Image fusion of integrating fluoroscopy into 3D computed tomography in guidance of left atrial appendage closure

被引:22
作者
Mo, Bin-Feng [1 ]
Wan, Yi [1 ]
Alimu, Abudushalamu [1 ]
Sun, Jian [1 ]
Zhang, Peng-Pai [1 ]
Yu, Ying [1 ]
Chen, Mu [1 ]
Li, Wei [1 ]
Wang, Zhi-Quan [1 ]
Wang, Qun-Shan [1 ]
Li, Yi-Gang [1 ]
机构
[1] Shanghai Jiao Tong Univ, Xinhua Hosp, Sch Med, Dept Cardiol, 1665 Kong Jiang Rd, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
imaging fusion; left atrial appendage closure; computed tomography; fluoroscopy; transseptal puncture;
D O I
10.1093/ehjci/jez286
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims We evaluated the feasibility of left atrial appendage (LAA) closure guided by the image fusion of integrating fluoroscopy into 3D computed tomography (CT). Methods and results A total of 117 consecutive patients who underwent LAA closure with or without the image fusion were matched (1:2). Each LAA closure step of the Image fusion group was guided by the preprocedure CT and image fusion, especially in the plan of LAA measurement and transseptal puncture. All patients were successfully implanted with a WATCHMAN closure device. Comparing the two groups, the mean number of recapture times and the number of devices per patient of the Image fusion group were significantly lower (0.4 +/- 0.5 vs. 0.7 +/- 0.8, P = 0.031 and 1.0 +/- 0.2 vs. 1.1 +/- 0.3, P = 0.027, respectively). The one-time successful deployment rate by the support of the image fusion was higher than in the control group (66.7% vs. 44.9%, P = 0.026). Each case of the Image fusion group was completely occluded with one transseptal puncture, while five of the Non-image fusion group required redo transseptal punctures. During the 45-day follow-up, both group cases presented occlusion efficiency and no major adverse cardiac events were observed. Conclusion Image fusion technique integrating fluoroscopy into the 3D CT is safe and feasible which can be easily incorporated into the procedural work-flow of percutaneous LAA closure. The fusion image can play an important alternative role in the plan of LAA measurement and transseptal puncture site for improving the LAA closure procedure.
引用
收藏
页码:92 / 101
页数:10
相关论文
共 20 条
[11]   2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS [J].
Kirchhof, Paulus ;
Benussi, Stefano ;
Kotecha, Dipak ;
Ahlsson, Anders ;
Atar, Dan ;
Casadei, Barbara ;
Castella, Manuel ;
Diener, Hans-Christoph ;
Heidbuchel, Hein ;
Hendriks, Jeroen ;
Hindricks, Gerhard ;
Manolis, Antonis S. ;
Oldgren, Jonas ;
Popescu, Bogdan Alexandru ;
Schotten, Ulrich ;
Van Putte, Bart ;
Vardas, Panagiotis .
EUROPEAN HEART JOURNAL, 2016, 37 (38) :2893-+
[12]   EHRA/EAPCI expert consensus statement on catheter-based left atrial appendage occlusion [J].
Meier, Bernhard ;
Blaauw, Yuri ;
Khattab, Ahmed A. ;
Lewalter, Torsten ;
Sievert, Horst ;
Tondo, Claudio ;
Glikson, Michael .
EUROPACE, 2014, 16 (10) :1397-1416
[13]   Accuracy of Commonly-Used Imaging Modalities in Assessing Left Atrial Appendage for Interventional Closure: Review Article [J].
Morcos, Ramez ;
Al Taii, Haider ;
Bansal, Priya ;
Casale, Joel ;
Manam, Rupesh ;
Patel, Vikram ;
Cioci, Anthony ;
Kucharik, Michael ;
Malhotra, Arjun ;
Maini, Brijeshwar .
JOURNAL OF CLINICAL MEDICINE, 2018, 7 (11)
[14]   CT sizing for left atrial appendage closure is associated with favourable outcomes for procedural safety [J].
Rajwani, Adil ;
Nelson, Adam J. ;
Shirazi, Masoumeh G. ;
Disney, Patrick J. S. ;
Teo, Karen S. L. ;
Wong, Dennis T. L. ;
Young, Glenn D. ;
Worthley, Stephen G. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (12) :1361-1368
[15]   Novel integrated 3D multidetector computed tomography and fluoroscopy fusion for left atrial appendage occlusion procedures [J].
Roy, A. K. ;
Horvilleur, J. ;
Cormier, B. ;
Cazalas, M. ;
Fernandez, L. ;
Patane, M. ;
Neylon, A. ;
Spaziano, M. ;
Sawaya, F. J. ;
Arai, T. ;
Bouvier, E. ;
Hovasse, T. ;
Lefevre, T. ;
Chevalier, B. ;
Garot, P. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 (02) :322-329
[16]   Comparing Measurements of CT Angiography, TEE, and Fluoroscopy of the Left Atrial Appendage for Percutaneous Closure [J].
Saw, Jacqueline ;
Fahmy, Peter ;
Spencer, Ryan ;
Prakash, Roshan ;
McLaughlin, Patrick ;
Nicolaou, Savvas ;
Tsang, Michael .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (04) :414-422
[17]   Percutaneous left atrial appendage occlusion: the Munich consensus document on definitions, endpoints and data collection requirements for clinical studies [J].
Tzikas, Apostolos ;
Holmes, David R., Jr. ;
Gafoor, Sameer ;
Ruiz, Carlos E. ;
Blomstrom-Lundqvist, Carina ;
Diener, Hans-Christoph ;
Cappato, Riccardo ;
Kar, Saibal ;
Lee, Randal J. ;
Byrne, Robert A. ;
Ibrahim, Reda ;
Lakkireddy, Dhanunjaya ;
Soliman, Osama I. ;
Naebauer, Michael ;
Schneider, Steffen ;
Brachman, Johannes ;
Saver, Jeffrey L. ;
Tiemane, Klaus ;
Sievert, Horst ;
Camm, A. John ;
Lewalter, Thorsten .
EUROINTERVENTION, 2016, 12 (01) :103-111
[18]   Application of 3-Dimensional Computed Tomographic Image Guidance to WATCHMAN Implantation and Impact on Early Operator Learning Curve Single-Center Experience [J].
Wang, Dee Dee ;
Eng, Marvin ;
Kupsky, Daniel ;
Myers, Eric ;
Forbes, Michael ;
Rahman, Mehnaz ;
Zaidan, Mohammad ;
Parikh, Sachin ;
Wyman, Janet ;
Pantelic, Milan ;
Song, Thomas ;
Nadig, Jeff ;
Karabon, Patrick ;
Greenbaum, Adam ;
O'Neill, William .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (22) :2329-2340
[19]   Left Atrial Appendage Studied by Computed Tomography to Help Planning for Appendage Closure Device Placement [J].
Wang, Yan ;
Di Biase, Luigi ;
Horton, Rodney P. ;
Nguyen, Tuan ;
Morhanty, Prasant ;
Natale, Andrea .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (09) :973-982
[20]   Computed tomography measurement of the left atrial appendage for optimal sizing of the Watchman device [J].
Xu, Bo ;
Betancor, Jorge ;
Sato, Kimi ;
Harb, Serge ;
Rehman, Karim Abdur ;
Patel, Kunal ;
Kumar, Arnav ;
Cremer, Paul C. ;
Jaber, Wael ;
Rodriguez, L. Leonardo ;
Schoenhagen, Paul ;
Wazni, Oussama .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2018, 12 (01) :50-55