To evaluate the efficacy of a gradient-echo sequence (3DFT-CISS) in the diagnosis of acoustic neuromas, two independent observers twice reviewed the images of the temporal bones of 83 patients. Contrast-enhanced T1-weighted spin echo images were used as the reference, showing 18 acoustic neuromas, including 5 purely intracanalicular and one intralabyrinthine tumours. High sensitivity (89-94 %), specificity (94-97 %) and accuracy (94-95 %) were found. Intraobserver (kappa 0.93-1) and interobserver (kappa 0.83-0.84) reproducibility were very good. The smallest intracanalicular tumour was overlooked twice by both observers; the intralabyrinthine tumour once by one observer. All tumours were detected with a less stringent decision criterion, at the expense of lower specificity.
引用
收藏
页码:593 / 598
页数:6
相关论文
共 23 条
[11]  
ENZMANN DR, 1987, AM J NEURORADIOL, V8, P99
[12]   THE BURDEN OF SCREENING FOR ACOUSTIC NEUROMA - ASYMMETRIC OTOLOGIC SYMPTOMS IN THE ENT CLINIC [J].
FISHER, EW ;
PARIKH, AA ;
HARCOURT, JP ;
WRIGHT, A .
CLINICAL OTOLARYNGOLOGY, 1994, 19 (01) :19-21
[13]  
Fukui MB, 1996, AM J NEURORADIOL, V17, P1211
[14]   NONNEOPLASTIC ENHANCING LESIONS MIMICKING INTRACANALICULAR ACOUSTIC NEUROMA ON GADOLINIUM-ENHANCED MR-IMAGES [J].
HAN, MH ;
JABOUR, BA ;
ANDREWS, JC ;
CANALIS, RF ;
CHEN, F ;
ANZAI, Y ;
BECKER, DP ;
LUFKIN, RB ;
HANAFEE, WN .
RADIOLOGY, 1991, 179 (03) :795-796
[15]  
Jackler RK, 1996, AM J NEURORADIOL, V17, P1226
[16]  
MARK AS, 1993, AM J NEURORADIOL, V14, P37
[17]  
MARSOTDUPUCH K, 1994, RADIOLOGY, V193, P321
[18]  
ROBSON AK, 1993, J ROY SOC MED, V86, P455
[19]  
SOULIE D, 1995, J RADIOL, V76, P93
[20]  
TELIAN SA, 1994, AM J OTOL, V15, P358