Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part II. High dose rate 192Ir sources

被引:20
作者
Fulkerson, Regina K. [1 ]
Micka, John A. [1 ]
DeWerd, Larry A. [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
关键词
skin cancer; surface applicator; HDR; LEIPZIG APPLICATORS; AAPM PROTOCOL; RECOMMENDATIONS; CALIBRATION; PARAMETERS;
D O I
10.1118/1.4862506
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR) Ir-192 sources, as well as electronic brachytherapy sources. Part I of this paper discussed the applicators used with electronic brachytherapy sources. Part II will discuss those used with HDR Ir-192 sources. Although the use of these applicators has gained in popularity, the dosimetric characteristics have not been independently verified. Additionally, there is no recognized method of output verification for quality assurance procedures with applicators like these. Methods: This work aims to create a cohesive method of output verification that can be used to determine the dose at the treatment surface as part of a quality assurance/commissioning process for surface applicators used with HDR electronic brachytherapy sources (Part I) and Ir-192 sources (Part II). Air-kerma rate measurements for the Ir-192 sources were completed with several models of small-volume ionization chambers to obtain an air-kerma rate at the treatment surface for each applicator. Correction factors were calculated using MCNP5 and EGSnrc Monte Carlo codes in order to determine an applicator-specific absorbed dose to water at the treatment surface from the measured air-kerma rate. Additionally, relative dose measurements of the surface dose distributions and characteristic depth dose curves were completed in-phantom. Results: Theoretical dose distributions and depth dose curves were generated for each applicator and agreed well with the measured values. A method of output verification was created that allows users to determine the applicator-specific dose to water at the treatment surface based on a measured air-kerma rate. Conclusions: The novel output verification methods described in this work will reduce uncertainties in dose delivery for treatments with these kinds of surface applicators, ultimately improving patient care. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:16
相关论文
共 32 条
  • [21] Comparison of Axxent-Xoft, 192Ir and 60Co high-dose-rate brachytherapy sources for image-guided brachytherapy treatment planning for cervical cancer
    Mobit, P. N.
    Packianathan, S.
    He, R.
    Yang, C. C.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1052)
  • [22] A comparative assessment of inhomogeneity and finite patient dimension effects in 60Co and 192Ir high-dose-rate brachytherapy
    Fotina, Irina
    Zourari, Kyveli
    Lahanas, Vasileios
    Pantelis, Evaggelos
    Papagiannis, Panagiotis
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2018, 10 (01) : 73 - 84
  • [23] Suitability of the microDiamond detector for experimental determination of the anisotropy function of High Dose Rate192Ir brachytherapy sources
    Rossi, Giulio
    Gainey, Mark
    Kollefrath, Michael
    Hofmann, Elena
    Baltas, Dimos
    [J]. MEDICAL PHYSICS, 2020, 47 (11) : 5838 - 5851
  • [24] Treatment planning study of the 3D dosimetric differences between Co-60 and Ir-192 sources in high dose rate (HDR) brachytherapy
    Palmer, Antony
    Hayman, Orla
    Muscat, Sarah
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2012, 4 (01) : 52 - 59
  • [25] A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192Ir brachytherapy
    Ma, Yunzhi
    Vijande, Javier
    Ballester, Facundo
    Tedgren, Asa Carlsson
    Granero, Domingo
    Haworth, Annette
    Mourtada, Firas
    Fonseca, Gabriel Paiva
    Zourari, Kyveli
    Papagiannis, Panagiotis
    Rivard, Mark J.
    Siebert, Frank-Andre
    Sloboda, Ron S.
    Smith, Ryan
    Chamberland, Marc J. P.
    Thomson, Rowan M.
    Verhaegen, Frank
    Beaulieu, Luc
    [J]. MEDICAL PHYSICS, 2017, 44 (11) : 5961 - 5976
  • [26] Monte Carlo study of TG-43 dosimetry parameters of GammaMed Plus high dose rate 192Ir brachytherapy source using TOPAS
    Wu, Jianan
    Xie, Yaoqin
    Ding, Zhen
    Li, Feipeng
    Wang, Luhua
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (06): : 146 - 153
  • [27] Absorbed dose simulations in near-surface regions using high dose rate Iridium-192 sources applied for brachytherapy
    Moura, E. S.
    Zeituni, C. A.
    Sakuraba, R. K.
    Goncalves, V. D.
    Cruz, J. C.
    Junior, D. K.
    Souza, C. D.
    Rostelato, M. E. C. M.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 299 - 301
  • [28] Dedicated high dose rate 192Ir brachytherapy radiation fields for in vitro cell exposures at variable source-target cell distances: killing of mammalian cells depends on temporal dose rate fluctuation
    Veigel, Cornelia
    Hartmann, Guenther H.
    Fritz, Peter
    Debus, Juergen
    Weber, Klaus-Josef
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (04) : 1613 - 1631
  • [29] High Dose Rate 192-Ir-Brachytherapy for Basal Cell Carcinoma of the Skin using a 3D Printed Surface Mold
    Casey, Stephanie
    Bahl, Gaurav
    Awotwi-Pratt, Joseph B.
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (06)
  • [30] Calibration of TLD-100 powder by energies of 60Co, 137Cs, 192Ir and RX of 250, 50 kVp in a dose absorbed in water with aims to control the dosimetric quality by high dosage rate brachytherapy
    Calderon, S. P. Loaiza
    Romero, J. T. Alvarez
    [J]. REVISTA MEXICANA DE FISICA, 2006, 52 (05) : 413 - 421