Data-driven techniques for fault detection in anaerobic digestion process

被引:61
|
作者
Kazemi, Pezhman [1 ]
Bengoa, Christophe [1 ]
Steyer, Jean-Philippe [2 ]
Giralt, Jaume [1 ]
机构
[1] Univ Rovira & Virgili, Dept Engn Quim, Avda Paisos Catalans 26, Tarragona 43007, Spain
[2] Univ Montpellier, LBE, INRA, 102 Ave Etangs, F-11100 Narbonne, France
关键词
BSM2; Bootstrapping; Anaerobic digestion; Soft-sensor; Neural network; CUSUM chart; BENCHMARK SIMULATION-MODEL; WASTE-WATER; NEURAL-NETWORK; DIAGNOSIS; PREDICTION; SEARCH; SIZE;
D O I
10.1016/j.psep.2020.12.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Anaerobic digestion (AD) is an appropriate process for bio-energy (biogas) production from waste and wastewater receiving a high level of attention at both academic and industrial scale due to increasing public awareness regarding environmental protection and energy security. Monitoring such processes is an imperative task to ensure optimized operation and prevent failures and serious consequences during the operation of the plant. To fulfill this task, a practical data-driven framework for fault detection in AD is proposed and validated on a simulated data set obtained using the benchmark simulation model No.2 (BSM2) from the International Water Association (IWA). The proposed framework is based on data-driven soft-sensors predicting total volatile fatty acids (VFA), mainly consisting of acetate, propionate, valerate and butyrate concentrations inside the digester. The VFA concentration is considered because it does not only reflect the current process health, but it is also sensitive to the incoming feeding imbalances. VFA soft-sensors using different advanced techniques such as support vector machine (SVM), extreme learning machine (ELM) and ensemble of neural network (ENN) are tested and compared in terms of accuracy and fault detection (FD) robustness. A principal component analysis (PCA) model was also developed to compare the proposed approaches with the traditional FD method. By applying soft-sensors, the residual signal, i.e., the difference between estimated and measured VFA values can be generated. This residual signal can then be used in combination with univariate statistical control charts to detect the faults. A comparison of the proposed FD framework with PCA method clearly demonstrates the over performance and feasibility of the proposed monitoring framework. (C) 2020 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:905 / 915
页数:11
相关论文
共 50 条
  • [31] Data-driven approach to fault detection for hospital HVAC system
    Aghili, Seyed Abolfazl
    Khanzadi, Mostafa
    Haji Mohammad Rezaei, Amin
    Rahbar, Morteza
    SMART AND SUSTAINABLE BUILT ENVIRONMENT, 2024,
  • [32] A Data-driven Fault Detection Toolbox Based on Matlab GUIDE
    Sun, Bowen
    Wang, Jiongqi
    Hou, Bowen
    Xu, Shuqing
    Zhang, Kun
    He, Zhangming
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 4326 - 4331
  • [33] Data-Driven Schemes for Robust Fault Detection of Air Data System Sensors
    Fravolini, Mario L.
    del Core, Giuseppe
    Papa, Umberto
    Valigi, Paolo
    Napolitano, Marcello R.
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2019, 27 (01) : 234 - 248
  • [34] Data-driven Crowd Modeling Techniques: A Survey
    Zhong, Jinghui
    Li, Dongrui
    Huang, Zhixing
    Lu, Chengyu
    Cai, Wentong
    ACM TRANSACTIONS ON MODELING AND COMPUTER SIMULATION, 2022, 32 (01):
  • [35] Data-driven fault detection for chemical processes using autoencoder with data augmentation
    Lee, Hodong
    Kim, Changsoo
    Jeong, Dong Hwi
    Lee, Jong Min
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2021, 38 (12) : 2406 - 2422
  • [36] Data-Driven Techniques in Disaster Information Management
    Li, Tao
    Xie, Ning
    Zeng, Chunqiu
    Zhou, Wubai
    Zheng, Li
    Jiang, Yexi
    Yang, Yimin
    Ha, Hsin-Yu
    Xue, Wei
    Huang, Yue
    Chen, Shu-Ching
    Navlakha, Jainendra
    Iyengar, S. S.
    ACM COMPUTING SURVEYS, 2017, 50 (01)
  • [37] Data-driven model for feedstock blending optimization of anaerobic co-digestion by BMP maximization
    Moretta, Federico
    Goracci, Alessia
    Manenti, Flavio
    Bozzano, Giulia
    JOURNAL OF CLEANER PRODUCTION, 2022, 375
  • [38] Input selection methods for data-driven Soft sensors design: Application to an industrial process
    Curreri, Francesco
    Graziani, Salvatore
    Xibilia, Maria Gabriella
    INFORMATION SCIENCES, 2020, 537 : 1 - 17
  • [39] Data-driven approaches for impending fault detection of industrial systems: a review
    Patil, Amitkumar
    Soni, Gunjan
    Prakash, Anuj
    INTERNATIONAL JOURNAL OF SYSTEM ASSURANCE ENGINEERING AND MANAGEMENT, 2024, 15 (04) : 1326 - 1344
  • [40] A Lightweight and Explainable Data-Driven Scheme for Fault Detection of Aerospace Sensors
    Li, Zhongzhi
    Zhang, Yiming
    Ai, Jianliang
    Zhao, Yunmei
    Yu, Yushu
    Dong, Yiqun
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2023, 59 (06) : 8392 - 8410