Performance Evaluation of a Domestic Refrigerator with a Thermal Storage arrangement Using Propane as a Refrigerant

被引:10
作者
Niyaj, Shikalgar D. [1 ]
Sapali, S. N. [2 ]
机构
[1] Coll Engn Pune, Dept Mech Engn, Pune, Maharashtra, India
[2] Coll Engn Pune, Dept Mech Engn, Pune, Maharashtra, India
来源
INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016 | 2017年 / 109卷
关键词
Domestic Refrigerator; Evaporator; Phase change Material; Propane;
D O I
10.1016/j.egypro.2017.03.045
中图分类号
O414.1 [热力学];
学科分类号
摘要
In developing countries like India, a general problem relates to frequent power breakdown, which gives augment to the spoiling of unpreserved items such as medicine and foodstuff due to lack of a passive cold retention system. Moreover, the rural India is subjected to maximum isolation due to power cuts for many hours and even days. The paper has an attempt to tackle this problem by developing a domestic refrigerator system capable of maintaining the cooling effect for more than 15 hours without energy input and being compact as well as cost-effective. The second objective was to reduce the global warming potential caused by HCFC refrigerant. Taking into account the very needs of an average rural household in India, the required cooling load is estimated. The system was designed and analyzed using R290 ( Propane) as a refrigerant by replacing R134a. The theoretical and experimental analysis of 45 liter domestic refrigerators using R290 as a refrigerant is carried out. The R290 is a replacement for R134a and R22 refrigerants. The Phase change material ( PCM) is located in the newly designed evaporator in order to improve its efficiency and provide a storage capacity allowing a number of hours of refrigeration without energy supply. The system has been tested with Ethylene Glycol as a PCM with and without thermal load. Results show that the refrigerant R290 have a slightly lower coefficient of performance than R134a for the condensation temperature of 35 degrees C to 43 degrees C and evaporating temperatures range between - 5 degrees C to 5 degrees C. Depending on the load in the refrigerator with PCM the average compressor running time per cycle is reduced significantly and it is in the range of 17% to 20% as compared with refrigerator without PCM. The coefficient of performance of refrigeration systems with R290 as refrigerant is comparable with R134a as a refrigerant and starting torque of compressor reduces which leads to improvement in a life span of the compressor. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:34 / 39
页数:6
相关论文
共 11 条
  • [1] [Anonymous], INT J THERMAL SCI
  • [2] [Anonymous], 9 INT C PHAS CHANG M
  • [3] [Anonymous], INT J REFRIGERATION
  • [4] [Anonymous], 1997, KYOTO PROTOCOL UN FR
  • [5] [Anonymous], 23 INT C REFR CZECH
  • [6] [Anonymous], 1987, MONTREAL PROTOCOL SU
  • [7] [Anonymous], T FAMENA
  • [8] Performance enhancement of a household refrigerator by addition of latent heat storage
    Azzouz, K.
    Leducq, D.
    Gobin, D.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (05): : 892 - 901
  • [9] Enhancing the performance of household refrigerators with latent heat storage: An experimental investigation
    Azzouz, K.
    Leducq, D.
    Gobin, D.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (07): : 1634 - 1644
  • [10] Azzouz K, 2005, P 2 C PHAS CHANG MAT