Perfusion CT is able to outline blood perfusion changes in a tissue. Thus, in lesions of the tissues of the pancreas, this offers to increase the accuracy of CT diagnosis. In this study, our aim was to explore the perfusion characteristics of normal pancreas and pancreatic adenocarcinoma. Dynamic 64-slice helical CT was conducted in 36 patients with non-pancreatic disease and in 40 patients with histopathologically proven pancreatic adenocarcinoma. Perfusion parameters including blood flow (BF), blood volume (BV), and permeability surface area product (PS) were recorded. There was no significant difference noted between the distribution of BF, BV, and PS values in different regions of the pancreas, namely the head, neck, body, and tail (P > 0.05). The BF, BV, and PS of normal pancreas were recorded as 135.24 +/- A 48.36 ml min(-1) 100 g(-1), 200.55 +/- A 54.96 ml 100 g(-1), and 49.75 +/- A 24.27 ml min(-1) 100 g(-1), respectively. BF, BV, and PS values of the tumor tissue of pancreatic adenocarcinoma decreased significantly compared to normal pancreas (P < 0.05). Normal pancreas appears homogenous on perfusion CT. A significant decrease of BF, BV, and PS was observed in pancreatic adenocarcinoma. Dynamic 64-slice helical CT with perfusion imaging should be considered a potential modality to increase the accuracy of CT diagnosis for pancreatic adenocarcinoma.
引用
收藏
页码:759 / 766
页数:8
相关论文
共 50 条
  • [21] A case of coronary artery fistula visualized by 64-slice multidetector CT
    Versaci, Francesco
    Del Giudice, Costantino
    Sperandio, Massimiliano
    Simonetti, Giovanni
    Chiariello, Luigi
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2009, 6 (01): : 57 - 60
  • [22] Caseous Calcification of the Mitral Annulus Imaged with 64-slice Multidetector CT
    Biteker, Murat
    Duran, Niluefer Eksi
    Oezkan, Mehmet
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (06): : 744 - 745
  • [23] Clinical application of 64-slice spiral CT in the diagnosis of the Tetralogy of Fallot
    Wang, Xi-Ming
    Wu, Le-Bin
    Sun, Cong
    Liu, Cheng
    Chao, Bao-Ting
    Han, Bo
    Zhang, Yun-Ting
    Chen, Hai-Song
    Li, Zhen-Jia
    EUROPEAN JOURNAL OF RADIOLOGY, 2007, 64 (02) : 296 - 301
  • [24] Computed tomography perfusion imaging evaluation of angiogenesis in patients with pancreatic adenocarcinoma
    Liu, Wen
    Yin, Bo
    Liang, Zong-Hui
    Yu, Yang
    Lu, Na
    WORLD JOURNAL OF CLINICAL CASES, 2022, 10 (08) : 2393 - 2403
  • [25] Characterization of Solid Renal Masses using 64-Slice Multidetector CT Scanner
    El-Esawy, Saleh S.
    Abou El-Ghar, Mohamed E.
    Gaballa, Ghada M.
    Zahra, Saly A.
    THESCIENTIFICWORLDJOURNAL, 2009, 9 : 441 - 448
  • [26] Comparison of helical CT and MR imaging in detecting and staging small pancreatic adenocarcinoma
    Irie, H
    Honda, H
    Kaneko, K
    Kuroiwa, T
    Yoshimitsu, K
    Masuda, K
    ABDOMINAL IMAGING, 1997, 22 (04): : 429 - 433
  • [27] Anatomic variations and anomalies of the coronary arteries: 64-slice CT angiographic appearance
    Kosar, Pinar
    Ergun, Elif
    Ozturk, Cansu
    Kosar, Ugur
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2009, 15 (04): : 275 - 283
  • [28] Reconstruction of the portal vein with 64-slice spiral CT of bile duct obstruction
    Xia, Yunbao
    Pan, Gongmao
    Xue, Feng
    Geng, Chengjun
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 6 (02) : 401 - 406
  • [29] Coronary artery fistulas in children. Evaluation with 64-slice multidetector CT
    Hu, X.
    Wu, L.
    Liu, F.
    Shen, Q.
    Pa, M.
    Huang, G.
    HERZ, 2013, 38 (07) : 729 - 735
  • [30] A survey of the current status of coronary CT angiography using 64-slice multidetector CT in Taiwan
    Jeng, Chin-Ming
    Wu, Ming-Ting
    Wang, Pa-Chun
    Chan, Tiffany
    Wan, Yung-Liang
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2014, 113 (02) : 124 - 132