Enhancement of the detection sensitivity for volatile organic compounds by using an annular type photoionization detector and a pre-concentration system

被引:5
作者
Song, Kyuseok
Ahn, Bowha
Jung, Euochang
Lee, Yong-Ill
Ko, Sungsuk
机构
[1] Korea Atom Energy Res Inst, Nucl Chem Res Div, Taejon 305353, South Korea
[2] Changwon Univ, Dept Chem, Chang Won 641773, South Korea
[3] Sensor Tech Ltd, Songnam, South Korea
关键词
volatile organic compounds; photoionization detection; pre-concentration;
D O I
10.1016/j.aca.2006.09.066
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Photoionization detector (PID) was developed for a sensitive on-site detection of trace amounts of volatile organic compounds (VOCs) based on an annular type ion collection electrode assembly. An ion collector with an annular geometry could detect more stable ion signals in the PID system when compared to the other types of ion collectors when an UV lamp of 10.6 eV was used as an ionization source. In order to enhance the detection sensitivity, a pre-concentration system, which was developed by adopting a ceramic heater packed with rod shaped molecular sieves, was adopted for a detection of VOCs. The adopted ceramic heaters had a resistance of 10-20 Ohm, and the temperature of the heater was optimized by controlling the heating time of the resistor. The enhancement of the detection sensitivity was found to be 8-10 times with the PID system when compared to the signals measured without a pre-concentrator. The overall detection sensitivity of the developed PID system was estimated as 10 ppb or better. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:210 / 215
页数:6
相关论文
共 14 条
  • [1] AKIHIRO M, 2001, YOKOGAWA TECHNICAL R, V31, P1
  • [2] A method for carbon stable isotope analysis of methyl halides and chlorofluorocarbons at pptv concentrations
    Archbold, ME
    Redeker, KR
    Davis, S
    Elliot, T
    Kalin, RM
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (03) : 337 - 342
  • [3] Detection of the gasoline components methyl tert-butyl ether, benzene, toluene, and m-xylene using ion mobility spectrometers with a radioactive and UV ionization source
    Baumbach, JI
    Sielemann, S
    Xie, ZY
    Schmidt, H
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (06) : 1483 - 1490
  • [4] Coy JD, 2000, AM IND HYG ASSOC J, V61, P268, DOI 10.1202/0002-8894(2000)061<0268:FEOAPP>2.0.CO
  • [5] 2
  • [6] ENHANCED SELECTIVITY IN ION MOBILITY SPECTROMETRY ANALYSIS OF COMPLEX-MIXTURES BY ALTERNATE REAGENT GAS CHEMISTRY
    EICEMAN, GA
    WANG, YF
    GARCIAGONZALEZ, L
    HARDEN, CS
    SHOFF, DB
    [J]. ANALYTICA CHIMICA ACTA, 1995, 306 (01) : 21 - 33
  • [7] Ho C. K., 2001, SAND20010643 SAND NA
  • [8] Detection of volatile organic compounds using surface acoustic wave sensors with different polymer coatings
    Horrillo, MC
    Fernández, MJ
    Fontecha, JL
    Sayago, I
    García, M
    Aleixandre, M
    Santos, JP
    Arés, L
    Gutiérrez, J
    Gràcia, I
    Cané, C
    [J]. THIN SOLID FILMS, 2004, 467 (1-2) : 234 - 238
  • [9] MAIER I, 1988, J HIGH RES CHROMATOG, V83, P566
  • [10] Carbon nanotubes-based surface acoustic waves oscillating sensor for vapour detection
    Penza, M
    Antolini, F
    Vittori-Antisari, M
    [J]. THIN SOLID FILMS, 2005, 472 (1-2) : 246 - 252