FATIGUE RESISTANCE OF CAD/CAM COMPLETE CROWNS WITH A SIMPLIFIED CEMENTATION PROCESS

被引:70
作者
Carvalho, Adriana O. [1 ]
Bruzi, Greciana [2 ]
Giannini, Marcelo [1 ]
Magne, Pascal [3 ]
机构
[1] Univ Estadual Campinas, Piracicaba Sch Dent, Dept Restorat Dent, Piracicaba, SP, Brazil
[2] Univ Fed Santa Catarina, Dept Operat Dent, Florianopolis, SC, Brazil
[3] Univ So Calif, Ostrow Sch Dent, Los Angeles, CA USA
关键词
ENDODONTICALLY TREATED MOLARS; FINITE-ELEMENT-ANALYSIS; COMPOSITE RESIN; RESTORATIVE MATERIALS; OCCLUSAL VENEERS; DENTAL MATERIALS; ADHESIVE; MICROLEAKAGE; BRITTLENESS; PORCELAIN;
D O I
10.1016/j.prosdent.2013.09.020
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Various computer-aided design and computer-aided manufacturing (CAD/CAM) materials are available to fabricate complete crowns. The type of material may have an effect on the longevity of these restorations. Purpose. To evaluate the fatigue resistance, load-to-failure, failure mode, and antagonistic wear of complete molar computer-aided design and computer-aided manufacturing (CAD/CAM) crowns made of resin nanoceramic (RNC), feldspathic glass ceramic (FEL), or lithium disilicate (LD) placed with a simplified cementation process. Material and methods. Forty-five molars received a standardized complete crown preparation and were restored with CAD/CAM crowns (1.5-mm thickness, n=15) made of RNC, FEL, and LD. After cementation, the restorations were submitted to cyclic isometric loading: 200 (x5000), 400, 600, 800, 1000, 1200, and 1400 N at a maximum of 30 000 cycles each. Surviving specimens were axially loaded until failure or to a maximum load of 4500 N. The specimens were analyzed as to failure mode: catastrophic, possibly repairable, and repairable. The groups were compared by using the life table survival analysis and the t test (alpha=.05). Results. All the specimens survived the fatigue process until the 800-N step. The survival rate of RNC was 80%, LD 93.3%, and FEL 6.6%. The survival of RNC and LD crowns did not differ from each other but exceeded that of FEL. Postfatigue load-tofailure test was 2500 N (FEL), 3122 N (RNC), and 3237 N (LD). No catastrophic failure occurred in the fatigue test, whereas all of the specimens in the load-to-failure test exhibited catastrophic fractures. Crowns made of RNC seemed to generate the least amount of antagonistic wear. Conclusions. Posterior crowns made of RNC and LD were not statistically different, and both had significantly higher fatigue resistance than FEL. All materials survived beyond the normal range of masticatory forces, and all failures were possibly re-restorable except those in the load-to-failure test. RNC crowns seemed to cause less wear of the antagonist.
引用
收藏
页码:310 / 317
页数:8
相关论文
共 50 条
  • [41] Microleakage of Different Self-Adhesive Materials for Lithium Disilicate CAD/CAM Crowns
    Naumova, Ella A.
    Valta, Alexander
    Schaper, Katharina
    Arnold, Wolfgang. H.
    Piwowarczyk, Andree
    MATERIALS, 2015, 8 (06): : 3238 - 3253
  • [42] Accelerated Fatigue Resistance of Thick CAD/CAM Composite Resin Overlays Bonded with Light- and Dual-polymerizing Luting Resins
    Goldberg, Jack
    Guth, Jan-Frederik
    Magne, Pascal
    JOURNAL OF ADHESIVE DENTISTRY, 2016, 18 (04) : 341 - 348
  • [43] The effect of finish line curvature on marginal fit of all-ceramic CAD/CAM crowns and metal-ceramic crowns
    Tao, Jianxiang
    Han, Dongwei
    QUINTESSENCE INTERNATIONAL, 2009, 40 (09): : 745 - 752
  • [44] Effect of Two Self-Adhesive Cements on Marginal Adaptation and Strength of Esthetic Ceramic CAD/CAM Molar Crowns
    Moermann, Werner
    Wolf, Daniel
    Ender, Andreas
    Bindl, Andreas
    Goehring, Till
    Attin, Thomas
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (05): : 403 - 410
  • [45] Toothbrushing Wear Resistance of Stained CAD/CAM Ceramics
    Dal Piva, Amanda Maria de Oliveira
    Bottino, Marco Antonio
    Anami, Lilian Costa
    Werner, Arie
    Kleverlaan, Cornelis Johannes
    Lo Giudice, Roberto
    Fama, Fausto
    da Silva-Concilio, Lais Regiane
    Tribst, Joao Paulo Mendes
    COATINGS, 2021, 11 (02) : 1 - 13
  • [46] Effect of thickness and CAD-CAM material on fatigue resistance of endodontically treated molars restored with occlusal veneers
    Noronha, Mayara dos Santos
    de Carvalho, Marco Aurelio
    Anh Quynh Do
    de Araujo Neto, Vitaliano Gomes
    Campos, Camila Heitor
    Giannini, Marcelo
    Magne, Pascal
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (02): : E19 - E29
  • [47] Fatigue Resistance of 3-Unit CAD-CAM Ceramic Fixed Partial Dentures: An FEA Study
    Bataineh, Khaled
    Al Janaideh, Mohammad
    Abu-Naba'a, Layla A.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (09): : 806 - 814
  • [48] Minimally invasive CAD/CAM lithium disilicate partial-coverage restorations show superior in-vitro fatigue performance than single crowns
    Spitznagel, F. A.
    Prott, L. S.
    Hoppe, J. S.
    Manitckaia, T.
    Blatz, M. B.
    Zhang, Y.
    Langner, R.
    Gierthmuehlen, P. C.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (01) : 94 - 106
  • [49] In-vitro performance of CAD/CAM-fabricated implant-supported temporary crowns
    Rosentritt, Martin
    Raab, Philipp
    Hahnel, Sebastian
    Stoeckle, Matthias
    Preis, Verena
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (08) : 2581 - 2587
  • [50] Influence of microscale expansion and contraction caused by thermal and mechanical fatigue on retentive strength of CAD/CAM-generated resin-based composite crowns
    Ankyu, Shuhei
    Nakamura, Keisuke
    Harada, Akio
    Inagaki, Ryoichi
    Katsuda, Yusuke
    Kanno, Taro
    Niwano, Yoshimi
    Ortengren, Ulf
    Egusa, Hiroshi
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 86 : 89 - 97