FATIGUE RESISTANCE OF CAD/CAM COMPLETE CROWNS WITH A SIMPLIFIED CEMENTATION PROCESS

被引:70
作者
Carvalho, Adriana O. [1 ]
Bruzi, Greciana [2 ]
Giannini, Marcelo [1 ]
Magne, Pascal [3 ]
机构
[1] Univ Estadual Campinas, Piracicaba Sch Dent, Dept Restorat Dent, Piracicaba, SP, Brazil
[2] Univ Fed Santa Catarina, Dept Operat Dent, Florianopolis, SC, Brazil
[3] Univ So Calif, Ostrow Sch Dent, Los Angeles, CA USA
关键词
ENDODONTICALLY TREATED MOLARS; FINITE-ELEMENT-ANALYSIS; COMPOSITE RESIN; RESTORATIVE MATERIALS; OCCLUSAL VENEERS; DENTAL MATERIALS; ADHESIVE; MICROLEAKAGE; BRITTLENESS; PORCELAIN;
D O I
10.1016/j.prosdent.2013.09.020
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Various computer-aided design and computer-aided manufacturing (CAD/CAM) materials are available to fabricate complete crowns. The type of material may have an effect on the longevity of these restorations. Purpose. To evaluate the fatigue resistance, load-to-failure, failure mode, and antagonistic wear of complete molar computer-aided design and computer-aided manufacturing (CAD/CAM) crowns made of resin nanoceramic (RNC), feldspathic glass ceramic (FEL), or lithium disilicate (LD) placed with a simplified cementation process. Material and methods. Forty-five molars received a standardized complete crown preparation and were restored with CAD/CAM crowns (1.5-mm thickness, n=15) made of RNC, FEL, and LD. After cementation, the restorations were submitted to cyclic isometric loading: 200 (x5000), 400, 600, 800, 1000, 1200, and 1400 N at a maximum of 30 000 cycles each. Surviving specimens were axially loaded until failure or to a maximum load of 4500 N. The specimens were analyzed as to failure mode: catastrophic, possibly repairable, and repairable. The groups were compared by using the life table survival analysis and the t test (alpha=.05). Results. All the specimens survived the fatigue process until the 800-N step. The survival rate of RNC was 80%, LD 93.3%, and FEL 6.6%. The survival of RNC and LD crowns did not differ from each other but exceeded that of FEL. Postfatigue load-tofailure test was 2500 N (FEL), 3122 N (RNC), and 3237 N (LD). No catastrophic failure occurred in the fatigue test, whereas all of the specimens in the load-to-failure test exhibited catastrophic fractures. Crowns made of RNC seemed to generate the least amount of antagonistic wear. Conclusions. Posterior crowns made of RNC and LD were not statistically different, and both had significantly higher fatigue resistance than FEL. All materials survived beyond the normal range of masticatory forces, and all failures were possibly re-restorable except those in the load-to-failure test. RNC crowns seemed to cause less wear of the antagonist.
引用
收藏
页码:310 / 317
页数:8
相关论文
共 50 条
  • [21] In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns
    Preis, Verena
    Hahnel, Sebastian
    Behr, Michael
    Bein, Laila
    RosentrittDepartment, Martin
    DENTAL MATERIALS, 2017, 33 (04) : 427 - 433
  • [22] In vitro evaluation of the marginal integrity of CAD/CAM interim crowns
    Khng, Kwang Yong Kelvin
    Ettinger, Ronald L.
    Armstrong, Steven R.
    Lindquist, Terry
    Gratton, David G.
    Qian, Fang
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (05) : 617 - 623
  • [23] Predicting the Debonding of CAD/CAM Composite Resin Crowns with AI
    Yamaguchi, S.
    Lee, C.
    Karaer, O.
    Ban, S.
    Mine, A.
    Imazato, S.
    JOURNAL OF DENTAL RESEARCH, 2019, 98 (11) : 1234 - 1238
  • [24] Evaluation of the On Vitro Effects of Cervical Marginal Relocation Using Composite Resins on the Marginal Quality of CAD/CAM Crowns
    Spreafico, Roberto
    Marchesi, Giulio
    Turco, Gianluca
    Frassetto, Andrea
    Di Lenarda, Roberto
    Mazzoni, Annalisa
    Cadenaro, Milena
    Breschi, Lorenzo
    JOURNAL OF ADHESIVE DENTISTRY, 2016, 18 (04) : 355 - 362
  • [25] Fracture Resistance of Molar Crowns Fabricated with Monolithic All-Ceramic CAD/CAM Materials Cemented on Titanium Abutments: An In Vitro Study
    Dogan, Derya Ozdemir
    Gorler, Oguzhan
    Mutaf, Burcu
    Ozcan, Mutlu
    Eyuboglu, Gunes Bulut
    Ulgey, Melih
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (04): : 309 - 314
  • [26] IN VITRO FATIGUE RESISTANCE OF CAD/CAM COMPOSITE RESIN AND CERAMIC POSTERIOR OCCLUSAL VENEERS
    Magne, Pascal
    Schlichting, Luis Henrique
    Maia, Hamilton Pires
    Baratieri, Luiz Narciso
    JOURNAL OF PROSTHETIC DENTISTRY, 2010, 104 (03) : 149 - 157
  • [27] An investigation on fatigue, fracture resistance, and color properties of aesthetic CAD/CAM monolithic ceramics
    Ahmed Mahmoud Fouda
    Osama Atta
    Mutlu Özcan
    Bogna Stawarczyk
    Robert Glaum
    Christoph Bourauel
    Clinical Oral Investigations, 2023, 27 : 2653 - 2665
  • [28] An investigation on fatigue, fracture resistance, and color properties of aesthetic CAD/CAM monolithic ceramics
    Fouda, Ahmed Mahmoud
    Atta, Osama
    Ozcan, Mutlu
    Stawarczyk, Bogna
    Glaum, Robert
    Bourauel, Christoph
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (06) : 2653 - 2665
  • [29] Fracture resistance of CAD/CAM occlusal veneers: A systematic review of laboratory studies
    Albelasy, Eman H.
    Hamama, Hamdi H.
    Tsoi, James K. H.
    Mahmoud, Salah H.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 110
  • [30] Fracture resistance of CAD-CAM all-ceramic surveyed crowns with different occlusal rest seat designs
    Chaturvedi, Saurabh
    Alqahtani, Turki
    Alsolami, Saleh
    Alqahtani, Abdulbari
    Das, Gotam
    Alsubaiy, Ebrahim
    JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (01) : 36 - 45