Chiral recognition of amino acid enantiomers using high-definition differential ion mobility mass spectrometry

被引:43
作者
Zhang, J. Diana [1 ]
Kabir, K. M. Mohibul [1 ]
Lee, Hyun Eui [1 ]
Donald, William A. [1 ]
机构
[1] Univ New South Wales, Sch Chem, Sydney, NSW 2052, Australia
基金
澳大利亚研究理事会;
关键词
Chiral recognition; Enantiomer separation; Differential ion mobility; High-field asymmetric waveform ion mobility; Ion mobility spectrometry; Mass spectrometry; LIQUID-CHROMATOGRAPHY; GAS; SEPARATIONS; COMPLEXATION; IDENTIFICATION; BIOMOLECULES; PERFORMANCE; ISOMERS; PLASMA;
D O I
10.1016/j.ijms.2018.02.003
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Enantiomeric analysis of small molecules is important in many research fields, including in drug development. Here, chiral recognition of amino acid enantiomers using differential ion mobility spectrometry (DMS) mass spectrometry (MS) is demonstrated. Diastereomeric proton bound complexes were formed between enantiomers of amino acids (tryptophan and phenylalanine) and N-tert-butoxycarbonyl-O-benzyl-t-serine (BBS) by electrospray ionization for analysis by DMS-MS and collision-induced dissociation (CID). If the DMS resolution is sufficiently high, ionic diastereomers (as opposed to enantiomers) can in principle be separated without the use of a chiral gas. Peaks corresponding to the Land D-enantiomers for both tryptophan and phenylalanine in the DMS-MS spectra were resolved by increasing the ratio of He in the carrier gas from 100% N-2 to 50:50 He:N-2 %. In contrast, CID spectra of the corresponding diastereomeric dimer complex ions were nearly identical, indicating that chiral recognition by CID was not possible under these conditions. For mixtures of L- and D-tryptophan, a linear calibration curve can be obtained by plotting the enantiomeric excess measured by DMS-MS vs. the known values in solution (slope of 1.000, intercept of -0.010 and R-2 of 0.997). That is, enantiopurity can be quantified using a separation process that occurs in milliseconds. Thus, DMS-MS analysis of proton bound diastereomeric dimers is a powerful approach for the rapid enantiomeric analysis of relatively small molecules. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 46 条
[1]  
A Shvartsburg Alexandre, 2013, Mass Spectrom (Tokyo), V2, pS0011, DOI 10.5702/massspectrometry.S0011
[2]  
Abian J, 1999, J MASS SPECTROM, V34, P157, DOI 10.1002/(SICI)1096-9888(199903)34:3<157::AID-JMS804>3.3.CO
[3]  
2-W
[4]  
Aboul Enein H. Y, 1997, IMPACT STEREOCHEMIST
[5]  
[Anonymous], 1992, Chirality, V4, P338
[6]   ENANTIOSELECTIVITY OF MASS SPECTROMETRY: CHALLENGES AND PROMISES [J].
Awad, Hanan ;
El-Aneed, Anas .
MASS SPECTROMETRY REVIEWS, 2013, 32 (06) :466-483
[7]   Combining density functional theory (DFT) and collision cross-section (CCS) calculations to analyze the gas-phase behaviour of small molecules and their protonation site isomers [J].
Boschmans, Jasper ;
Jacobs, Sam ;
Williams, Jonathan P. ;
Palmer, Martin ;
Richardson, Keith ;
Giles, Kevin ;
Lapthorn, Cris ;
Herrebout, Wouter A. ;
Lemiere, Filip ;
Sobott, Frank .
ANALYST, 2016, 141 (13) :4044-4054
[8]  
Both P, 2014, NAT CHEM, V6, P65, DOI [10.1038/nchem.1817, 10.1038/NCHEM.1817]
[9]   Review on Ion Mobility Spectrometry. Part 2: hyphenated methods and effects of experimental parameters [J].
Cumeras, R. ;
Figueras, E. ;
Davis, C. E. ;
Baumbach, J. I. ;
Gracia, I. .
ANALYST, 2015, 140 (05) :1391-1410
[10]   CHIRAL DRUGS - THE FDA PERSPECTIVE ON MANUFACTURING AND CONTROL [J].
DECAMP, WH .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (11-12) :1167-1172