Comparison of Loop-Mediated Isothermal Amplification, Microscopy, Culture, and PCR for Diagnosis of Pulmonary Tuberculosis

被引:8
|
作者
Phetsuksiri, Benjawan [1 ]
Rudeeaneksin, Janisara [1 ]
Srisungngam, Sopa [1 ]
Bunchoo, Supranee [1 ]
Klayut, Wiphat [1 ]
Nakajima, Chie [2 ,3 ]
Hamada, Shigeyuki [4 ,5 ]
Suzuki, Yasuhiko [2 ,3 ]
机构
[1] Minist Publ Hlth, Dept Med Sci, Natl Inst Hlth, Nonthaburi, Thailand
[2] Hokkaido Univ, Div Bioresources, Res Ctr Zoonosis Control, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Global Inst Collaborat Res & Educ GI CoRE, Global Stn Zoonosis Control, Sapporo, Hokkaido, Japan
[4] Res Collaborat Ctr Emerging & Re Emerging Infect, Sect Bacterial Infect, Nonthaburi, Thailand
[5] Osaka Univ, Res Inst Microbial Dis, Osaka, Japan
关键词
MYCOBACTERIUM-TUBERCULOSIS; RAPID IDENTIFICATION; LAMP ASSAY; COMPLEX;
D O I
10.7883/yoken.JJID.2019.335
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The diagnosis of tuberculosis (TB) in endemic countries is challenging due to high caseloads and limited resources. A simple and cost-effective diagnostic test for the rapid detection of Mycobacterium tuberculosis (M tuberculosis) in clinical specimens is crucially needed. We evaluated the performance of an in-house assay based on loop-mediated isothermal amplification (LAMP) targeting the M tuberculosis 16S ribosomal RNA (rRNA) gene for the diagnosis of TB in Thailand. A total of 252 sputum samples from suspected cases of pulmonary TB were analyzed. The sensitivity of LAMP was 99.04% (103/104; 95% confidence interval [CI]: 94.76-9.98%) and 72.73% (16/22; 95% CI: 49.78-89.27%) for smear-positive and smear-negative samples with TB-culture positivity, respectively. LAMP detected 20.69% (24/116) of TB culture negative samples but all those were positive by conventional polymerase chain reaction (PCR). The sensitivity of LAMP was higher than that of sputum microscopy while the performance of LAMP was similar to PCR. None of the samples positive for non-tuberculous mycobacteria by culture and PCR were positive by LAMP. Compared to TB culture, the positive predictive value (PPV), negative predictive value (NPV), and kappa coefficient of LAMP were 83.22%, 88.33%, and 0.75 respectively. Based on the diagnostic performance, we propose that LAMP would be suitable as a potential diagnostic test for rapid TB diagnosis in resource-limited laboratory settings.
引用
收藏
页码:272 / 277
页数:6
相关论文
共 50 条
  • [1] A loop-mediated isothermal amplification assay for the diagnosis of pulmonary tuberculosis
    Sharma, G.
    Tewari, R.
    Dhatwalia, S. K.
    Yadav, R.
    Behera, D.
    Sethi, S.
    LETTERS IN APPLIED MICROBIOLOGY, 2019, 68 (03) : 219 - 225
  • [2] Comparison of the Efficacies of Loop-Mediated Isothermal Amplification, Fluorescence Smear Microscopy and Culture for the Diagnosis of Tuberculosis
    George, Geojith
    Mony, Prem
    Kenneth, John
    PLOS ONE, 2011, 6 (06):
  • [3] Loop-mediated isothermal amplification as alternative to PCR for the diagnosis of extra-pulmonary tuberculosis
    Joon, D.
    Nimesh, M.
    Saluja, D.
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2015, 19 (08) : 986 - 991
  • [4] Comparison of loop-mediated isothermal amplification and real-time PCR for the diagnosis of tuberculous pleurisy
    Yang, B.
    Wang, X.
    Li, H.
    Li, G.
    Cao, Z.
    Cheng, X.
    LETTERS IN APPLIED MICROBIOLOGY, 2011, 53 (05) : 525 - 531
  • [5] Loop-mediated isothermal amplification assay for rapid and sensitive diagnosis of tuberculosis
    Kumar, Parveen
    Pandya, Deepal
    Singh, Niti
    Behera, Digambar
    Aggarwal, Praveen
    Singh, Sarman
    JOURNAL OF INFECTION, 2014, 69 (06) : 607 - 615
  • [6] LOOP MEDIATED ISOTHERMAL AMPLIFICATION FOR THE RAPID DIAGNOSIS OF PULMONARY TUBERCULOSIS
    Krishna, Ganga Raju
    Valsan, Chithra
    Sathiavathy, K. A.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (29): : 2328 - 2331
  • [7] Comparison of Nested-PCR and Loop-Mediated Isothermal Amplification for Cutaneous Leishmaniasis Diagnosis
    Saki, Jasem
    Amraee, Davod
    Ghasemian, Mehrdad
    JUNDISHAPUR JOURNAL OF MICROBIOLOGY, 2019, 12 (08)
  • [8] Pragmatic accuracy of an in-house loop-mediated isothermal amplification (LAMP) for diagnosis of pulmonary tuberculosis in a Thai community hospital
    Toonkomdang, Sarawut
    Phinyo, Phichayut
    Phetsuksiri, Benjawan
    Patumanond, Jayanton
    Rudeeaneksin, Janisara
    Klayut, Wiphat
    Lin, Baochuan
    PLOS ONE, 2020, 15 (07):
  • [9] Real-time fluorescence Loop-Mediated Isothermal Amplification (LAMP) for rapid and reliable diagnosis of pulmonary tuberculosis
    Cao, Donglin
    Hu, Liangshan
    Lin, Maorui
    Li, Mingyou
    Ye, Zebing
    Sun, Hongtao
    Huang, Jiwei
    Yang, Huawen
    Tian, Junzhang
    JOURNAL OF MICROBIOLOGICAL METHODS, 2015, 109 : 74 - 78
  • [10] Diagnosis of osteoarticular tuberculosis: multi-targeted loop-mediated isothermal amplification assay versus multiplex-PCR
    Khan, Anish
    Kamra, Ekta
    Singh, Raj
    Sharma, Vikrant
    Singh, Vishwajeet
    Mori, Preeti
    Kaushik, Samander
    Yadays, Aparna
    Mehta, Promod K.
    FUTURE MICROBIOLOGY, 2021, 16 (13) : 935 - 948