Clinical evaluation of manual and automatic exposure control techniques in film-based chest radiography

被引:8
作者
Ismailos, E
Mastorakou, I
Kelekis, NL
Papadopoulos, KP
Efstathopoulos, EP
Panayiotakis, G
Kelekis, DA
机构
[1] ONASSIS CARDIAC SURG CTR,GR-17674 ATHENS,GREECE
[2] UNIV PATRAS,SCH HLTH SCI,DEPT MED PHYS,PATRAS,GREECE
关键词
D O I
10.1259/0007-1285-69-823-650
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chest radiographs obtained with either automatic exposure control (AEC) technique. or manual exposure control (MEG) technique. were compared in a sample of 329 cardiological and cardiosurgery patients. Parameters evaluated, a-ere various anatomical regions, according to their appearance in both posteroanterior (PA) and lateral radiographs. Lateral radiographs obtained with the AEC technique demonstrated better image quality than those obtained with the manual technique. There was no definite advantage of the AEC technique in PA radiographs. The AEC technique has the potential to improve the quality of lateral chest radiographs of cardiological and cardiosurgery patients. It is considered to be a useful tool in chest radiography.
引用
收藏
页码:650 / 654
页数:5
相关论文
共 10 条
[1]   A DETAILED STUDY OF RADIATION-DOSE AND RADIOGRAPHIC TECHNIQUE DURING CHEST RADIOGRAPHY [J].
FAULKNER, K ;
GORDON, MDH ;
MILLER, J .
BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (699) :245-249
[2]   EVALUATION OF A NEW MOBILE AUTOMATIC EXPOSURE CONTROL DEVICE [J].
FISHER, MR ;
MINTZER, RA ;
ROGERS, LF ;
LIN, PJP ;
BOVA, JB ;
DOERNER, SM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (06) :1055-1059
[3]   STORAGE PHOSPHOR RADIOGRAPHS VS CONVENTIONAL FILMS - INTERPRETERS PERCEPTIONS OF DIAGNOSTIC QUALITY [J].
FUHRMAN, CR ;
GUR, D ;
GOOD, B ;
ROCKETTE, H ;
COOPERSTEIN, LA ;
FEIST, JH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (05) :1011-1014
[4]  
GARRETT JA, 1988, ASSURANCE QUALITY DI
[5]   DIGITAL AND CONVENTIONAL CHEST IMAGES - OBSERVER PERFORMANCE WITH FILM DIGITAL RADIOGRAPHY SYSTEM [J].
GOODMAN, LR ;
FOLEY, WD ;
WILSON, CR ;
RIMM, AA ;
LAWSON, TL .
RADIOLOGY, 1986, 158 (01) :27-33
[6]  
GOODMAN LR, 1992, CRITICAL CARE IMAGIN, P269
[7]  
KING JL, 1991, SOC PHOTOOPTICAL INS, V1446, P268
[8]   TECHNICAL ADVANCES IN CHEST RADIOGRAPHY [J].
MACMAHON, H ;
VYBORNY, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) :1049-1059
[9]  
ORT M G, 1979, Medical Physics (Woodbury), V6, P134, DOI 10.1118/1.594541
[10]   AMBER - A SCANNING MULTIPLE-BEAM EQUALIZATION SYSTEM FOR CHEST RADIOGRAPHY [J].
VLASBLOEM, H ;
KOOL, LJS .
RADIOLOGY, 1988, 169 (01) :29-34