Post-Biopsy Manoeuvres to Reduce Pneumothorax Incidence in CT-Guided Transthoracic Lung Biopsies: A Systematic Review and Meta-analysis

被引:43
作者
Huo, Ya Ruth [1 ]
Chan, Michael Vinchill [2 ,3 ]
Habib, Al-Rahim [3 ]
Lui, Isaac [2 ]
Ridley, Lloyd [2 ,3 ]
机构
[1] Bankstown Campbelltown Hosp, NSW Hlth, Sydney, NSW, Australia
[2] Concord Repatriat Gen Hosp, Dept Radiol, Sydney, NSW, Australia
[3] Univ Sydney, Fac Med, Sydney, NSW, Australia
关键词
Pneumothorax; Lung biopsy; CT-guided lung biopsy; Normal saline tract; Tract plug; Blood patch; Rollover; Breath-hold; Systematic review; Meta-analysis; BLOOD PATCH TECHNIQUE; CHEST TUBE PLACEMENT; NEEDLE TRACK; POSITION; RATES; PLUG;
D O I
10.1007/s00270-019-02196-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This systematic review and meta-analysis investigated post-biopsy manoeuvres to reduce pneumothorax following computed tomography-guided percutaneous transthoracic lung biopsy. Twenty-one articles were included with 7080 patients. Chest drain insertion rates were significantly reduced by ninefold with the normal saline tract sealant compared to controls (OR 0.11, 95% CI 0.02-0.48), threefold with the rapid rollover manoeuvre to puncture site down (OR 0.34, 95% CI 0.18-0.63), threefold with the tract plug (OR 0.33, 95% CI 0.22-0.48) and threefold with the blood patch (OR 0.39, 95% CI 0.26-0.58). The absolute chest drain insertion rates were the lowest in the normal saline tract sealant (0.8% vs 7.3% for controls), rapid rollover (1.9% vs 5.2%), deep expiration and breath-hold on needle extraction (0.9% vs 1.8%) and standard rollover versus no rollover (2.6% vs 5.2%). These findings highlight post-biopsy manoeuvres which could help reduce pneumothorax and chest drain insertions following lung biopsies.
引用
收藏
页码:1062 / 1072
页数:11
相关论文
共 50 条
  • [21] Reduced Incidence of Pneumothorax and Chest Tube Placement following Transthoracic CT-Guided Lung Biopsy with Gelatin Sponge Torpedo Track Embolization: A Propensity Score-Matched Study
    Feinggumloon, Sasikorn
    Radchauppanone, Panupong
    Panpikoon, Tanapong
    Buangam, Chinnarat
    Pichitpichatkul, Kaewpitcha
    Treesit, Tharintorn
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (16)
  • [22] The nodule-pleura relationship affects pneumothorax in CT-guided percutaneous transthoracic needle biopsy: avoiding to cross pleural tail sign may reduce the incidence of pneumothorax
    Deng, Xu-Bo
    Xie, Lei
    Zhu, Hai-Bin
    Liu, Yu-Liang
    Yang, Shou-Xin
    Zhao, Bo
    Sun, Rui-Jia
    Li, Xiao-Ting
    Chen, Mai-Lin
    Sun, Ying-Shi
    BMC PULMONARY MEDICINE, 2024, 24 (01):
  • [23] Subpleural injection of gelatin sponge particles to reduce pneumothorax incidence in CT-guided lung biopsies: a retrospective single-center case-control study
    Zhu, Zi-Yi
    Yun, Ya-Qin
    Li, Hao
    Qin, Zhong-Qiang
    Qian, Zhen
    Zhu, Yun
    Li, Shu-Hua
    Xie, Bo
    Yuan, Mu
    BMC CANCER, 2025, 25 (01)
  • [24] Curved Needles in CT-Guided Fine Needle Biopsies of Pulmonary Lesions: an Ability to Reduce the Incidence of Pneumothorax
    De Filippo, Massimo
    Milanese, Gianluca
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (10) : 1525 - 1527
  • [25] Curved Needles in CT-Guided Fine Needle Biopsies of Pulmonary Lesions: an Ability to Reduce the Incidence of Pneumothorax
    Massimo De Filippo
    Gianluca Milanese
    CardioVascular and Interventional Radiology, 2016, 39 : 1525 - 1527
  • [26] Ultrasound versus computed tomography-guided transthoracic biopsy for pleural and peripheral lung lesions: a systematic review and meta-analysis
    Li, Xuemei
    Kong, Lan
    ACTA RADIOLOGICA, 2023, 64 (12) : 2999 - 3008
  • [27] Pneumothorax and pulmonary hemorrhage after CT-guided lung biopsy: incidence, clinical significance and correlation
    Sabatino, Vittorio
    Russo, Umberto
    D'Amuri, Fabiano
    Bevilacqua, Andrea
    Pagnini, Francesco
    Milanese, Gianluca
    Gentili, Francesco
    Nizzoli, Rita
    Tiseo, Marcello
    Pedrazzi, Giuseppe
    De Filippo, Massimo
    RADIOLOGIA MEDICA, 2021, 126 (01): : 170 - 177
  • [28] Pneumothorax and pulmonary hemorrhage after CT-guided lung biopsy: incidence, clinical significance and correlation
    Vittorio Sabatino
    Umberto Russo
    Fabiano D’Amuri
    Andrea Bevilacqua
    Francesco Pagnini
    Gianluca Milanese
    Francesco Gentili
    Rita Nizzoli
    Marcello Tiseo
    Giuseppe Pedrazzi
    Massimo De Filippo
    La radiologia medica, 2021, 126 : 170 - 177
  • [29] CT-Guided Cutting Needle Lung Biopsy Using "Liquid Withdraw" Technique: Prominently Reduced Incidence of Pneumothorax
    Li, Rutian
    Ren, Wei
    Zhang, Hang
    Wang, Lifeng
    Liu, Baorui
    JOURNAL OF THORACIC ONCOLOGY, 2015, 10 (09) : S397 - S397
  • [30] Diagnostic outcome and safety of CT-guided core needle biopsy for mediastinal masses: a systematic review and meta-analysis
    Han Na Lee
    Seong Jong Yun
    Jung Im Kim
    Chang-Woo Ryu
    European Radiology, 2020, 30 : 588 - 599