [15] Experimental study on the fire resistance of all-composite and hybrid web-core sandwich panels for building floors
    Proenca, M.
    Garrido, M.
    Correia, J. R.
    Sena-Cruz, J.
    COMPOSITE STRUCTURES, 2024, 337
  • [16] Experimental investigation of individual embossed mechanical bond in composite floor
    Seres, Noemi
    Dunai, Laszlo
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 357 - 362
  • [17] Thermal Behaviour of Rebars and Steel Deck Components of Composite Slabs under Natural Fire
    Filho, Marcilio M. A.
    Piloto, Paulo A. G.
    Balsa, Carlos
    JOURNAL OF COMPOSITES SCIENCE, 2022, 6 (08):
  • [18] Experimental and analytical investigation on fire resistance of glulam-concrete composite beams
    Du, Hao
    Hu, Xiamin
    Xie, Zhong
    Meng, Yanfei
    JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [19] Thermal and mechanical transient behaviour of steel doors installed in non-load-bearing partition wall assemblies during exposure to the standard fire test
    Nassif, Ayman Y.
    Yoshitake, Isamu
    Vimonsatit, Vanissorn
    FIRE AND MATERIALS, 2016, 40 (08) : 1070 - 1089
  • [20] Thermal and structural behaviour of a full-scale composite building subject to a severe compartment fire
    Foster, Samantha
    Chladna, Magdalena
    Hsieh, Christina
    Burgess, Ian
    Plank, Roger
    FIRE SAFETY JOURNAL, 2007, 42 (03) : 183 - 199