Indoor Environmental Quality Assessment and Occupant Satisfaction: A Post-Occupancy Evaluation of a UAE University Office Building

被引:20
作者
Kim, Young Ki [1 ]
Abdou, Yasmin [1 ]
Abdou, Alaa [2 ]
Altan, Hasim [3 ]
机构
[1] United Arab Emirates Univ, Dept Architectural Engn, Al Ain 15551, U Arab Emirates
[2] Ajman Univ, Dept Architecture, Ajman 346, U Arab Emirates
[3] Arkin Univ Creat Arts & Design, Dept Architecture, CY-99300 Kyrenia, Cyprus
关键词
indoor environment quality; post-occupancy evaluation; occupant satisfaction; indoor air quality; university office building; hot arid climate; EXTREME-WEATHER-EVENTS; CLIMATE-CHANGE; AIR-QUALITY; HEALTH; PRODUCTIVITY; VENTILATION; POLLUTANTS; PERCEPTION; SYMPTOMS; COMFORT;
D O I
10.3390/buildings12070986
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As occupants spend almost 90% of their day indoors, especially in the workplaces, Indoor Environmental Quality (IEQ) plays a primary role in health and wellbeing, productivity, and building energy consumption. Adopting the IEQ and Post-Occupancy Evaluation (POE), data has been gathered from nine multilevel open offices within a university building located in Al Ain, in the United Arab Emirates (UAE) for three winter months. Physical parameters were monitored using data loggers to record the main IEQ factors. In parallel, POE questionnaires have been distributed to obtain occupants' satisfaction with the IEQ and health-related symptoms experienced in the workspaces. The IEQ and POE data have shown slightly above or below the recommended ranges with the occupants similarly and slightly dissatisfied with the building. The thermal comfort revealed concerns with 99% of temperatures below international standards where 55% of the survey respondents reported "too cold". The IAQ measurements showed 45% and 30% of the respondents reporting "stuffy air" and "headache" which indicated symptoms that could be tracked to other parameters or a combination of several, and the findings have been discussed in detail in this paper. This research contributed to identifying correlations between measured data and occupant satisfaction and identifying common IEQ defects and their sources to better communicate with facility managers and architects.
引用
收藏
页数:26
相关论文
共 49 条
[1]  
Abdou A., 2016, POSTOCCUPANCY EVALUA
[2]  
Abdou A, 2017, P 5 ANN INT C ARCHIT
[3]  
Adamkiewicz G., 2010, WHO guidelines for indoor air quality: selected pollutants
[4]   Occupant productivity and office indoor environment quality: A review of the literature [J].
Al Horr, Yousef ;
Arif, Mohammed ;
Kaushik, Amit ;
Mazroei, Ahmed ;
Katafygiotou, Martha ;
Elsarrag, Esam .
BUILDING AND ENVIRONMENT, 2016, 105 :369-389
[5]  
Aries M.B.C., 2009, HERON, V54, P49
[6]  
Bluyssen P.M, 2009, INDOOR ENV HDB MAKE
[7]   Designing activity-based workspaces: satisfaction, productivity and physical activity [J].
Candido, Christhina ;
Thomas, Leena ;
Haddad, Shamila ;
Zhang, Fan ;
Mackey, Martin ;
Ye, Wei .
BUILDING RESEARCH AND INFORMATION, 2019, 47 (03) :275-289
[8]   Thermal comfort and behavioural strategies in office buildings located in a hot-arid climate [J].
Cena, K ;
de Dear, R .
JOURNAL OF THERMAL BIOLOGY, 2001, 26 (4-5) :409-414
[9]   Indoor Air Quality and Health [J].
Cincinelli, Alessandra ;
Martellini, Tania .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2017, 14 (11)
[10]  
Clements-Croome D., 2000, P HLTH BUILDINGS, V1, P629