MiniMed 670G hybrid closed loop artificial pancreas system for the treatment of type 1 diabetes mellitus: overview of its safety and efficacy

被引:43
作者
Saunders, Aria [1 ]
Messer, Laurel H. [2 ]
Forlenza, Gregory P. [2 ]
机构
[1] Univ Colorado, Dept Bioengn, Denver, CO 80202 USA
[2] Univ Colorado, Barbara Davis Ctr, Aurora, CO USA
关键词
Artificial pancreas (AP); automated insulin delivery; continuous glucose monitor (CGM); hybrid closed loop; insulin pump; MiniMed; 670G; type; 1; diabetes; GLUCOSE MONITORING TECHNOLOGY; INSULIN DELIVERY; HOME USE; ADULTS; FEASIBILITY; ADOLESCENTS; FRAMEWORK; CHILDREN; EXERCISE; THERAPY;
D O I
10.1080/17434440.2019.1670639
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Automated insulin delivery for people with type 1 diabetes has been a major goal in the diabetes technology field for many years. While a fully automated system has not yet been accomplished, the MiniMed? 670G artificial pancreas (AP) system is the first commercially available insulin pump that automates basal insulin delivery, while still requiring user input for insulin boluses. Determining the safety and efficacy of this system is essential to the development of future devices striving for more automation. Areas Covered: This review will provide an overview of how the MiniMed 670G system works including its safety and efficacy, how it compares to similar devices, and anticipated future advances in diabetes technology currently under development. Expert Opinion: The ultimate goal of advanced diabetes technologies is to reduce the burden and amount of management required of patients with diabetes. In addition to reducing patient workload, achieving better glucose control and improving hemoglobin A1c (HbA1c) values are essential for reducing the threat of diabetes-related complications further down the road. Current devices come close to reaching these goals, but understanding the unmet needs of patients with diabetes will allow future technologies to achieve these goals more quickly.
引用
收藏
页码:845 / 853
页数:9
相关论文
共 50 条
  • [41] A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
    El-Khatib, Firas H.
    Russell, Steven J.
    Nathan, David M.
    Sutherlin, Robert G.
    Damiano, Edward R.
    SCIENCE TRANSLATIONAL MEDICINE, 2010, 2 (27) : 27ra27
  • [42] A retrospective analysis of 24-month real-world glucose control for children and adolescents with type 1 diabetes using the MiniMed™ 670G insulin pump
    Delvecchio, Maurizio
    Galati, Alessio
    Maffeis, Claudio
    Passanisi, Stefano
    Bonfanti, Riccardo
    Franceschi, Roberto
    Tornese, Gianluca
    Calzi, Elena
    Zanfardino, Angela
    Bracciolini, Giulia Patrizia
    Piccinno, Elvira
    SPED Diabetes Study Grp
    DIABETES OBESITY & METABOLISM, 2023, 25 (04) : 1101 - 1105
  • [43] Efficacy of advanced hybrid closed loop systems for the management of type 1 diabetes in children
    Ferrito, Lucia
    Passanisi, Stefano
    Bonfanti, Riccardo
    Cherubini, Valentino
    Minuto, Nicola
    Schiaffini, Riccardo
    Scaramuzza, Andrea
    MINERVA PEDIATRICS, 2021, 73 (06): : 474 - 485
  • [44] Analysis of "Hybrid Closed Loop Using a Do-It-Yourself Artificial Pancreas System in Adults With Type 1 Diabetes"
    Wilkinson, Tom M.
    de Bock, Martin
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (04): : 897 - 898
  • [45] Optimizing a Hybrid Closed Loop System in Type 1 Diabetes: A Case Report
    Petrovski, Goran
    Al Khalaf, Fawziya
    Hussain, Khalid
    Campbell, Judith
    DIABETES THERAPY, 2018, 9 (05) : 2173 - 2177
  • [46] Artificial pancreas for type 1 diabetes: Closed-loop algorithm based on Error Dynamics Shaping
    Cormerais, H.
    Richard, P. -Y.
    JOURNAL OF PROCESS CONTROL, 2012, 22 (07) : 1219 - 1227
  • [47] MiniMed 780G™ advanced hybrid closed-loop system performance in Egyptian patients with type 1 diabetes across different age groups: evidence from real-world users
    Elbarbary, Nancy Samir
    Ismail, Eman Abdel Rahman
    DIABETOLOGY & METABOLIC SYNDROME, 2023, 15 (01)
  • [48] The psychosocial outcomes of advanced hybrid closed-loop system in children and adolescents with type 1 diabetes
    Jalilova, Arzu
    Pilan, Birsen Senturk
    Demir, Gunay
    Ozbaran, Burcu
    Balki, Hanife Gul
    Arslan, Emrullah
    Kose, Sezen Gokcen
    Ozen, Samim
    Darcan, Sukran
    Goksen, Damla
    EUROPEAN JOURNAL OF PEDIATRICS, 2024, 183 (07) : 3095 - 3103
  • [49] Efficacy of the Diabeloop closed-loop system to improve glycaemic control in patients with type 1 diabetes exposed to gastronomic dinners or to sustained physical exercise
    Hanaire, Helene
    Franc, Sylvia
    Borot, Sophie
    Penfornis, Alfred
    Benhamou, Pierre-Yves
    Schaepelynck, Pauline
    Renard, Eric
    Guerci, Bruno
    Jeandidier, Nathalie
    Simon, Chantal
    Hannaert, Patrick
    Xhaard, Ilham
    Doron, Maeva
    Huneker, Erik
    Charpentier, Guillaume
    Reznik, Yves
    DIABETES OBESITY & METABOLISM, 2020, 22 (03) : 324 - 334
  • [50] Glycemic outcomes of Advanced Hybrid Closed Loop system in children and adolescents with Type 1 Diabetes, previously treated with Multiple Daily Injections (MiniMed 780G system in T1D individuals, previously treated with MDI)
    Petrovski, Goran
    Al Khalaf, Fawziya
    Campbell, Judith
    Day, Emma
    Almajaly, Douha
    Hussain, Khalid
    Pasha, Maheen
    Umer, Fareeda
    Hamdan, Manar
    Khalifa, Amel
    BMC ENDOCRINE DISORDERS, 2022, 22 (01)