Changes in Corneal Biomechanical Properties After Descemet Stripping Automated Endothelial Keratoplasty for Pseudophakic Bullous Keratopathy

被引:9
作者
Faramarzi, Amir
Feizi, Sepehr
Najdi, Danial
Ghiasian, Leila
Karimian, Farid
机构
[1] Shahid Beheshti Univ Med Sci, Ophthalm Res Ctr, Labbafinejad Med Ctr, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Dept Ophthalmol, Labbafinejad Med Ctr, Tehran, Iran
关键词
INTRAOCULAR-PRESSURE; DYNAMIC CONTOUR; THICKNESS; HYSTERESIS; TONOMETRY; EYES;
D O I
10.1097/ICO.0000000000000684
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare corneal biomechanical properties and intraocular pressure (IOP) in eyes with pseudophakic bullous keratopathy (PBK) before and after Descemet stripping automated endothelial keratoplasty (DSAEK). Methods: This prospective nonrandomized intrasubject comparative study was conducted on 44 eyes of 22 patients with the diagnosis of PBK who underwent DSAEK in one eye. IOP was measured by Goldmann applanation tonometer, and central corneal thickness was measured by ultrasound pachymetry. The ocular response analyzer was used to measure corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-related IOP, and cornea-compensated IOP. The same measurements were performed in the normal fellow eyes which served as controls. All measurements were performed preoperatively and 6 months postoperatively. Results: The mean patient age was 67 ± 14 years. Mean preoperative CH and CRF values in the DSAEK group were 5.77 ± 2.94 and 6.39 ± 2.72 mm Hg, respectively, which were significantly lower than those measured in the control group (8.2 ± 2.47 and 8.43 ± 2.49 mm Hg, respectively, P 0.001 for both comparisons). Postoperatively, CH and CRF demonstrated a significant increase (7.09 ± 3.68 mm Hg, P 0.05 and 8.21 ± 3.84 mm Hg, P 0.03, respectively) in operated eyes approaching the normal values measured in the control eyes. Conclusions: Corneal biomechanical parameters were significantly lower in PBK eyes than in the normal fellow eyes. These metrics significantly increased after DSAEK and reached values measured in the normal fellow eyes. Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:20 / 24
页数:5
相关论文
共 25 条
[1]   Influence of different keratoplasty techniques on the biomechanical properties of the cornea [J].
Abdelkader, Almamoun .
ACTA OPHTHALMOLOGICA, 2013, 91 (07) :E567-E572
[2]   Risk Factors for Intraocular Pressure Elevation After Descemet Stripping Automated Endothelial Keratoplasty [J].
Allen, Meredith B. ;
Lieu, Philip ;
Mootha, V. Vinod ;
Bowman, R. Wayne ;
Petroll, W. Matthew ;
Tong, Liyue ;
Kooner, Karanjit S. ;
Cavanagh, H. Dwight ;
Whitson, Jess T. ;
Aggarwal, Nalini K. .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2010, 36 (04) :223-227
[3]   Comparison of Dynamic Contour Tonometry with Goldmann Applanation Tonometry following Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) [J].
Bochmann, F. ;
Kaufmann, C. ;
Becht, C. ;
Bachmann, L. M. ;
Thiel, M. A. .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2009, 226 (04) :241-244
[4]   The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology [J].
Browning, AC ;
Bhan, A ;
Rotchford, AP ;
Shah, S ;
Dua, HS .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (11) :1395-1399
[5]   Corneal Thickness and Intraocular Pressure in Edematous Corneas Before and After Descemet Stripping With Automated Endothelial Keratoplasty [J].
Chang, Diane T. W. ;
Pantcheva, Mina B. ;
Noecker, Robert J. .
CORNEA, 2010, 29 (10) :1125-1130
[6]   Intraocular pressure and corneal biomechanics in Fuchs' endothelial dystrophy and after posterior lamellar keratoplasty [J].
Clemmensen, Kare ;
Hjortdal, Jesper .
ACTA OPHTHALMOLOGICA, 2014, 92 (04) :350-354
[7]   Biomechanical Properties of the Cornea in Fuchs' Corneal Dystrophy [J].
del Buey, Maria A. ;
Cristobal, Jose A. ;
Ascaso, Francisco J. ;
Lavilla, Laura ;
Lanchares, Elena .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (07) :3199-3202
[8]   Intraocular pressure changes following Descemet's stripping with endothelial keratoplasty [J].
Espana, Edgar M. ;
Robertson, Zachary M. ;
Huang, Bo .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (02) :237-242
[9]   Changes in corneal hysteresis after clear corneal cataract surgery [J].
Hager, Annette ;
Loge, Kristina ;
Fuellhas, Marc-Oliver ;
Schroeder, Ernd ;
Grossherr, Martin ;
Wiegand, Wolfgang .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (03) :341-346
[10]  
HJORTDAL JO, 1995, ACTA OPHTHALMOL SCAN, V73, P12