Remote monitoring of cardiovascular implantable electronic devices

被引:0
作者
Sticherling, Christian [1 ]
Kuehne, Michael [1 ]
Schaer, Beat [1 ]
Altmann, David [1 ]
Osswald, Stefan [1 ]
机构
[1] Univ Basel Hosp, Div Cardiol, CH-4031 Basel, Switzerland
关键词
remote monitoring; implantable defibrillator; cardiac resynchronization therapy; telemedicine; CARDIOVERTER-DEFIBRILLATOR PATIENTS; HEART-FAILURE; CARDIAC RESYNCHRONIZATION; INTRATHORACIC IMPEDANCE; CLINICAL MANAGEMENT; FOLLOW-UP; GUIDELINES; PACEMAKERS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The number of patients implanted with cardiovascular electronic devices (CIED) like implantable defibrillators; (ICD), cardiac resynchrornisation (CRT) devices, and pacemakers continues to grow. These devices require regular follow-up interrogation in dedicated device clinics. Contemporary CIED are capable of wireless remote interrogation and monitoring. This technology has been proven to be technically reliable and helpful in certain conditions. It is of particular benefit in monitoring devices that are under a safety alert since it allows early identification of device malfunction and minimises the risk of under-reporting. There is also strong evidence that it helps to reduce heart failure hospitalisations in CRT and ICD patients. Furthermore, this technology proves to be very helpful in the early detection of arrhythmias like atrial fibrillation or ventricular tachyarrhythmias. Remote monitoring significantly reduces the number of follow-up visits, patients' and physicians' time spent per visit, and increases patients' adherence to follow-up visits. Future studies are needed to determine how to best allocate this new technology in a cost-effective manner.
引用
收藏
页码:596 / 601
页数:6
相关论文
共 31 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[2]  
Ammann P, 2004, SWISS MED WKLY, V134, P277
[3]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[4]   Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure - The COMPASS-HF study [J].
Bourge, Robert C. ;
Abraham, William T. ;
Adamson, Philip B. ;
Aaron, Mark F. ;
Aranda, Juan M., Jr. ;
Magalski, Anthony ;
Zile, Michael R. ;
Smith, Andrew L. ;
Smart, Frank W. ;
O'Shaughnessy, Mark A. ;
Jessup, Mariell L. ;
Sparks, Brandon ;
Naftel, David L. ;
Stevenson, Lynne Warner .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (11) :1073-1079
[5]   Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators [J].
Burri, Haran ;
Senouf, David .
EUROPACE, 2009, 11 (06) :701-709
[6]   Monitoring Intrathoracic Impedance with an Implantable Defibrillator Reduces Hospitalizations in Patients with Heart Failure [J].
Catanzariti, Domenico ;
Lunati, Maurizio ;
Landolina, Maurizio ;
Zanotto, Gabriele ;
Lonardi, Gabriele ;
Iacopino, Saverio ;
Oliva, Fabrizio ;
Perego, Giovanni B. ;
Varbaro, Annamaria ;
Denaro, Alessandra ;
Valsecchi, Sergio ;
Vergara, Giuseppe .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (03) :363-370
[7]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549
[8]   Electrical storm in patients with transvenous implantable cardioverter-defibrillators - Incidence, management and prognostic implications [J].
Credner, SC ;
Klingenheben, T ;
Mauss, O ;
Sticherling, C ;
Hohnloser, SH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) :1909-1915
[9]   ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2008 [J].
Dickstein, Kenneth ;
Cohen-Solal, Alain ;
Filippatos, Gerasimos ;
McMurray, John J. V. ;
Ponikowski, Piotr ;
Poole-Wilson, Philip Alexander ;
Stromberg, Anna ;
van Veldhuisen, Dirk J. ;
Atar, Dan ;
Hoes, Arno W. ;
Keren, Andre ;
Mebazaa, Alexandre ;
Nieminen, Markku ;
Priori, Silvia Giuliana ;
Swedberg, Karl .
EUROPEAN HEART JOURNAL, 2008, 29 (19) :2388-2442
[10]   Necessity for surgical revision of defibrillator leads implanted long-term causes and management [J].
Eckstein, Jens ;
Koller, Michael T. ;
Zabel, Markus ;
Kalusche, Dietrich ;
Schaer, Beat A. ;
Osswald, Stefan ;
Sticherling, Christian .
CIRCULATION, 2008, 117 (21) :2727-2733