Volar locking plate versus external fixation with optional additional K-wire for treatment of AO type C2/C3 fractures: a retrospective comparative study

被引:16
|
作者
Yu, Xiaofei [1 ,2 ]
Yu, Yadong [1 ,2 ]
Shao, Xinzhong [1 ,2 ]
Bai, Yanbin [1 ,2 ]
Zhou, Tong [1 ,2 ]
机构
[1] Hebei Med Univ, Hosp 3, Dept Hand Surg, 139 Ziqiang Rd, Shijiazhuang 050051, Hebei, Peoples R China
[2] Key Lab Biomech Hebei Prov, Shijiazhuang 050051, Hebei, Peoples R China
关键词
Unstable intra-articular fracture; Distal radius; Clinical outcome; Volar plate fixation; External fixation; DISTAL RADIUS FRACTURES; OPEN REDUCTION; DORSAL; COMPLICATIONS;
D O I
10.1186/s13018-019-1309-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThis study aimed to compare the radiographic and functional results of Arbeitsgemeinschaftfur Osteosynthesefragen (AO) type C2/C3 fracture of distal radius between volar locking plate (VLP) and external fixation (EF).MethodsIt was a retrospective comparative study. Between January 2015 and March 2018, a total of 62/117 patients who underwent EF (23) or VLP fixation (39) for AO type C2/C3 distal radius fractures were assessed. The follow-up period was at least 12months. Gartland-Werley scale and the disabilities of the arm, shoulder, and hand (DASH) scale were used to evaluate the overall functional outcomes; wrist range of motion and grip strength were measured. The radiographic parameters included radial inclination, volar tilt, radial length, ulnar variance, and articular step-off. All of the comparisons were performed using SPSS 21.0.ResultsThe mean follow-up time was 17.1months. At final visit, VLP performed better in wrist flexion (69.7 degrees vs 62.3 degrees, p<0.001), forearm pronation (73.1 degrees vs 64.8 degrees, p=0.027) and supination (70.6 degrees vs 63.1 degrees, p=0.033) than EF, but not different with regard to other kinematic parameters. No significant difference was found between two groups, in term of Gartland-Werley or DASH score (p>0.05). The ulnar variance and articular step-off was significantly more improved in VLP than EF group, being 0.6 vs 1.6mm (p=0.002) and 0.5 vs 1.2mm (p=0.007). The overall rate of complications did not differ in both groups (28.2% vs 34.5%) (p=0.587).ConclusionsCompared to EF, VLP fixation showed better performance in wrist mobility, correction of ulnar variance, and improving articular congruence, but with the comparable overall functional outcomes and complication rate.
引用
收藏
页数:8
相关论文
共 30 条
  • [21] Comparative study of the closed reduction percutaneous cannulated screw fixation and open reduction palmar locking plate fixation in the treatment of AO type A2 distal radius fractures
    Arel Gereli
    Ufuk Nalbantoglu
    Baris Kocaoglu
    Metin Turkmen
    Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 121 - 129
  • [22] Open reduction and plate fixation of displaced AO type C3 fractures of the distal radius: Restoration of articular congruity in eighteen cases
    Schneeberger, AG
    Ip, WY
    Poon, TL
    Chow, SP
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (05) : 350 - 357
  • [23] Letter Regarding "Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression"
    Spiegel, Adrian
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2016, 41 (07): : E225 - E225
  • [24] Surgical options for distal radius fractures of type C in elderly patients over 65 years old: a comparison of external fixation with Kirschner wires and volar locking plate
    He Zhang
    Man Liu
    Si-Yu Duan
    Hai-Rui Liang
    Rong-Da Xu
    Zhen-Cun Cai
    Journal of Orthopaedic Surgery and Research, 18
  • [25] Surgical options for distal radius fractures of type C in elderly patients over 65 years old: a comparison of external fixation with Kirschner wires and volar locking plate
    Zhang, He
    Liu, Man
    Duan, Si-Yu
    Liang, Hai-Rui
    Xu, Rong-Da
    Cai, Zhen-Cun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [26] Treatment of AO/OTA type 43-C3 pilon fractures with a combination of miniplate and main plate: a retrospective analysis
    Zhan, Junfeng
    Yang, Hu
    Huai, Chaoyue
    Yao, Yunfeng
    Xie, Yang
    Zhong, Qigang
    BMC SURGERY, 2025, 25 (01)
  • [27] Treatment of type C3 distal radius fracture resulted from high-energy injuries by volar plate in combination with external fixator
    Zhang Qiu-lin
    Zhu Xiao-dong
    Li Guo-dong
    Tang Hao
    Li Ming
    Wu Da-jiang
    CHINESE MEDICAL JOURNAL, 2009, 122 (13) : 1517 - 1520
  • [28] AO/OTA type C3 distal humeral fractures in patients aged 75 years and older: Is ORIF with double precontoured anatomical locking plates a reliable treatment?
    Aguado, Hector J.
    Mingo-Robinet, Juan
    Garcia-Virto, Virginia
    SanJose-Pardo, Inigo
    Pais, Sergio
    Alvarez-Ramos, Begona A.
    Simon-Perez, Clarisa
    Noriega, David C.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54
  • [29] Locking plate fixation versus antegrade nailing of 3-and 4-part proximal humerus fractures in patients without osteoporosis. Comparative retrospective study of 63 cases
    Boudard, G.
    Pomares, G.
    Milin, L.
    Lemonnier, I.
    Coudane, H.
    Mainard, D.
    Delagoutte, J. -P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (08) : 917 - 924
  • [30] Clinical Outcomes of Cannulated Screws versus Ring Pin versus K-Wire with Tension Band Fixation Techniques in the Treatment of Transverse Patellar Fractures: A Case-Control Study with Minimum 2-Year Follow-Up
    Liu, Junchuan
    Ge, Yiming
    Zhang, Guolei
    Zheng, Xuehong
    Gao, Liang
    Xing, Enzeng
    Lu, Jiangfeng
    Di, Jun
    Guo, Junfei