Early Canadian Multicenter Experience With WATCHMAN for Percutaneous Left Atrial Appendage Closure

被引:23
|
作者
Saw, Jacqueline [1 ]
Fahmy, Peter [1 ]
Azzalini, Lorenzo [2 ]
Marquis, Jean-Francois [3 ]
Hibbert, Benjamin [3 ]
Morillo, Carlos [4 ]
Carrizo, Aldo [4 ]
Ibrahim, Reda [2 ]
机构
[1] Univ British Columbia, Vancouver Gen Hosp, Div Cardiol, 2775 Laurel St,Level 9, Vancouver, BC V5Z 1M9, Canada
[2] Montreal Heart Inst, Div Cardiol, Montreal, PQ, Canada
[3] Ottawa Heart Inst, Div Cardiol, Ottawa, ON, Canada
[4] Hamilton Gen Hosp, Div Cardiol, Hamilton, ON, Canada
基金
加拿大健康研究院;
关键词
clinical: implantable devices--atrial fibrillation; left atrial appendage closure; ORAL ANTICOAGULATION; FIBRILLATION; DEVICE; PREVENTION; STROKE; GUIDELINES;
D O I
10.1111/jce.13168
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Percutaneous Left Atrial Appendage Closure BackgroundThere are limited data with WATCHMAN (Boston Scientific Corporation, Natick, MA, USA) for left atrial appendage (LAA) closure in patients with nonvalvular atrial fibrillation (AF) and contraindications to anticoagulation. The purpose of this study was to evaluate the safety and efficacy of WATCHMAN in our early Canadian experience. MethodsWe report our pooled consecutive series of patients who underwent WATCHMAN implantation at four major Canadian centers. Indications for LAA closure were CHADS(2) 1 or CHA(2)DS(2)-VASc 2, and contraindication/intolerance to or failure on anticoagulation. Follow-up imaging was typically performed 1-6 months postprocedure. ResultsOne hundred and six patients underwent LAA closure with WATCHMAN from May 2013 to October 2015. The mean age was 74.8 7.7, mean CHADS(2) score was 2.8 +/- 1.2, CHA(2)DS(2)-VASc score was 4.3 +/- 1.5, and HASBLED score was 3.2 +/- 1.2. Permanent AF was present in 67.9% and paroxysmal AF in 32.1%. Indications for LAA closure were prior bleeding 89.6% (87 major bleeding and 8 minor bleeding), 9.4% were deemed high risk for bleeding, and 0.9% with recurrent strokes on warfarin. Procedural success was 97.2% (103 of 106), with one device embolization (snared percutaneously), one implant failure due to inadequate LAA depth, and one cardiac perforation requiring surgical repair before WATCHMAN implantation. The composite major safety event-rate was 1.9% (1 death and 1 device embolization). Mean hospital stay was 1.8 +/- 4.7 days. Antithrombotic therapy postimplant included dual antiplatelet therapy in 76 of 103 (73.8%). Mean follow-up was 210 +/- 182 days; there were two transient ischemic attacks, with estimated 66% reduction in thromboembolic events relative to CHADS(2) predicted risk. ConclusionIn our early Canadian experience, WATCHMAN for LAA closure in patients contraindicated to anticoagulation appeared safe and effective.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 50 条
  • [11] Antithrombotic Regimen After Percutaneous Left Atrial Appendage Closure
    Ryuzaki, Satoko
    Kondo, Yusuke
    Nakano, Miyo
    Nakano, Masahiro
    Kajiyama, Takatsugu
    Ito, Ryo
    Kitagawa, Mari
    Sugawara, Masafumi
    Chiba, Toshinori
    Yoshino, Yutaka
    Kobayashi, Yoshio
    CIRCULATION JOURNAL, 2023, 87 (12) : 1820 - +
  • [12] Left Atrial Appendage Closure
    Lin, Albert C.
    Knight, Bradley P.
    PROGRESS IN CARDIOVASCULAR DISEASES, 2015, 58 (02) : 195 - 201
  • [13] EWOLUTION of WATCHMAN Left Atrial Appendage Closure to Patients With Contraindication to Oral Anticoagulation
    Turagam, Mohit K.
    Reddy, Vivek Y.
    Dukkipati, Srinivas R.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (04)
  • [14] Left atrial appendage perforation during appendage angiography treated by percutaneous left atrial appendage closure: a case report
    Champagne, Catherine
    Dognin, Nicolas
    Rodes-Cabau, Josep
    Champagne, Jean
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2021, 5 (05)
  • [15] Imaging for percutaneous left atrial appendage closure
    Prakash, Roshan
    Saw, Jacqueline
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (02) : 437 - 450
  • [16] Left Atrial Appendage Closure - The WATCHMAN Device
    Akinapelli, Abhilash
    Bansal, Ojas
    Chen, Jack P.
    Pflugfelder, Alex
    Gordon, Nicole
    Stein, Kenneth
    Huibregtse, Barbara
    Hou, Dongming
    CURRENT CARDIOLOGY REVIEWS, 2015, 11 (04) : 334 - 340
  • [17] Transcatheter closure of the left atrial appendage: initial experience with the WATCHMAN device
    Ding, Jiandong
    Zhu, Jian
    Lu, Jing
    Ding, Xiuxia
    Zhang, Xiaoli
    Lu, Wenbin
    Ao, Mingqiang
    Ma, Genshan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (09): : 15230 - 15237
  • [18] Atrial and Brain Natriuretic Peptide Secretion After Percutaneous Closure of the Left Atrial Appendage With the Watchman Device
    Majunke, Nicolas
    Sandri, Marcus
    Adams, Volker
    Daehnert, Ingo
    Mangner, Norman
    Schuler, Gerhard
    Moebius-Winkler, Sven
    JOURNAL OF INVASIVE CARDIOLOGY, 2015, 27 (10) : 448 - 452
  • [19] Frailty in patients undergoing percutaneous left atrial appendage closure
    Wang, Allen
    Ferro, Enrico G.
    Song, Yang
    Xu, Jiaman
    Sun, Tianyu
    Yeh, Robert W.
    Strom, Jordan B.
    Kramer, Daniel B.
    HEART RHYTHM, 2022, 19 (05) : 814 - 821
  • [20] Left Atrial Appendage Closure With the Watchman Device in Patients With a Contraindication for Oral Anticoagulation The ASAP Study (ASA Plavix Feasibility Study With Watchman Left Atrial Appendage Closure Technology)
    Reddy, Vivek Y.
    Moebius-Winkler, Sven
    Miller, Marc A.
    Neuzil, Petr
    Schuler, Gerhard
    Wiebe, Jens
    Sick, Peter
    Sievert, Horst
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (25) : 2551 - 2556