Image fusion of integrating fluoroscopy into 3D computed tomography in guidance of left atrial appendage closure

被引:22
作者
Mo, Bin-Feng [1 ]
Wan, Yi [1 ]
Alimu, Abudushalamu [1 ]
Sun, Jian [1 ]
Zhang, Peng-Pai [1 ]
Yu, Ying [1 ]
Chen, Mu [1 ]
Li, Wei [1 ]
Wang, Zhi-Quan [1 ]
Wang, Qun-Shan [1 ]
Li, Yi-Gang [1 ]
机构
[1] Shanghai Jiao Tong Univ, Xinhua Hosp, Sch Med, Dept Cardiol, 1665 Kong Jiang Rd, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
imaging fusion; left atrial appendage closure; computed tomography; fluoroscopy; transseptal puncture;
D O I
10.1093/ehjci/jez286
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims We evaluated the feasibility of left atrial appendage (LAA) closure guided by the image fusion of integrating fluoroscopy into 3D computed tomography (CT). Methods and results A total of 117 consecutive patients who underwent LAA closure with or without the image fusion were matched (1:2). Each LAA closure step of the Image fusion group was guided by the preprocedure CT and image fusion, especially in the plan of LAA measurement and transseptal puncture. All patients were successfully implanted with a WATCHMAN closure device. Comparing the two groups, the mean number of recapture times and the number of devices per patient of the Image fusion group were significantly lower (0.4 +/- 0.5 vs. 0.7 +/- 0.8, P = 0.031 and 1.0 +/- 0.2 vs. 1.1 +/- 0.3, P = 0.027, respectively). The one-time successful deployment rate by the support of the image fusion was higher than in the control group (66.7% vs. 44.9%, P = 0.026). Each case of the Image fusion group was completely occluded with one transseptal puncture, while five of the Non-image fusion group required redo transseptal punctures. During the 45-day follow-up, both group cases presented occlusion efficiency and no major adverse cardiac events were observed. Conclusion Image fusion technique integrating fluoroscopy into the 3D CT is safe and feasible which can be easily incorporated into the procedural work-flow of percutaneous LAA closure. The fusion image can play an important alternative role in the plan of LAA measurement and transseptal puncture site for improving the LAA closure procedure.
引用
收藏
页码:92 / 101
页数:10
相关论文
共 20 条
[1]   LAA Occluder View for post-implantation Evaluation (LOVE) - standardized imaging proposal evaluating implanted left atrial appendage occlusion devices by cardiac computed tomography [J].
Behnes, Michael ;
Akin, Ibrahim ;
Sartorius, Benjamin ;
Fastner, Christian ;
El-Battrawy, Ibrahim ;
Borggrefe, Martin ;
Haubenreisser, Holger ;
Meyer, Mathias ;
Schoenberg, Stefan O. ;
Henzler, Thomas .
BMC MEDICAL IMAGING, 2016, 16
[2]   Hybrid Imaging During Transcatheter Structural Heart Interventions [J].
Biaggi P. ;
Fernandez-Golfín C. ;
Hahn R. ;
Corti R. .
Current Cardiovascular Imaging Reports, 2015, 8 (9)
[3]   Transseptal Puncture Guided by CT-Derived 3D-Augmented Fluoroscopy [J].
Bourier, Felix ;
Reents, Tilko ;
Ammar-Busch, Sonia ;
Semmler, Verena ;
Telishevska, Marta ;
Kottmaier, Marc ;
Lennerz, Carsten ;
Grebmer, Christian ;
Kolb, Christof ;
Deisenhofer, Isabel ;
Hessling, Gabriele .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (03) :369-372
[4]   Initial Experience with a New Image Integration Module Designed for Reducing Radiation Exposure During Electrophysiological Ablation Procedures [J].
Cano, Oscar ;
Alonso, Pau ;
Osca, Joaquin ;
Andres, Ana ;
Sancho-Tello, Maria-Jose ;
Olaguee, Jose ;
Salvador, Antonio ;
Martinez-Dolz, Luis .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (06) :662-670
[5]  
Chow DHF, 2017, OPEN HEART, V4, DOI 10.1136/openhrt-2017-000627
[6]   Fluoroscopy integrated 3D mapping significantly reduces radiation exposure during ablation for a wide spectrum of cardiac arrhythmias [J].
Christoph, Marian ;
Wunderlich, Carsten ;
Moebius, Stefanie ;
Forkmann, Mathias ;
Sitzy, Judith ;
Salmas, Jozef ;
Mayer, Julia ;
Huo, Yan ;
Piorkowski, Christopher ;
Gaspar, Thomas .
EUROPACE, 2015, 17 (06) :928-937
[7]  
Glassy MS, 2018, CATHETER CARDIO INTE, P1
[8]   Left Atrial Appendage Closure as an Alternative to Warfarin for Stroke Prevention in Atrial Fibrillation A Patient-Level Meta-Analysis [J].
Holmes, David R., Jr. ;
Doshi, Shephal K. ;
Kar, Saibal ;
Price, Matthew J. ;
Sanchez, Jose M. ;
Sievert, Horst ;
Valderrabano, Miguel ;
Reddy, Vivek Y. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (24) :2614-2623
[9]  
Husain Z, 2017, SEMIN CARDIOTHORAC V, V21, P291, DOI 10.1177/1089253217714581
[10]   Left Atrial Appendage Closure Guided by Integrated Echocardiography and Fluoroscopy Imaging Reduces Radiation Exposure [J].
Jungen, Christiane ;
Zeus, Tobias ;
Balzer, Jan ;
Eickholt, Christian ;
Petersen, Margot ;
Kehmeier, Eva ;
Veulemans, Verena ;
Kelm, Malte ;
Willems, Stephan ;
Meyer, Christian .
PLOS ONE, 2015, 10 (10)