THE ELECTROCHEMICAL PROPERTIES OF FOUR DENTAL CASTING SUPRASTRUCTURE ALLOYS COUPLED WITH TITANIUM IMPLANTS

被引:13
作者
Tuna, Suleyman Hakan [1 ]
Pekmez, Nuran Ozcicek [2 ]
Keyf, Filiz [3 ]
Canli, Fulya [2 ]
机构
[1] Suleyman Demirel Univ, Dept Prosthodont, Fac Dent, TR-32200 Isparta, Turkey
[2] Hacettepe Univ, Dept Chem, Fac Sci, TR-06532 Ankara, Turkey
[3] Hacettepe Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
关键词
Corrosion; Dental casting alloys; Titanium implant; Electrochemical properties; Galvanic corrosion; CORROSION BEHAVIOR; METAL-IONS; ABUTMENTS; PH;
D O I
10.1590/S1678-77572009000500022
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: As the choice of suprastructure alloy to be combined with titanium for the oral cavity is still a much debated issue, the aim of this study was to investigate the electrochemical interaction of the suprastructure/implant couples under the determined experiment conditions. Material and Methods: The potentiodynamic polarization curves and open-circuit potentials (OCP) of four UCLA type suprastructures coupled with straight Swiss Plus implant fixtures were taken in Afnor type artificial saliva solution at 37 degrees C. The concentration of ions leached into artificial saliva solutions was estimated with ICP-MS. SEM images of the margins of suprastructure/implant couples were obtained before and after the electrochemical tests. Results: The OCP value of titanium became passive at the most negative potential. The lowest difference between the initial and constant OCP value was exhibited by the Au based suprastructure. Suprastructures made greater contributions to the potentiodynamic polarization curves of the implant/suprastructure couples. According to the ICP-MS results, Pd based and Au based couples dissolved less than Co-Ni based and Co-Cr based couples. Conclusions: Within the conditions this study, it may be concluded that the titanium implant forms a stable passive oxide layer in artificial saliva exposed to open air and does not affect the corrosion properties of the suprastructures. Pd based and Au based couples have been found to be more corrosion-resistant than base alloy couples.
引用
收藏
页码:467 / 475
页数:9
相关论文
共 30 条
  • [1] A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW
    ADELL, R
    LEKHOLM, U
    ROCKLER, B
    BRANEMARK, PI
    [J]. INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06): : 387 - 416
  • [2] The effect of pH on the corrosion of dental metal alloys
    Bayramoglu, G
    Alemdaroglu, T
    Kedici, S
    Aksüt, AA
    [J]. JOURNAL OF ORAL REHABILITATION, 2000, 27 (07) : 563 - 575
  • [3] MECHANICAL-PROPERTIES OF LASER-WELDED CAST AND WROUGHT TITANIUM
    BERG, E
    WAGNER, WC
    DAVIK, G
    DOOTZ, ER
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1995, 74 (03) : 250 - 257
  • [4] Bergman M, 1986, Int Dent J, V36, P41
  • [5] Certosimo Alfred J., 1996, General Dentistry, V44, P324
  • [6] Galvanic corrosion behavior of titanium implants coupled to dental alloys
    Cortada, M
    Giner, LL
    Costa, S
    Gil, FJ
    Rodríguez, D
    Planell, JA
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2000, 11 (05) : 287 - 293
  • [7] Geis-Gerstorfer J, 1989, Int J Oral Maxillofac Implants, V4, P119
  • [8] Effect of cast rectifiers on the marginal fit of UCLA abutments
    Gumieiro Jaime, Ana Paula
    de Vasconcellos, Diego Klee
    Melo Mesquita, Alfredo Mikail
    Kimpara, Estevao Tomomitsu
    Bottino, Marco Antonio
    [J]. JOURNAL OF APPLIED ORAL SCIENCE, 2007, 15 (03) : 169 - 174
  • [9] CORROSION TESTING BY POTENTIODYNAMIC POLARIZATION IN VARIOUS ELECTROLYTES
    HOLLAND, RI
    [J]. DENTAL MATERIALS, 1992, 8 (04) : 241 - 245
  • [10] Corrosion behaviour of dental metals and alloys in different media
    Kedici, SP
    Aksut, AA
    Kilicarslan, MA
    Bayramoglu, G
    Gokdemir, K
    [J]. JOURNAL OF ORAL REHABILITATION, 1998, 25 (10) : 800 - 808