Refractometer assessment of colostral and serum IgG and milk total solids concentrations in dairy cattle

被引:29
作者
Chigerwe, Munashe [1 ]
Hagey, Jill V. [1 ]
机构
[1] Univ Calif Davis, Sch Vet Med, Dept Med & Epidemiol, Davis, CA 95616 USA
来源
BMC VETERINARY RESEARCH | 2014年 / 10卷
关键词
Colostrum; Milk; Serum; Immunoglobulin; Milk total solids; PASSIVE TRANSFER; IMMUNOGLOBULIN CONCENTRATIONS; HOLSTEIN; IMMUNOASSAY; HYDROMETER;
D O I
10.1186/s12917-014-0178-7
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: Estimation of the quantity of colostral IgG or serum IgG absorbed following ingestion of colostrum by calves is essential for monitoring the effectiveness of colostrum feeding practices on dairy farms. Milk total solids concentrations determination is a critical part of quality assessment of nonsaleable whole milk prior to feeding to calves. To date, on-farm methods to assess colostral IgG, serum IgG or milk total solids concentrations have been performed separately with various instruments. The objective of this study was to evaluate the diagnostic performance of a single electronic, hand-held refractometer for assessing colostral and serum IgG concentrations and milk total solids in dairy cattle. Colostral IgG, serum IgG and milk total solids concentrations were determined by the refractometer. Corresponding analysis of colostral and serum IgG concentrations were determined by radial immunodiffusion ( RID) while milk total solids were determined by spectrophotometry. Sensitivity and specificity of the refractometer for colostrum and serum samples were calculated as determined by RID. Sensitivity and specificity of the refractometer for milk samples was calculated as determined by spectrophotometry. Results: The sensitivity of the refractometer was 1 for colostral IgG, serum IgG and milk total solids determinations. Specificity of the refractometer was 0.66, 0.24 and 0 for colostral IgG, serum IgG and milk total solids determinations, respectively. The refractometer underestimated colostral IgG, serum IgG and milk total solids concentrations compared to the concentrations determined by RID or spectrophotometry. Conclusions: The refractometer was an acceptable, rapid, convenient on-farm method for determining colostral IgG and milk total solids. The refractometer was not an acceptable method for determination of serum IgG concentrations as it severely underestimated the serum IgG concentrations.
引用
收藏
页数:6
相关论文
共 31 条
[1]   Short communication: Evaluation of serum immunoglobulin G concentrations using an automated turbidimetric immunoassay in dairy calves [J].
Alley, M. L. ;
Haines, D. M. ;
Smith, G. W. .
JOURNAL OF DAIRY SCIENCE, 2012, 95 (08) :4596-4599
[2]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[3]  
BESSER TE, 1991, J AM VET MED ASSOC, V198, P419
[4]   VARIATION IN SERUM CONCENTRATIONS OF IMMUNOGLOBULIN-G, IMMUNOGLOBULIN-A, AND IMMUNOGLOBULIN-M IN CANADIAN HOLSTEIN-FRIESIAN CALVES [J].
BURTON, JL ;
KENNEDY, BW ;
BURNSIDE, EB ;
WILKIE, BN ;
BURTON, JH .
JOURNAL OF DAIRY SCIENCE, 1989, 72 (01) :135-149
[5]   Evaluation of a cow-side immunoassay kit for assessing IgG concentration in colostrum [J].
Chigerwe, M ;
Dawes, ME ;
Tyler, JW ;
Middleton, JR ;
Moore, MP ;
Nagy, DM .
JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2005, 227 (01) :129-131
[6]   Effect of colostrum administration by use of oroesophageal intubation on serum IgG concentrations in Holstein bull calves [J].
Chigerwe, Munashe ;
Tyler, Jeff W. ;
Schultz, Loren G. ;
Middleton, John R. ;
Steevens, Barry J. ;
Spain, James N. .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2008, 69 (09) :1158-1163
[7]   Comparison of four methods to assess colostral IgG concentration in dairy cows [J].
Chigerwe, Munashe ;
Tyler, Jeff W. ;
Middleton, John R. ;
Spain, James N. ;
Dill, Jeffrey S. ;
Steevens, Barry J. .
JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2008, 233 (05) :761-766
[8]  
FAHEY JL, 1965, J IMMUNOL, V94, P84
[9]   HYDROMETER TEST FOR ESTIMATION OF IMMUNOGLOBULIN CONCENTRATION IN BOVINE COLOSTRUM [J].
FLEENOR, WA ;
STOTT, GH .
JOURNAL OF DAIRY SCIENCE, 1980, 63 (06) :973-977
[10]   AVAILABILITY, STORAGE, TREATMENT, COMPOSITION, AND FEEDING VALUE OF SURPLUS COLOSTRUM - REVIEW [J].
FOLEY, JA ;
OTTERBY, DE .
JOURNAL OF DAIRY SCIENCE, 1978, 61 (08) :1033-1060