Data-driven techniques for fault detection in anaerobic digestion process

被引:61
|
作者
Kazemi, Pezhman [1 ]
Bengoa, Christophe [1 ]
Steyer, Jean-Philippe [2 ]
Giralt, Jaume [1 ]
机构
[1] Univ Rovira & Virgili, Dept Engn Quim, Avda Paisos Catalans 26, Tarragona 43007, Spain
[2] Univ Montpellier, LBE, INRA, 102 Ave Etangs, F-11100 Narbonne, France
关键词
BSM2; Bootstrapping; Anaerobic digestion; Soft-sensor; Neural network; CUSUM chart; BENCHMARK SIMULATION-MODEL; WASTE-WATER; NEURAL-NETWORK; DIAGNOSIS; PREDICTION; SEARCH; SIZE;
D O I
10.1016/j.psep.2020.12.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Anaerobic digestion (AD) is an appropriate process for bio-energy (biogas) production from waste and wastewater receiving a high level of attention at both academic and industrial scale due to increasing public awareness regarding environmental protection and energy security. Monitoring such processes is an imperative task to ensure optimized operation and prevent failures and serious consequences during the operation of the plant. To fulfill this task, a practical data-driven framework for fault detection in AD is proposed and validated on a simulated data set obtained using the benchmark simulation model No.2 (BSM2) from the International Water Association (IWA). The proposed framework is based on data-driven soft-sensors predicting total volatile fatty acids (VFA), mainly consisting of acetate, propionate, valerate and butyrate concentrations inside the digester. The VFA concentration is considered because it does not only reflect the current process health, but it is also sensitive to the incoming feeding imbalances. VFA soft-sensors using different advanced techniques such as support vector machine (SVM), extreme learning machine (ELM) and ensemble of neural network (ENN) are tested and compared in terms of accuracy and fault detection (FD) robustness. A principal component analysis (PCA) model was also developed to compare the proposed approaches with the traditional FD method. By applying soft-sensors, the residual signal, i.e., the difference between estimated and measured VFA values can be generated. This residual signal can then be used in combination with univariate statistical control charts to detect the faults. A comparison of the proposed FD framework with PCA method clearly demonstrates the over performance and feasibility of the proposed monitoring framework. (C) 2020 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:905 / 915
页数:11
相关论文
共 50 条
  • [41] TrackSafe: A comparative study of data-driven techniques for automated railway track fault detection using image datasets
    Minguell, Marta Garcia
    Pandit, Ravi
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2023, 125
  • [42] Data-driven fault detection and isolation scheme for a wind turbine benchmark
    de Bessa, Iury Valente
    Palhares, Reinaldo Martinez
    Silveira Vasconcelos D'Angelo, Marcos Flavio
    Chaves Filho, Joao Edgar
    RENEWABLE ENERGY, 2016, 87 : 634 - 645
  • [43] Machine learning and data-driven fault detection for ship systems operations
    Cheliotis, Michail
    Lazakis, Iraklis
    Theotokatos, Gerasimos
    OCEAN ENGINEERING, 2020, 216
  • [44] A novel data-driven methodology for fault detection and dynamic risk assessment
    Amin, Md. Tanjin
    Khan, Faisal
    Ahmed, Salim
    Imtiaz, Syed
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2020, 98 (11) : 2397 - 2416
  • [45] Machine learning technique for data-driven fault detection of nonlinear processes
    Said, Maroua
    ben Abdellafou, Khaoula
    Taouali, Okba
    JOURNAL OF INTELLIGENT MANUFACTURING, 2020, 31 (04) : 865 - 884
  • [46] A data-driven fault detection approach for static processes with deterministic disturbances
    Luo, Hao
    Ding, Steven X.
    Zhang, Kai
    Yin, Shen
    2014 IEEE 23RD INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2014, : 2404 - 2409
  • [47] Data-Driven Fault Detection and Isolation of the Actuators of an Autonomous Underwater Vehicle
    Castaldi, Paolo
    Farsoni, Saverio
    Menghini, Massimiliano
    Simani, Silvio
    5TH CONFERENCE ON CONTROL AND FAULT-TOLERANT SYSTEMS (SYSTOL 2021), 2021, : 139 - 144
  • [48] A data-driven hybrid sensor fault detection/diagnosis method with flight test data
    Song, Jinsheng
    Chen, Ziqiao
    Wang, Dong
    Wen, Xin
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (07)
  • [49] Neuronal Modeling of a Two Stages Anaerobic Digestion Process for Biofuels Production
    Aguirre Camberos, S. U.
    Gurubel, K. J.
    Sanchez, E. N.
    Alarcon Aguirre, S.
    Gonzalez Perez, R.
    IFAC PAPERSONLINE, 2018, 51 (13): : 408 - 413
  • [50] Biogas production estimation using data-driven approaches for cold region municipal wastewater anaerobic digestion
    Asadi, Mohsen
    Guo, Huiqing
    McPhedran, Kerry
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2020, 253