The Changes in Pulse Pressure Variation or Stroke Volume Variation After a "Tidal Volume Challenge" Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation

被引:150
作者
Myatra, Sheila Nainan [1 ]
Prabu, Natesh R. [1 ]
Vasishtha, Jigeeshu [1 ]
Monnet, Xavier [2 ]
Kulkarni, Atul Prabhakar [1 ]
Teboul, Jean-Louis [2 ]
机构
[1] Tata Mem Hosp, Dept Anesthesiol Crit Care & Pain, Bombay, Maharashtra, India
[2] Hop Bicetre, Hop Univ Paris Sud, AP HP, Serv Reanimat Med, Le Kremlin Bicetre, France
关键词
end-expiratory occlusion test; fluid responsiveness; low tidal volume; pulse pressure variation; stoke volume variation; tidal volume challenge; END-EXPIRATORY OCCLUSION; CRITICALLY-ILL PATIENTS; SEPTIC PATIENTS; VARIABLES; CARE;
D O I
10.1097/CCM.0000000000002183
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Stroke volume variation and pulse pressure variation do not reliably predict fluid responsiveness during low tidal volume ventilation. We hypothesized that with transient increase in tidal volume from 6 to 8 mL/kg predicted body weight, that is, "tidal volume challenge;' the changes in pulse pressure variation and stroke volume variation will predict fluid responsiveness. Design: Prospective, single-arm study. Setting: Medical-surgical ICU in a university hospital. Patients: Adult patients with acute circulatory failure, having continuous cardiac output monitoring, and receiving controlled low tidal volume ventilation. Interventions: The pulse pressure variation, stroke volume variation, and cardiac index were recorded at tidal volume 6 mL/ kg predicted body weight and 1 minute after the "tidal volume challenge:' The tidal volume was reduced back to 6 mL/kg predicted body weight, and a fluid bolus was given to identify fluid responders (increase in cardiac index > 15%). The end-expiratory occlusion test was performed at tidal volumes 6 and 8 mL/ kg predicted body weight and after reducing tidal volume back to 6 mL/kg predicted body weight. Results: Thirty measurements were obtained in 20 patients. The absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mUkg predicted body weight predicted fluid responsiveness with areas under the receiver operating characteristic curves (with 95% CIs) being 0.99 (0.98-1.00) and 0.97 (0.92-1.00), respectively. The best cutoff values of the absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mUkg predicted body weight were 3.5% and 2.5%, respectively. The pulse pressure variation, stroke volume variation, central venous pressure, and end-expiratory occlusion test obtained during tidal volume 6 mUkg predicted body weight did not predict fluid responsiveness. Conclusions: The changes in pulse pressure variation or stroke volume variation obtained by transiently increasing tidal volume (tidal volume challenge) are superior to pulse pressure variation and stroke volume variation in predicting fluid responsiveness during low tidal volume ventilation.
引用
收藏
页码:415 / 421
页数:7
相关论文
共 30 条
[1]   A positive fluid balance is an independent prognostic factor in patients with sepsis [J].
Acheampong, Angela ;
Vincent, Jean-Louis .
CRITICAL CARE, 2015, 19
[2]   Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. [J].
Brower, RG ;
Matthay, MA ;
Morris, A ;
Schoenfeld, D ;
Thompson, BT ;
Wheeler, A ;
Wiedemann, HP ;
Arroliga, AC ;
Fisher, CJ ;
Komara, JJ ;
Perez-Trepichio, P ;
Parsons, PE ;
Wolkin, R ;
Welsh, C ;
Fulkerson, WJ ;
MacIntyre, N ;
Mallatratt, L ;
Sebastian, M ;
McConnell, R ;
Wilcox, C ;
Govert, J ;
Thompson, D ;
Clemmer, T ;
Davis, R ;
Orme, J ;
Weaver, L ;
Grissom, C ;
Eskelson, M ;
Young, M ;
Gooder, V ;
McBride, K ;
Lawton, C ;
d'Hulst, J ;
Peerless, JR ;
Smith, C ;
Brownlee, J ;
Pluss, W ;
Kallet, R ;
Luce, JM ;
Gottlieb, J ;
Elmer, M ;
Girod, A ;
Park, P ;
Daniel, B ;
Gropper, M ;
Abraham, E ;
Piedalue, F ;
Glodowski, J ;
Lockrem, J ;
McIntyre, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (18) :1301-1308
[3]   The influence of tidal volume on the dynamic variables of fluid responsiveness in critically III patients [J].
Charron, C ;
Fessenmeyer, C ;
Cosson, C ;
Mazoit, JX ;
Hebert, JL ;
Benhamou, D ;
Edouard, AR .
ANESTHESIA AND ANALGESIA, 2006, 102 (05) :1511-1517
[4]   Pulse pressure variations to predict fluid responsiveness: influence of tidal volume [J].
De Backer, D ;
Heenen, S ;
Piagnerelli, M ;
Koch, M ;
Vincent, JL .
INTENSIVE CARE MEDICINE, 2005, 31 (04) :517-523
[5]   Can one predict fluid responsiveness in spontaneously breathing patients? [J].
De Backer, Daniel ;
Pinsky, Michael R. .
INTENSIVE CARE MEDICINE, 2007, 33 (07) :1111-1113
[6]  
DELLINGER RP, 2013, INTENS CARE MED, V39, P165, DOI DOI 10.1007/s00134-012-2769-8
[7]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[8]   Arterial pulse pressure variation suitability in critical care: A French national survey [J].
Fischer, Marc-Olivier ;
Mahjoub, Yazine ;
Boisselier, Clement ;
Tavernier, Benoit ;
Dupont, Herve ;
Leone, Marc ;
Lefrant, Jean-Yves ;
Gerard, Jean-Louis ;
Hanouz, Jean-Luc ;
Fellahi, Jean-Luc .
ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2015, 34 (01) :23-28
[9]   Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies [J].
Freitas, F. G. R. ;
Bafi, A. T. ;
Nascente, A. P. M. ;
Assuncao, M. ;
Mazza, B. ;
Azevedo, L. C. P. ;
Machado, F. R. .
BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (03) :402-408
[10]  
Hong JQ, 2014, SAUDI MED J, V35, P261