Retropulsion force in laser lithotripsy-an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser

被引:21
|
作者
Petzold, Ralf [1 ]
Miernik, Arkadiusz [1 ]
Suarez-Ibarrola, Rodrigo [1 ]
机构
[1] Univ Freiburg, Dept Urol, Fac Med, Med Ctr, Hugstetter Str 55, D-79106 Freiburg, Germany
关键词
Laser; Lithotripsy; Holmium; Thulium; Ho; YAG; Tm; Stone disease; Retropulsion; Repulsion; Propulsion;
D O I
10.1007/s00345-021-03668-8
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose To investigate retropulsion forces generated by two laser lithotripsy devices, a standard Ho:YAG and a new pulsed solid-state Thulium laser device. Materials and methods Two different Dornier laser devices were assessed: a Medilas H Solvo 35 and a pulsed solid-state Thulium laser evaluation model (Dornier MedTech Laser GmbH, Wessling, Germany). We used a 37 degrees C water bath; temperature was monitored with a thermocouple/data-logger. Representative sets of settings were examined for both devices, including short and long pulse lengths where applicable. For each setting, ten force values were recorded by a low-force precision piezo sensor whereby the laser fibre was either brought into contact with the sensor or placed at a 3 mm distance. Results The mean retropulsion forces resulting from the new Tm:YAG device were significantly lower than those of the Ho:YAG device under all pulse energy and frequency settings, ranging between 0.92 and 19.60 N for Thulium and 8.09-39.67 N for Holmium. The contact setups yielded lower forces than the distance setups. The forces increased with increasing pulse energy settings while shorter pulse lengths led to 12-44% higher retropulsive force in the 2.0 J/5 Hz comparisons. Conclusion The Tm:YAG device not only significantly generated lower retropulsion forces in all comparisons to Holmium at corresponding settings but also offers adjustment options to achieve lower energy pulses and longer pulse durations to produce even lower retropulsion. These advantages are a promising add-on to laser lithotripsy procedures and may be highly relevant for improving laser lithotripsy performance.
引用
收藏
页码:3651 / 3656
页数:6
相关论文
共 34 条
  • [1] Retropulsion force in laser lithotripsy—an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser
    Ralf Petzold
    Arkadiusz Miernik
    Rodrigo Suarez-Ibarrola
    World Journal of Urology, 2021, 39 : 3651 - 3656
  • [2] Temperature Assessment of a Novel Pulsed Thulium Solid-State Laser Compared with a Holmium:Yttrium-Aluminum-Garnet Laser
    Petzold, Ralf
    Suarez-Ibarrola, Rodrigo
    Miernik, Arkadiusz
    JOURNAL OF ENDOUROLOGY, 2021, 35 (06) : 853 - 859
  • [3] In VitroDusting Performance of a New Solid State Thulium Laser Compared to Holmium Laser Lithotripsy
    Petzold, Ralf
    Miernik, Arkadiusz
    Suarez-Ibarrola, Rodrigo
    JOURNAL OF ENDOUROLOGY, 2021, 35 (02) : 221 - 225
  • [4] Comparison of holmium:YAG and thulium fiber laser lithotripsy: ablation thresholds, ablation rates, and retropulsion effects
    Blackmon, Richard L.
    Irby, Pierce B.
    Fried, Nathaniel M.
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (07)
  • [5] In vitro fragmentation performance of a novel, pulsed Thulium solid-state laser compared to a Thulium fibre laser and standard Ho:YAG laser
    Kraft, Lea
    Petzold, Ralf
    Suarez-Ibarrola, Rodrigo
    Miernik, Arkadiusz
    LASERS IN MEDICAL SCIENCE, 2022, 37 (03) : 2071 - 2078
  • [6] Gas Bubble Anatomy During Laser Lithotripsy: An Experimental In Vitro Study of a Pulsed Solid-State Tm:YAG and Ho:YAG Device
    Petzold, Ralf
    Suarez-Ibarrola, Rodrigo
    Miernik, Arkadiusz
    JOURNAL OF ENDOUROLOGY, 2021, 35 (07) : 1051 - 1057
  • [7] In Vitro Comparison of Pulsed-Thulium:YAG, Holmium:YAG, and Thulium Fiber Laser
    Chicaud, Marie
    Kutchukian, Stessy
    Berthe, Laurent
    Corrales, Mariela
    Solano, Catalina
    Candela, Luigi
    Doizi, Steeve
    Smith, Daron
    Traxer, Olivier
    Panthier, Frederic
    JOURNAL OF ENDOUROLOGY, 2024, 38 (12) : 1427 - 1435
  • [8] Does the Novel Thulium Fiber Laser Have a Higher Risk of Urothelial Thermal Injury than the Conventional Holmium Laser in an In Vitro Study?
    Belle, Joshua D.
    Chen, Ricky
    Srikureja, Nathaniel
    Amasyali, Akin S.
    Keheila, Mohammed
    Baldwin, D. Duane
    JOURNAL OF ENDOUROLOGY, 2022, 36 (09) : 1249 - 1254
  • [9] Comparison of Single, Dual, and Staircase Temporal Pulse Profiles for Reducing Stone Retropulsion during Thulium Fiber Laser Lithotripsy in an In Vitro Stone Phantom Model
    Gonzalez, David A.
    Giglio, Nicholas C.
    Hall, Layton A.
    Vinnichenko, Viktoriya
    Fried, Nathaniel M.
    THERAPEUTICS AND DIAGNOSTICS IN UROLOGY 2019, 2019, 10852
  • [10] First Clinical Experience of a Novel Pulsed Solid-State Thulium:YAG Laser during Percutaneous Nephrolithotomy
    Bergmann, Julius
    Rosenbaum, Clemens Mathias
    Netsch, Christopher
    Gross, Andreas J. J.
    Becker, Benedikt
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (07)