Noninvasive volumetric Imaging and morphometry of the rodent retina with high-speed, ultrahigh-resolution optical coherence tomography

被引:132
作者
Srinivasan, Vivek J.
Ko, Tony H.
Wojtkowski, Maciej
Carvalho, Mariana
Clermont, Allen
Bursell, Sven-Erik
Song, Qin Hui
Lem, Janis
Duker, Jay S.
Schuman, Joel S.
Fujimoto, James G.
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[3] Tufts Univ, New England Eye Ctr, Mol Cardiol Res Inst, Boston, MA 02111 USA
[4] Tufts Univ, New England Eye Ctr, Ctr Vis Res, Boston, MA 02111 USA
[5] Harvard Univ, Sch Med, Joslin Diabet Ctr, Div Res, Boston, MA 02115 USA
[6] Harvard Univ, Sch Med, Joslin Diabet Ctr, Beetham Eye Inst, Boston, MA 02115 USA
[7] Univ Pittsburgh, Sch Med, Ctr Eye, Dept Ophthalmol, Pittsburgh, PA 15260 USA
关键词
D O I
10.1167/iovs.06-0195
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To demonstrate high-speed, ultrahigh-resolution optical coherence tomography (OCT) for noninvasive, in vivo, three-dimensional imaging of the retina in rat and mouse models. METHODS. A high-speed, ultrahigh-resolution OCT system using spectral, or Fourier domain, detection has been developed for small animal retinal imaging. Imaging is performed with a contact lens and postobjective scanning. An axial image resolution of 2.8 mu m is achieved with a spectrally broadband superluminescent diode light source with a bandwidth of similar to 150 nm at similar to 900-nm center wavelength. Imaging can be performed at 24,000 axial scans per second, which is similar to 100 times faster than previous ultrahigh-resolution OCT systems. High-definition and three-dimensional retinal imaging is performed in vivo in mouse and rat models. RESULTS. High-speed, ultrahigh-resolution OCT enabled high-definition, high transverse pixel density imaging of the murine retina and visualization of all major intraretinal layers. Raster scan protocols enabled three-dimensional volumetric imagingand comprehensive retinal segmentation algorithms allowed measurement of retinal layers. An OCT fundus image, akin to a fundus photograph was generated by axial summation of three-dimensional OCT data, thus enabling precise registration of OCT measurements to retinal fundus features. CONCLUSIONS. High-speed, ultrahigh-resolution OCT enables imaging of retinal architectural morphology in small animal models. OCT fundus images allow precise registration of OCT images and repeated measurements with respect to retinal fundus features. Three-dimensional OCT imaging enables visualization and quantification of retinal structure, which promises to allow repeated, noninvasive measurements to track disease progression, thereby reducing the need for killing the animal for histology. This capability can accelerate basic research studies in rats and mice and their translation into clinical patient care.
引用
收藏
页码:5522 / 5528
页数:7
相关论文
共 33 条
  • [1] Ultrahigh resolution optical coherence tomography of the monkey fovea. Identification of retinal sublayers by correlation with semithin histology sections
    Anger, EM
    Unterhuber, A
    Hermann, B
    Sattmann, H
    Schubert, C
    Morgan, JE
    Cowey, A
    Ahnelt, PK
    Drexler, W
    [J]. EXPERIMENTAL EYE RESEARCH, 2004, 78 (06) : 1117 - 1125
  • [2] Full-field optical coherence microscopy
    Beaurepaire, E
    Boccara, AC
    Lebec, M
    Blanchot, L
    Saint-Jalmes, H
    [J]. OPTICS LETTERS, 1998, 23 (04) : 244 - 246
  • [3] Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography
    Cense, B
    Nassif, NA
    Chen, T
    Pierce, M
    Yun, SH
    Park, BH
    Bouma, BE
    Tearney, GJ
    de Boer, JF
    [J]. OPTICS EXPRESS, 2004, 12 (11): : 2435 - 2447
  • [4] In vivo ultrahigh-resolution optical coherence tomography
    Drexler, W
    Morgner, U
    Kärtner, FX
    Pitris, C
    Boppart, SA
    Li, XD
    Ippen, EP
    Fujimoto, JG
    [J]. OPTICS LETTERS, 1999, 24 (17) : 1221 - 1223
  • [5] Enhanced visualization of macular pathology with the use of ultrahigh-resolution optical coherence tomography
    Drexler, W
    Sattmarin, H
    Hermann, B
    Ko, TH
    Stur, M
    Unterhuber, A
    Scholda, C
    Findl, O
    Wirtitsch, M
    Fujimoto, JG
    Fercher, AF
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (05) : 695 - 706
  • [6] Ultrahigh-resolution ophthalmic optical coherence tomography
    Drexler, W
    Morgner, U
    Ghanta, RK
    Kärtner, FX
    Schuman, JS
    Fujimoto, JG
    [J]. NATURE MEDICINE, 2001, 7 (04) : 502 - 507
  • [7] Three-dimensional cellular-level imaging using full-field optical coherence tomography
    Dubois, A
    Moneron, G
    Grieve, K
    Boccara, AC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (07) : 1227 - 1234
  • [8] Assessment of central visual function in Stargardt's disease/fundus flavimaculatus with ultrahigh-resolution optical coherence tomography
    Ergun, E
    Hermann, B
    Wirtitsch, M
    Unterhuber, A
    Ko, TH
    Sattmann, H
    Scholda, C
    Fujimoto, JG
    Stur, M
    Drexler, W
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (01) : 310 - 316
  • [9] MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY
    FERCHER, AF
    HITZENBERGER, CK
    KAMP, G
    ELZAIAT, SY
    [J]. OPTICS COMMUNICATIONS, 1995, 117 (1-2) : 43 - 48
  • [10] Histologic correlation of pig retina radial stratification with ultrahigh-resolution optical coherence tomography
    Gloesmann, M
    Hermann, B
    Schubert, C
    Sattmann, H
    Ahnelt, PK
    Drexler, W
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (04) : 1696 - 1703