A high current electron cyclotron resonance proton ion source is designed and developed for the low energy high intensity proton accelerator at Bhabha Atomic Research Centre. The plasma discharge in the ion source is stabilized by minimizing the reflected microwave power using four stub auto tuner and magnetic field. The optimization of extraction geometry is performed using PBGUNS code by varying the aperture, shape, accelerating gap, and the potential on the electrodes. While operating the source, it was found that the two layered microwave window (6 mm quartz plate and 2 mm boron nitride plate) was damaged (a fine hole was drilled) by the back-streaming electrons after continuous operation of the source for 3 h at beam current of 20-40 mA. The microwave window was then shifted from the line of sight of the back-streaming electrons and located after the water-cooled H-plane bend. In this configuration the stable operation of the high current ion source for several hours is achieved. The ion beam is extracted from the source by biasing plasma electrode, puller electrode, and ground electrode to +10 to +50 kV, -2 to -4 kV, and 0 kV, respectively. The total ion beam current of 30-40 mA is recorded on Faraday cup at 40 keV of beam energy at 600-1000 W of microwave power, 800-1000 G axial magnetic field and (1.2-3.9) x 10(-3) mbar of neutral hydrogen gas pressure in the plasma chamber. The dependence of beam current on extraction voltage, microwave power, and gas pressure is investigated in the range of operation of the ion source. (C) 2014 AIP Publishing LLC.
引用
收藏
页数:10
相关论文
共 11 条
[1]  
Boers J. E., 1995, Proceedings of the 1995 Particle Accelerator Conference (Cat. No.95CH35843), P2312, DOI 10.1109/PAC.1995.505535
[2]   Enhancement of ion current from the TRIPS source by means of different electron donors [J].
Gammino, S ;
Ciavola, G ;
Celona, L ;
Torrisi, L ;
Mascali, D ;
Passarello, S ;
Galatà, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03)
[3]   Preliminary results of the International Fusion Materials Irradiation Facility deuteron injector [J].
Gobin, R. ;
Adroit, G. ;
Bogard, D. ;
Bourdelle, G. ;
Chauvin, N. ;
Delferriere, O. ;
Gauthier, Y. ;
Girardot, P. ;
Guiho, P. ;
Harrault, F. ;
Jannin, J. L. ;
Loiseau, D. ;
Mattei, P. ;
Roger, A. ;
Sauce, Y. ;
Senee, F. ;
Vacher, T. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02)
[4]   High intensity ECR ion source (H+, D+, H-) developments at CEA/Saclay [J].
Gobin, R ;
Beauvais, PY ;
Bogard, D ;
Charruau, G ;
Delferrière, O ;
De Menezes, D ;
France, A ;
Ferdinand, R ;
Gauthier, Y ;
Harrault, F ;
Jannin, JL ;
Lagniel, JM ;
Leroy, PA ;
Mattéi, P ;
Sherman, J ;
Sinanna, A ;
Ausset, P ;
Bousson, S ;
Pottin, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02) :922-924
[5]   Diagnostics of microwave ECR generated plasma: Effect of contaminated reference electrode [J].
Kar, R. ;
Barve, S. A. ;
Singh, S. B. ;
Barve, D. N. ;
Chand, N. ;
Patil, D. S. .
VACUUM, 2010, 85 (02) :151-155
[6]   Temperature diagnostics of ECR plasma by measurement of electron bremsstrahlung [J].
Kasthurirangan, S. ;
Agnihotri, A. N. ;
Desai, C. A. ;
Tribedi, L. C. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (07)
[7]   Currents limited by space charge between concentric spheres [J].
Langmuir, I ;
Blodgett, KB .
PHYSICAL REVIEW, 1924, 24 (01) :49-59
[8]   Langmuir probe diagnostics of plasma in high current electron cyclotron resonance proton ion source [J].
Roychowdhury, P. ;
Kewlani, H. ;
Mishra, L. ;
Patil, D. S. ;
Mittal, K. C. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (07)
[9]   High intensity electron cyclotron resonance proton source for low energy high intensity proton accelerator [J].
Roychowdhury, P. ;
Chakravarthy, D. P. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (12)
[10]   A 75 keV, 140 mA proton injector [J].
Sherman, JD ;
Figueroa, TL ;
Hansborough, LD ;
Kerstiens, DM ;
Schneider, JD ;
Smith, HV ;
Stettler, MW ;
Stevens, RR ;
Thuot, ME ;
Warren, DS ;
Zaugg, TJ ;
Arvin, AA ;
Bolt, AS ;
Boers, JE .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02) :917-921