A Practical Two-level Automatic Voltage Control System: Design and Field Experience

被引:0
作者
Shi, Bolong [1 ]
Wu, Chang [2 ]
Sun, Weizhen [1 ]
Bao, Wei [3 ]
Guo, Ruipeng [4 ]
机构
[1] Zhejiang Power Dispatch & Telecommun Ctr, Hangzhou 310007, Zhejiang, Peoples R China
[2] Quzhou Power Dispatch & Telecommun Ctr, Quzhou 324000, Zhejiang, Peoples R China
[3] Hangzhou Worui Power Technol & Sci Co Ltd, Inst Dept, Hangzhou 310027, Zhejiang, Peoples R China
[4] Zhejiang Univ, Sch Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
来源
2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) | 2018年
关键词
Automatic Voltage Control; Branch and Bound Method; Corrective Voltage Control; Reactive Optimal Power Flow; State Estimation; SECONDARY;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A practical two-level system-wide automatic voltage control (AVC) system has been developed, implemented and installed in a close-loop manner at several power systems. The architecture of this two-level system-wide AVC system is different from the traditional three-level hierarchical structure in that it is implemented centralized. Compared to three-level hierarchical structure, one distinguished feature of the two-level AVC system is that it does not require the need of performing zone division and it adapts to structural changes in network topologies. Another feature of the two-level AVC system is that it works even when the state estimation (SE) function at the underlying control center fails. To achieve a close-loop automatic voltage control, the two-level AVC system is equipped with two high-performance optimization-based voltage control modules: a reactive optimal power flow (ROPF) module and a corrective voltage control (CVC) module. In designing the AVC system, some domain knowledge and engineering judgments were developed and integrated in the overall solution method. At present, the two-level AVC system has been commissioned and put into a close-loop mode at three provincial power grids in China. The performance of the two-level system-wide AVC system has been very encouraging. This paper also describes some field performance of the AVC system.
引用
收藏
页码:1397 / 1407
页数:11
相关论文
共 21 条
[1]   Adaptive voltage control strategy for variable-speed wind turbine connected to a weak network [J].
Abulanwar, Sayed ;
Hu, Weihao ;
Chen, Zhe ;
Iov, Florin .
IET RENEWABLE POWER GENERATION, 2016, 10 (02) :238-249
[2]  
[Anonymous], INT PRACT REACT POW
[3]  
[Anonymous], P 1988 CIGRE PAR FRA
[4]  
[Anonymous], 2009, 2009 IEEE POW EN SOC
[5]  
[Anonymous], IEEE T POWER SYSTEMS
[6]  
[Anonymous], POW SYST COMP C
[7]  
[Anonymous], IEEE T POWER SYSTEMS
[8]   The coordinated automatic voltage control of the Italian transmission grid - Part II: Control apparatuses and field performance of the consolidated hierarchical system [J].
Corsi, S ;
Pozzi, M ;
Sforna, M ;
Dell'Olio, G .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2004, 19 (04) :1733-1741
[9]  
CORSI S, 1995, IEEE T POWER SYST, V10, P686, DOI 10.1109/59.387904
[10]  
Feng YS, 2016, ASIA-PAC POWER ENERG, P278, DOI 10.1109/APPEEC.2016.7779512