A sequential injection lab-at-valve (SI-LAV) platform for hydride generation atomic absorption spectrometry (HG-AAS): on-line determination of inorganic arsenic

被引:13
作者
Anthemidis, Aristidis N. [1 ]
Daftsis, Emmanouil I. [1 ]
Kalogiouri, Natasa P. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Analyt Chem Lab, Thessaloniki 54124, Greece
关键词
FLUORESCENCE SPECTROMETRY; ON-VALVE; ENVIRONMENTAL-SAMPLES; SPECIATION ANALYSIS; BEAD INJECTION; SYSTEM; EXTRACTION; SELENIUM;
D O I
10.1039/c3ay42159g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel automatic low-cost sequential injection lab-at-valve (SIA-LAV) system has been developed for inorganic arsenic determination coupled with hydride generation atomic absorption spectrometry (HG-AAS). The proposed manifold includes an integrated gas-liquid separator/reaction chamber (GLS-RC) which was attached to one port of a conventional six-port multiposition selection valve. The arsine vapour is generated by injecting reductant NaBH4 into the GLS-RC, minimizing its dispersion and possible losses. All critical parameters affecting the efficiency of the system were studied and optimised. For 3.0 mL sample consumption the detection limit was 0.05 mu g L-1 and the precision expressed as RSD was 3.2%. The proposed method was evaluated in comparison with a reference flow injection HG method and applied for arsenic determination in environmental water samples. The recovery was estimated by spiking the samples and it ranged from 95.5% up to 102.5% for both As(III) and As(V).
引用
收藏
页码:2745 / 2750
页数:6
相关论文
共 31 条
[1]  
[Anonymous], WHOSDEWSH030475REV1
[2]  
[Anonymous], 1998, Compendium of Analytical Nomenclature: Definitive Rules, V3rd
[3]  
[Anonymous], 2001, Federal Register, V66, P6975
[4]   Development of a sequential injection system for trace mercury determination by cold vapour atomic absorption spectrometry utilizing an integrated gas-liquid separator/reactor [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2004, 64 (04) :1053-1057
[5]   Determination of arsenic(III) and total inorganic arsenic in water samples using an on-line sequential insertion system and hydride generation atomic absorption spectrometry [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
ANALYTICA CHIMICA ACTA, 2005, 547 (02) :237-242
[6]   Determination of arsenic(III) by flow injection solid phase extraction coupled with on-line hydride generation atomic absorption spectrometry using a PTFE turnings-packed micro-column [J].
Anthemidis, Aristidis N. ;
Martavaltzoglou, Evdoxia K. .
ANALYTICA CHIMICA ACTA, 2006, 573 :413-418
[7]   Advances in On-Line Hydride Generation Atomic Spectrometric Determination of Arsenic [J].
Anthemidis, Aristidis N. ;
Kalogiouri, Natasa P. .
ANALYTICAL LETTERS, 2013, 46 (11) :1672-1704
[8]  
APHA, 2013, Standard Methods for the Examination of Water and Wastewater
[9]   On-line speciation analysis of inorganic arsenic in complex environmental aqueous samples by pervaporation sequential injection analysis [J].
Boonjob, Warunya ;
Miro, Manuel ;
Kolev, Spas D. .
TALANTA, 2013, 117 :8-13
[10]   Exploiting sequential injection analysis with lab-at-valve (LAV) approach for on-line liquid-liquid micro-extraction spectrophotometry [J].
Burakham, R ;
Lapanantnoppakhun, S ;
Jakmunee, J ;
Grudpan, K .
TALANTA, 2005, 68 (02) :416-421