Eyewitness to history: Landmarks in the development of computerized electrocardiography

被引:20
作者
Rautaharju, Pentti M. [1 ]
机构
[1] Wake Forest Sch Med, Div Publ Hlth Sci, Winston Salem, NC 27157 USA
关键词
ECG history; Computer ECG; ECG readers; Classification accuracy; DIAGNOSTIC PERFORMANCE; PROGRAM; ECG; SYSTEM; QT;
D O I
10.1016/j.jelectrocard.2015.11.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of digital computers for ECG processing was pioneered in the early 1960s by two immigrants to the US, Hubert Pipberger, who initiated a collaborative VA project to collect an ECG-independent Frank lead data base, and Cesar Caceres at NIH who selected for his ECAN program standard 12-lead ECGs processed as single leads. Ray Bonner in the early 1970s placed his IBM 5880 program in a cart to print ECGs with interpretation, and computer-ECG programs were developed by Telemed, Marquette, HP-Philips and Mortara. The "Common Standards for quantitative Electrocardiography (CSE)" directed by Jos Willems evaluated nine ECG programs and eight cardiologists in clinically-defined categories. The total accuracy by a representative "average" cardiologist (75.5%) was 5.8% higher than that of the average program (69.7, p < 0.001). Future comparisons of computer-based and expert reader performance are likely to show evolving results with continuing improvement of computer-ECG algorithms and changing expertise of ECG interpreters. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 31 条
[1]   COMPARATIVE DIAGNOSTIC PERFORMANCE OF THE TELEMED COMPUTER ECG PROGRAM [J].
BERNARD, P ;
CHAITMAN, BR ;
SCHOLL, JM ;
VAL, PG ;
CHABOT, M .
JOURNAL OF ELECTROCARDIOLOGY, 1983, 16 (01) :97-103
[2]   THE ELECTROCARDIOGRAM IN POPULATION STUDIES - A CLASSIFICATION SYSTEM [J].
BLACKBURN, H ;
KEYS, A ;
SIMONSON, E ;
RAUTAHARJU, P ;
PUNSAR, S .
CIRCULATION, 1960, 21 (06) :1160-1175
[3]   NEW COMPUTER-PROGRAM FOR ANALYSIS OF SCALAR ELECTROCARDIOGRAMS [J].
BONNER, RE ;
CREVASSE, L ;
FERRER, MI ;
GREENFIELD, JC .
COMPUTERS AND BIOMEDICAL RESEARCH, 1972, 5 (06) :629-653
[4]   COMPUTER EXTRACTION OF ELECTROCARDIOGRAPHIC PARAMETERS [J].
CACERES, CA ;
TOLLES, WE ;
RIKLI, AE ;
CARBERY, WJ ;
MCBRIDE, JM ;
ABRAHAM, S ;
STEINBERG, CA .
CIRCULATION, 1962, 25 (02) :356-&
[5]  
Caceres CA, DIAGNOSTIC COMPUTERS, P19691
[6]  
Caceres Cesar A, 1970, CLIN ELECTROCARDIOGR
[7]   NORMAL ECG STANDARDS FOR INFANTS AND CHILDREN [J].
DAVIGNON, A ;
RAUTAHARJU, P ;
BOISSELLE, E ;
SOUMIS, F ;
MEGELAS, M ;
CHOQUETTE, A .
PEDIATRIC CARDIOLOGY, 1980, 1 (02) :123-131
[8]  
Drazen E, 1988, J ELECTROCARDIOL S, V21, pS104
[9]   AN ACCURATE, CLINICALLY PRACTICAL SYSTEM FOR SPATIAL VECTORCARDIOGRAPHY [J].
FRANK, E .
CIRCULATION, 1956, 13 (05) :737-749
[10]   QUEST FOR OPTIMAL ELECTROCARDIOGRAPHY [J].
HORAN, LG .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (01) :126-129