Determination of cysteine in a pharmaceutical formulation by flow injection analysis with a chemiluminescence detector

被引:96
|
作者
Lau, CW [1 ]
Qin, XJ [1 ]
Liang, HY [1 ]
Lu, HZ [1 ]
机构
[1] Fudan Univ, Sch Pharm, Shanghai 200032, Peoples R China
关键词
cysteine; chemiluminescence; flow injection; pharmaceutical formulation;
D O I
10.1016/j.aca.2004.01.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and convenient flow injection-chemiluminescence (FI-CL) method for the determination of cysteine is reported, based on a fast and strong CL in a basic luminol-cysteine-NaIO4 solution. The linear range was 1.0 x 10(-8) to 1.0 X 10(-6) M with a detection limit (3s) of 5 x 10(-9) M, which was 100 times more sensitive than previously reported CL methods. Singlet oxygen, hydroxyl radical and hydrogen peroxide were suggested to be produced in this reaction and were responsible for the CL of cysteine. This simple method has been successfully applied for the determination of cysteine in a pharmaceutical formulation. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 50 条
  • [31] Determination of Ceftriaxone Sodium in Pharmaceutical Formulations by Flow Injection Analysis with Acid Potassium Permanganate Chemiluminescence Detection
    Deyi Zhang
    Yongjun Ma
    Min Zhou
    Li Li
    Hui Chen
    Analytical Sciences, 2006, 22 : 183 - 186
  • [32] Chemiluminescence determination of streptomycin in pharmaceutical preparation and its application to pharmacokinetic study by a flow injection analysis assembly
    Du, Bin
    Li, Hongyan
    Jin, Jianwen
    Wang, Tiantian
    Li, Yang
    Shen, Guopeng
    Li, Xiaotian
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2013, 115 : 823 - 828
  • [33] Determination of ceftriaxone sodium in pharmaceutical formulations by flow injection analysis with acid potassium permanganate chemiluminescence detection
    Zhang, DY
    Ma, YJ
    Zhou, M
    Li, L
    Chen, H
    ANALYTICAL SCIENCES, 2006, 22 (01) : 183 - 186
  • [34] Flow injection determination of acetylsalicylic acid in pharmaceutical preparations with an amperometric detector
    Garrido, JMPJ
    Lima, JLFC
    Matos, CD
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2000, 65 (06) : 954 - 962
  • [35] A Simple Flow Injection Spectrophotometric Procedure for the Determination of Diazepam in Pharmaceutical Formulation
    S. Liawruangrath
    Jirayu Makchit
    B. Liawruangrath
    Analytical Sciences, 2006, 22 : 127 - 130
  • [36] A simple flow injection spectrophotometric procedure for the determination of diazepam in pharmaceutical formulation
    Liawruangrath, S
    Makchit, J
    Liawruangrath, B
    ANALYTICAL SCIENCES, 2006, 22 (01) : 127 - 130
  • [37] Determination of hydrogen peroxide by flow injection-chemiluminescence using a novel flow-cell reactor in a chemiluminescence detector
    Kawamoto, H
    Nozaki, O
    BUNSEKI KAGAKU, 1999, 48 (05) : 471 - 476
  • [38] Determination of Cytochrome c in Human Serum and Pharmaceutical Injections Using Flow Injection Chemiluminescence
    Li, Xin
    Liu, Houyong
    He, Xili
    Song, Zhenghua
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2010, 160 (04) : 1065 - 1073
  • [39] Determination of Picogram Levels of Levodopa in Pharmaceutical Preparations and Biofluids by Flow-Injection Chemiluminescence
    Zhang, Yun
    Gao, Suya
    BIOTECHNOLOGY, CHEMICAL AND MATERIALS ENGINEERING III, PTS 1 AND 2, 2014, 884-885 : 566 - 569
  • [40] Determination of Cytochrome c in Human Serum and Pharmaceutical Injections Using Flow Injection Chemiluminescence
    Xin Li
    Houyong Liu
    Xili He
    Zhenghua Song
    Applied Biochemistry and Biotechnology, 2010, 160 : 1065 - 1073