Development of a plug-type IMS-MS instrument and its applications in resolving problems existing in in-situ detection of illicit drugs and explosives by IMS

被引:45
作者
Du, Zhenxia [1 ]
Sun, Tangqiang [1 ]
Zhao, Jianan [1 ]
Wang, Di [1 ]
Zhang, Zhongxia [2 ]
Yu, Wenlian [3 ]
机构
[1] Beijing Univ Chem Technol, Coll Sci, Beijing Key Lab Environm Harmful Chem Anal, Beijing, Peoples R China
[2] Nuctech Co Ltd, Beijing 100084, Peoples R China
[3] Chinese Acad Inspect & Quarantine, Beijing, Peoples R China
关键词
Ion mobility spectrometry (IMS); Tandem mass spectrometry(MS); Explosives; Illicit drugs; False response; ION MOBILITY SPECTROMETRY; MASS-SPECTROMETRY; TRACE DETECTOR; CHEMICAL STANDARDS; GAS; CHEMISTRY; SAMPLES; COMPLEX; MODE; AIR;
D O I
10.1016/j.talanta.2018.02.086
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion mobility spectrometry (IMS) which acts as a rapid analysis technique is widely used in the field detection of illicit drugs and explosives. Due to limited separation abilities of the pint-sized IMS challenges and problems still exist regarding high false positive and false negative responses due to the interference of the matrix. In addition, the gas -phase ion chemistry and special phenomena in the IMS spectra, such one substance showing two peaks, were not identified unambiguously. In order to explain or resolve these questions, in this paper, an ion mobility spectrometry was coupled to a mass spectrometry (IMS-MS). A commercial IMS is embedded in a custom-built ion chamber shell was attached to the mass spectrometer. The faraday plate of IMS was fabricated with a hole for the ions to passing through to the mass spectrometer. The ion transmission efficiency of IMS-MS was optimized by optimizing the various parameters, especially the distance between the faraday plate and the cone of mass spectrum. This design keeps the integrity of the two original instruments and the mass spectrometry still works with multimode ionization source (i.e., IMS-MS, ESI-MS, APCI-MS modes). The illicit drugs and explosive samples were analyzed by the IMS-MS with 63Ni source. The results showed that the IMS-MS is of high sensitivity. The ionization mechanism of the illicit drug and explosive samples with 63Ni source were systematically studied. In addition, the interferent which interfered the detection of cocaine was identified as dibutyl phthalate (DBP) by this platform. The reason why the acetone solution of amphetamine showed two peaks was explained.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 35 条
  • [1] [Anonymous], 2005, ION MOBILITY SPECTRO, DOI DOI 10.1201/9781420038972
  • [2] Structures of Metallosupramolecular Coordination Assemblies Can Be Obtained by Ion Mobility Spectrometry-Mass Spectrometry
    Brocker, Erin R.
    Anderson, Stanley E.
    Northrop, Brian H.
    Stang, Peter J.
    Bowers, Michael T.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2010, 132 (38) : 13486 - 13494
  • [3] Ion mobility spectrometry rediscovered
    Cottingham, K
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (19) : 435A - 439A
  • [4] The role of oxygen in the formation of TNT product ions in ion mobility spectrometry
    Daum, KA
    Atkinson, DA
    Ewing, RG
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 214 (02) : 257 - 267
  • [5] Resolving interferences in negative mode ion mobility spectrometry using selective reactant ion chemistry
    Daum, KA
    Atkinson, DA
    Ewing, RG
    Knighton, WB
    Grimsrud, EP
    [J]. TALANTA, 2001, 54 (02) : 299 - 306
  • [6] Migration of phthalate and non-phthalate plasticizers out of plasticized PVC films into air
    Demir, A. P. Tuzum
    Ulutan, S.
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 2013, 128 (03) : 1948 - 1961
  • [7] Validation of an ion mobility spectrometry (IMS) method for the detection of heroin and cocaine on incriminated material
    Dussy, Franz E.
    Berchtold, Christian
    Briellmann, Thomas A.
    Lang, Candid
    Steiger, Rene
    Bovens, Michael
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2008, 177 (2-3) : 105 - 111
  • [8] Ion mobility spectrometers in national defense.
    Eiceman, GA
    Stone, JA
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (21) : 390A - 397A
  • [9] Chemical standards in ion mobility spectrometry
    Eiceman, GA
    Nazarov, EG
    Stone, JA
    [J]. ANALYTICA CHIMICA ACTA, 2003, 493 (02) : 185 - 194
  • [10] A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds
    Ewing, RG
    Atkinson, DA
    Eiceman, GA
    Ewing, GJ
    [J]. TALANTA, 2001, 54 (03) : 515 - 529