Cyclotorsional eye movements during a simulated PRK procedure

被引:7
作者
Fea, A. M. [1 ]
Sciandra, L. [1 ]
Annetta, F. [1 ]
Musso, M. [1 ]
Dal Vecchio, M. [1 ]
Grignolo, F. M. [1 ]
机构
[1] Univ Turin, Clin Oculist, Dipartimento Fisiopatol Clin, I-10100 Turin, Italy
关键词
cyclotorsional movements; excimer laser; videoculography;
D O I
10.1038/sj.eye.6701994
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Eye alignment is a serious concern when performing corneal surface ablation. Although several excimer lasers monitor horizontal and vertical movements, little is known about the potential impact of cyclotorsional movements. Dynamic cyclotorsions have been measured on 10 emmetropic subjects during a simulated PRK treatment. Methods Cyclotorsional eye movements were measured using a 3D videoculographic system (SMI) in 10 emmetropic subjects in upright and supine position. The subjects were wearing an eyelid speculum and were asked to fixate on a 11 red spot. The fixation target was either in focus or optically degraded by electronic filters. Data were collected at the University Eye Clinic, Torino, Italy, and the different setting measurements were compared using Student's t-test for paired data. Results Cyclotorsions were significantly higher when subjects were fixating an optically degraded stimulus (upright: P = 0.04; supine: P = 0.0002). The cyclotorsional movements ranged from -13 to 17 degrees. A significant difference in eye orientation was present when changing from the upright to the supine position (P = 0.03). Even when correcting for this positional error, significantly higher cyclotorsional movements were detected in the supine position (in focus: P = 0.0043; optically degraded: P = 0.0008). The torsional range was from -14.85 to 14.55 degrees. Conclusions The high range of cyclotorsional eye movements during a simulated PRK procedure suggests that 3D tracking could improve surface ablation results when treating high astigmatism or when wavefront guided.
引用
收藏
页码:764 / 768
页数:5
相关论文
共 12 条
[1]   Use of preoperative assessment of positionally induced cyclotorsion: a video-oculographic study [J].
Becker, R ;
Krzizok, TH ;
Wassill, H .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (03) :417-421
[2]   Cyclotorsional eye motion occurring between wavefront measurement and refractive surgery [J].
Chernyak, DA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (03) :633-638
[3]   EVALUATION OF A VIDEO TRACKING DEVICE FOR MEASUREMENT OF HORIZONTAL AND VERTICAL EYE ROTATIONS DURING LOCOMOTION [J].
DISCENNA, AO ;
DAS, V ;
ZIVOTOFSKY, AZ ;
SEIDMAN, SH ;
LEIGH, RJ .
JOURNAL OF NEUROSCIENCE METHODS, 1995, 58 (1-2) :89-94
[4]  
GERTEN G, 21 C ESCRS MUN 6 10
[5]  
GORDES RS, 2002, OPHTHALMOLOGE S1, V99, P142
[6]   Changes in cyclotorsion and vertical eye alignment during prolonged monocular occlusion [J].
Graf, EW ;
Maxwell, JS ;
Schor, CM .
VISION RESEARCH, 2002, 42 (09) :1185-1194
[7]   Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations [J].
Guirao, A ;
Williams, DR ;
Cox, IG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (05) :1003-1015
[8]   Rotational malposition during laser in situ keratomileusis [J].
Swami, AU ;
Steinert, RF ;
Osborne, WE ;
White, AA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 133 (04) :561-562
[9]  
Teiwes W, 1997, 3 DIMENSIONAL KINEMA, P429
[10]   Cyclotorsion: A possible cause of residual astigmatism in refractive surgery [J].
Tjon-Fo-Sang, MJ ;
de Faber, JTHN ;
Kingma, C ;
Beekhuis, WH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (04) :599-602