A sensitivity study of a hybrid photovoltaic/thermal water-heating system with natural circulation

被引:225
作者
Ji, Jie [1 ]
Lu, Jian-Ping
Chow, Tin-Tai
He, Wei
Pei, Gang
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Anhui, Peoples R China
[2] City Univ Hong Kong, Div Bldg Sci & Technol, Kowloon, Hong Kong, Peoples R China
关键词
hybrid photovoltaic/thermal (PV/T) water-heating system; PV-cell covering factor; total efficiency; primary-energy saving; hot-water load per unit heat-collecting area; transmissivity;
D O I
10.1016/j.apenergy.2006.04.009
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A flat-box aluminum-alloy photovoltaic and water-heating system designed for natural circulation was constructed. The hybrid photovoltaic/thermal (PV/T) collector was an integration of single-crystalline silicon cells into a solar thermal collector. The product was able to generate electricity and hot water simultaneously. Outdoor tests on an improved prototype were conducted in a moderate climate zone. Then dynamic simulation runs, using a validated numerical model, were performed. These included sensitivity tests with variations of the system water mass, PV cell covering factor, and front glazing transmissivity. The test results showed that the characteristic daily primary-energy saving could reach up to 65% for this system with a PV cell covering factor 0.63 and front glazing transmissivity of 0.83, when the hot water load per unit heat-collecting area exceeded 80 kg/m(2). The simulated results indicated that the higher the PV cell covering factor and the glazing transmissivity, the better the overall system performance. The effects were quantified. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:222 / 237
页数:16
相关论文
共 15 条
[1]   Model calculations on a flat-plate solar heat collector with integrated solar cells [J].
Bergene, T ;
Lovvik, OM .
SOLAR ENERGY, 1995, 55 (06) :453-462
[2]   Hybrid photovoltaic-thermosyphon water heating system for residential application [J].
Chow, TT ;
He, W ;
Ji, J .
SOLAR ENERGY, 2006, 80 (03) :298-306
[3]   Performance analysis of photovoltaic-thermal collector by explicit dynamic model [J].
Chow, TT .
SOLAR ENERGY, 2003, 75 (02) :143-152
[4]   EXTENSION OF THE HOTTEL-WHILLIER MODEL TO THE ANALYSIS OF COMBINED PHOTOVOLTAIC THERMAL FLAT-PLATE COLLECTORS [J].
FLORSCHUETZ, LW .
SOLAR ENERGY, 1979, 22 (04) :361-366
[5]  
GARG HP, P 1989 C ISES, V1, P701
[6]  
GE XS, 1908, SOLAR ENERGY ENG FUN, P245
[7]   Hybrid photovoltaic and thermal solar-collector designed for natural circulation of water [J].
He, W ;
Chow, TT ;
Ji, J ;
Lu, JP ;
Pei, G ;
Chan, LS .
APPLIED ENERGY, 2006, 83 (03) :199-210
[8]   Performance evaluation of solar photovoltaic/thermal systems [J].
Huang, BJ ;
Lin, TH ;
Hung, WC ;
Sun, FS .
SOLAR ENERGY, 2001, 70 (05) :443-448
[9]  
HUANG BJ, 1991, ASME, V113, P172
[10]  
MCCABE J, P SOL 2004 C ISCE 04