Retropulsion force in laser lithotripsy-an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser

被引:21
|
作者
Petzold, Ralf [1 ]
Miernik, Arkadiusz [1 ]
Suarez-Ibarrola, Rodrigo [1 ]
机构
[1] Univ Freiburg, Dept Urol, Fac Med, Med Ctr, Hugstetter Str 55, D-79106 Freiburg, Germany
关键词
Laser; Lithotripsy; Holmium; Thulium; Ho; YAG; Tm; Stone disease; Retropulsion; Repulsion; Propulsion;
D O I
10.1007/s00345-021-03668-8
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose To investigate retropulsion forces generated by two laser lithotripsy devices, a standard Ho:YAG and a new pulsed solid-state Thulium laser device. Materials and methods Two different Dornier laser devices were assessed: a Medilas H Solvo 35 and a pulsed solid-state Thulium laser evaluation model (Dornier MedTech Laser GmbH, Wessling, Germany). We used a 37 degrees C water bath; temperature was monitored with a thermocouple/data-logger. Representative sets of settings were examined for both devices, including short and long pulse lengths where applicable. For each setting, ten force values were recorded by a low-force precision piezo sensor whereby the laser fibre was either brought into contact with the sensor or placed at a 3 mm distance. Results The mean retropulsion forces resulting from the new Tm:YAG device were significantly lower than those of the Ho:YAG device under all pulse energy and frequency settings, ranging between 0.92 and 19.60 N for Thulium and 8.09-39.67 N for Holmium. The contact setups yielded lower forces than the distance setups. The forces increased with increasing pulse energy settings while shorter pulse lengths led to 12-44% higher retropulsive force in the 2.0 J/5 Hz comparisons. Conclusion The Tm:YAG device not only significantly generated lower retropulsion forces in all comparisons to Holmium at corresponding settings but also offers adjustment options to achieve lower energy pulses and longer pulse durations to produce even lower retropulsion. These advantages are a promising add-on to laser lithotripsy procedures and may be highly relevant for improving laser lithotripsy performance.
引用
收藏
页码:3651 / 3656
页数:6
相关论文
共 34 条
  • [31] Theoretical study on beam quality and thermal stability in solid-state zigzag tube laser amplifier
    Tian, Boyu
    Yu, Jiangchuan
    Zhang, Bin
    OPTICAL ENGINEERING, 2020, 59 (07)
  • [32] Percutaneous photoacoustic debulking of infra-inguinal atherosclerotic disease- early European experience with a novel, solid-state, pulsed -wave, ultraviolet 355 nm laser
    Kuczmik, Waclaw
    Oszkinis, Grzegorz
    Kruszyna, Lukasz
    Stanisic, Michal Goran
    Zelawski, Wojciech
    Kostecki, Jacek
    Planer, David
    Leon Jr, Luis R.
    Muncher, Yossi
    Cohen, Oshrat
    Topaz, On
    LASERS IN MEDICAL SCIENCE, 2025, 40 (01)
  • [33] The solid-state neck growth mechanisms in low energy laser sintering of gold nanoparticles: A molecular dynamics simulation study
    Pan, Heng
    Ko, Seung H.
    Grigoropoulos, Costas P.
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2008, 130 (09):
  • [34] Acute results, complications, and effect of lesion characteristics on outcome with the solid-state, pulsed-wave, mid-infrared laser angioplasty system: Final multicenter registry report
    Topaz, O
    McIvor, M
    Stone, GW
    Krucoff, MW
    Perin, EC
    Foschi, AE
    Sutton, J
    Nair, R
    deMarchena, E
    LASERS IN SURGERY AND MEDICINE, 1998, 22 (04) : 228 - 239