High-temporospatial-resolution dynamic contrast-enhanced (DCE) wrist MRI with variable-density pseudo-random circular Cartesian undersampling (CIRCUS) acquisition: evaluation of perfusion in rheumatoid arthritis patients

被引:15
作者
Liu, Jing [1 ]
Pedoia, Valentina [1 ]
Heilmeier, Ursula [1 ]
Ku, Eric [1 ]
Su, Favian [1 ]
Khanna, Sameer [2 ]
Imboden, John [3 ]
Graf, Jonathan [3 ]
Link, Thomas [1 ]
Li, Xiaojuan [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Univ Calif Berkeley, Berkeley, CA 94720 USA
[3] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
关键词
rheumatoid arthritis; perfusion; neovascularization; synovitis; dynamic contrast enhanced; acceleration; undersampling; compressed sensing; DISEASE-ACTIVITY; BONE EDEMA; METHOTREXATE; SYNOVITIS; RECONSTRUCTION; INFLAMMATION; COMBINATION; MULTICENTER; SENSITIVITY;
D O I
10.1002/nbm.3443
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study is to evaluate highly accelerated three-dimensional (3D) dynamic contrast-enhanced (DCE) wrist MRI for assessment of perfusion in rheumatoid arthritis (RA) patients. A pseudo-random variable-density undersampling strategy, circular Cartesian undersampling (CIRCUS), was combined with k-t SPARSE-SENSE reconstruction to achieve a highly accelerated 3D DCE wrist MRI. Two healthy volunteers and 10 RA patients were studied. Two patients were on methotrexate (MTX) only (Group I) and the other eight were treated with a combination therapy of MTX and anti-tumor necrosis factor (TNF) therapy (Group II). Patients were scanned at baseline and 3month follow-up. DCE MR images were used to evaluate perfusion in synovitis and bone marrow edema pattern in the RA wrist joints. A series of perfusion parameters was derived and compared with clinical disease activity scores of 28 joints (DAS28). 3D DCE wrist MR images were obtained with a spatial resolution of 0.3x0.3x1.5mm(3) and temporal resolution of 5s (with an acceleration factor of 20). The derived perfusion parameters, most notably transition time (dT) of synovitis, showed significant negative correlations with DAS28-ESR (r=-0.80, p<0.05) and DAS28-CRP (r=-0.87, p<0.05) at baseline and also correlated significantly with treatment responses evaluated by clinical score changes between baseline and 3month follow-up (with DAS28-ESR r=-0.79, p<0.05, and DAS28-CRP r=-0.82, p<0.05). Highly accelerated 3D DCE wrist MRI with improved temporospatial resolution has been achieved in RA patients and provides accurate assessment of neovascularization and perfusion in RA joints, showing promise as a potential tool for evaluating treatment responses. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:15 / 23
页数:9
相关论文
共 44 条
  • [1] Beckers C, 2004, J NUCL MED, V45, P956
  • [2] Correlation between computer-aided dynamic gadolinium-enhanced MRI assessment of inflammation and semi-quantitative synovitis and bone marrow oedema scores of the wrist in patients with rheumatoid arthritis-a cohort study
    Boesen, Mikael
    Kubassova, Olga
    Bouert, Rasmus
    Axelsen, Mette B.
    Ostergaard, Mikkel
    Cimmino, Marco A.
    Danneskiold-Samsoe, Bente
    Horslev-Petersen, Kim
    Bliddal, Henning
    [J]. RHEUMATOLOGY, 2012, 51 (01) : 134 - 143
  • [3] The PREMIER study - A multicenter, randomized, double-blind clinical trial of combination therapy with adalimumab plus methotrexate versus methotrexate alone or adalimumab alone in patients with early, aggressive rheumatoid arthritis who had not had previous methotrexate treatment
    Breedveld, FC
    Weisman, MH
    Kavanaugh, AF
    Cohen, SB
    Pavelka, K
    van Vollenhoven, R
    Sharp, J
    Perez, JL
    Spencer-Green, GT
    [J]. ARTHRITIS AND RHEUMATISM, 2006, 54 (01): : 26 - 37
  • [4] Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information
    Candès, EJ
    Romberg, J
    Tao, T
    [J]. IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) : 489 - 509
  • [5] Near-optimal signal recovery from random projections: Universal encoding strategies?
    Candes, Emmanuel J.
    Tao, Terence
    [J]. IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (12) : 5406 - 5425
  • [6] Cimmino MA, 2014, CLIN EXP RHEUMATOL, V32, P647
  • [7] Compressed sensing
    Donoho, DL
    [J]. IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (04) : 1289 - 1306
  • [8] Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE
    Feng, Li
    Srichai, Monvadi B.
    Lim, Ruth P.
    Harrison, Alexis
    King, Wilson
    Adluru, Ganesh
    Dibella, Edward V. R.
    Sodickson, Daniel K.
    Otazo, Ricardo
    Kim, Daniel
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) : 64 - 74
  • [9] Fransen J, 2005, CLIN EXP RHEUMATOL, V23, pS93
  • [10] Quantitative assessment of the rheumatoid synovial microvascular bed by gadolinium-DTPA enhanced magnetic resonance imaging
    Gaffney, K
    Cookson, J
    Blades, S
    Coumbe, A
    Blake, D
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 1998, 57 (03) : 152 - 157